Elmo Rietschle C-VLU 62
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle C-VLU 62

Elmo Rietschle C-VLU 62 — Claw Vacuum Pumps.

The C-VLU 62 is a dry-running claw vacuum pump with contact-free rotors synchronized by an oil-lubricated gear pair, available in standard CD and corrosion-protected XD versions. It delivers 65 m³/h suction capacity at 50 Hz and operates continuously between 700 mbar and 40 mbar (abs.), distinguishing it from larger siblings like the C-VLU 301 and 401. Its oil-free compression chamber and integral non-return valve make it suitable for dry processes requiring clean vacuum and backflow protection.

Elmo Rietschle C-VLU Series — Model Comparison & Selection

Model Max inlet pressure, kPaOperating principlePumping speed, m³/hUltimate pressure, mbarAmbient temperature limit, °C
C-VLU 62 Current —————
C-VLU 301 70Klauen-Vakuumpumpe265305
C-VLU 401 —————

Full specifications

Description

Construction and Series Positioning

Behavior Under Load and Media

Installation, Connection, and Operation

Integration & Operating Notes

Process Limits
Exhaust back pressure must not exceed +30 mbar

Higher back pressure can cause overload, increased motor current, and potential mechanical damage. Exhaust lines should be sized with low resistance and routed to avoid restrictions; if process back pressure exceeds +30 mbar, contact the manufacturer for alternative solutions.

Operating Instructions BA 891-EN, Chapter 2.4 / 5.3, pages 8 and 18
Electrical
Verify counter-clockwise rotation before continuous operation

Wrong rotation direction can damage the pump and cause injury. Use a phase sequence indicator and briefly start the motor (max. 2 seconds) to confirm rotation is counter-clockwise when viewed at the motor blower. Correct wiring at the terminal box if needed.

Operating Instructions BA 891-EN, Chapter 6.1.2, page 21
Electrical
Motors above certain ratings require assisted starting

Motors with AC apparent output >1.7 kVA, three-phase >5.2 kVA, or start currents >60 A are not designed for direct-on-line start. Use star-delta, soft starter, or frequency converter to limit starting torque and mechanical load. Verify motor data plate against supply.

Operating Instructions BA 891-EN, Chapter 5.5.1, page 19
Environment
Ambient and inlet temperature must remain between 5 °C and 40 °C

Temperatures outside this range can affect lubrication, motor cooling, and material integrity. Ensure installation location has adequate ventilation and does not draw in hot exhaust air from other machines. For operation outside this range, consult manufacturer.

Operating Instructions BA 891-EN, Chapter 2.4 / 5.2, pages 8 and 17
Environment
Output reduction noticeable above 1000 m altitude

At elevations above 1000 m, reduced air density affects cooling and pumping performance. Contact manufacturer for installations above 1000 m to ensure proper sizing and cooling.

Operating Instructions BA 891-EN, Chapter 5.2, page 18
Control & I/O
Integrate pump into plant emergency stop concept

The vacuum pump does not have its own Emergency Stop or Emergency Off. The operator must integrate it into the plant's protection concept to provide emergency stop/off functionality, ensuring safe shutdown in case of process upset.

Operating Instructions BA 891-EN, Chapter 2.12, page 11

Selection & Integration Q&A

When should I choose the C-VLU 62 over the C-VLU 301 or C-VLU 401?

Choose C-VLU 62 for suction capacities around 65 m³/h at 50 Hz and continuous inlet pressures between 40 and 700 mbar (abs.). The C-VLU 301 offers 265 m³/h for higher flow; the C-VLU 401 is even larger. Select based on required pumping speed and operating pressure range.

What are the requirements for connecting the C-VLU 62 to my process piping and exhaust?

Remove blind plugs/adhesive film from vacuum and exhaust connections. Connect pipes without excessive force or torque. The exhaust opening must not be closed or restricted; maximum permissible back pressure is +30 mbar. Ensure all connections are leak-tight and screw/flange connections are tight.

What are the mounting and duty-cycle limitations for the C-VLU 62?

Install horizontally with max. 8° inclination, secure against tipping, and allow 50 cm maintenance space. Ambient/inlet temperature 5–40 °C. Avoid frequent switching (≈10 times/hour) as it may overheat motor; for such duty consult manufacturer. Above 1000 m altitude, output reduces.

What maintenance items and accessories are not included with the base pump?

The base delivery does not include intake filter (optional paper or polyester), motor protection switch (user-supplied), main switch (user-supplied), or condensate drain accessories for XD. Spare parts are listed in the separate Spare Parts List. Regular maintenance includes gearbox oil changes and oil level checks; if an optional intake filter is fitted, clean or replace its filter element as needed.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — vacuum pump (BA 891-EN, ed. 1.0 08.04.2024, EN)
Manual ·1,5 МБ ·34 pp.
View PDF
PDF
Spare Parts List — vacuum pump (ed. 1.0 13.12.2024, EN)
Spare parts ·1,1 МБ ·11 pp.
View PDF