Elmo Rietschle L-2BV 3151
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle L-2BV 3151

Elmo Rietschle L-2BV 3151 — Liquid Ring Vacuum Pumps with Max inlet pressure 110 kPa, Pumping speed 39 m³/h.

The L-2BV 3151 is a liquid-ring vacuum pump/compressor in the L-2BV series, factory-rated for vacuum operation to 110 kPa abs. and compressor duty to 300 kPa abs. Its 0.65 l/min nominal operating-liquid flow and 0.200 l standstill fill distinguish this modification from larger siblings such as the L-2BV 7060. It serves as a compact, self-priming vacuum source for processes tolerating a 5 kPa abs. lower limit without cavitation protection.

Max inlet pressure
110 kPa
Pumping speed
39 m³/h

Elmo Rietschle L-2BV Series — Model Comparison & Selection

Model Max inlet pressure, kPaOperating principleWeight, kgNoise level, dBOperating temperature, °CPumping speed, m³/h
L-2BV 3151 Current 3.3—97011039
2BV3151 —Liquid ring vacuum pump970——
L-2BV 7060 130liquid-ring257080—

Full specifications

Core Performance & Functional Specifications
Max inlet pressure 3.3 kPa
vacuum operation without cavitation protection: 5 kPa · vacuum operation: 110 kPa · compressor operation, p1=101.3 kPa abs: 60 kPa · compressor operation: 300 kPa
Pumping speed 0.039 m³/h (dry air extraction, water at 15 °C)
Water vapor tolerance 3.9 l/min
Min. inlet pressure p1 min (without cavitation protection) (alt vacuum operation without cavitation protection) mfr 0.725 psi (vacuum operation without cavitation protection)
Max. discharge pressure p2 max (vacuum operation) (alt vacuum operation) mfr 16.0 psi (vacuum operation)
Max. discharge pressure (differential) p2 max (compressor operation) (alt compressor operation, p1=101.3 kPa abs) mfr 8.70 psi (compressor operation, p1=101.3 kPa abs)
Dimensions, Weight & Mechanical Design
Weight 9 kg
Weight (alt var) mfr 19.8 lb
Materials, Media & Process Compatibility
Oil capacity 0.200 l
Max. pre-pressure of operating liquid (alt var) mfr 300 kPa
Operating Conditions, Environment & Protection
Noise level 70 dB (50 Hz)
60 Hz: 70 dB
Operating temperature 110 °C
Ambient temperature limit 40 °C

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Process Limits
Do not exceed 5 kPa abs. inlet without cavitation protection

Operating below 5 kPa absolute during vacuum duty without cavitation protection risks cavitation damage to the liquid ring and impeller. If the process requires deeper vacuum, a cavitation-protection connection (G1/8 port) must be installed and the maximum achievable vacuum per the factory curve applies.

Operating Instructions, Chapter 3.3, Pg. 8
Process Limits
Cap discharge pressure at 110 kPa abs. in vacuum duty

During vacuum operation the maximum discharge pressure is 110 kPa abs. (16.0 psia). In compressor operation the maximum permissible internal pressure is 300 kPa abs. and the maximum differential pressure is 60 kPa at p1 = 101.3 kPa abs. Provide pressure-relief or interlock devices if the system can exceed these values.

Operating Instructions, Chapter 3.3, Pg. 8
Process Limits
Set operating-liquid flow to 0.65 l/min nominal

The nominal operating-liquid flow is 0.65 l/min (0.039 m³/h). In feed operation, set pre-pressure pA ≈ pB + 100 kPa above inlet pressure, or measure and adjust flow with a flow meter or graduated vessel. Insufficient flow degrades vacuum; excess flow raises power and liquid carry-over.

Operating Instructions, Chapter 7.3, Pg. 18
Process Limits
Limit entrained water via inlet to 3.9 l/min

The pump tolerates up to 3.9 l/min of water entrained through the inlet. If the process can carry more liquid, install an upstream separator to prevent flooding of the liquid ring and loss of vacuum performance.

Operating Instructions, Chapter 3.3, Pg. 8
Mounting
Keep 20 mm clearance from fan guard to adjacent surface

A minimum distance of 20 mm (0.787 in) between the fan guard and any adjacent surface is required for adequate cooling. Also ensure installation vibration velocity does not exceed 4.5 mm/s (0.177 in/s) to avoid bearing and seal damage.

Operating Instructions, Chapter 3.1, Pg. 7 and Chapter 6.1, Pg. 11-12
Mounting
Self-priming needs inlet pre-throttled to 80 kPa abs. at start

For self-priming operation, the inlet must be pre-throttled to at least 80 kPa abs. (11.6 psia) at switch-on. The liquid level at switch-on must equal shaft center, and during operation the reservoir level may not drop below approximately 1 m (3.28 ft) below shaft center. Design the feed pipe and reservoir accordingly.

Operating Instructions, Chapter 7.2, Pg. 17
Electrical
Use motor circuit breaker set to rating-plate current

The motor circuit breaker must be set to the nominal current specified on the drive motor rating plate. Supply tolerances of ±5% voltage and ±2% frequency are permissible without performance reduction; larger deviations require consultation with the Service Department.

Operating Instructions, Chapter 6.2, Pg. 13
Electrical
Maintain 5.5 mm minimum live-part clearance

Clearance between bare live parts, and between bare live parts and ground, must be at least 5.5 mm at nominal voltage UN ≤690 V. Observe terminal-board tightening torques: M4 1.0 Nm, M5 2.2 Nm, M3 modular terminal blocks 0.6 Nm.

Operating Instructions, Chapter 6.2, Pg. 13 and Chapter 3.1, Pg. 7
Piping
Observe tightening torques for G3/8 and G1/8 connections

Tightening torque for G3/8 intake and discharge connections must not exceed 16 Nm ±10% (11.8 ft·lb ±10%). G1/8 connections (operating liquid, cavitation protection, drain) require 4.5 Nm ±10%.

Operating Instructions, Chapter 3.1, Pg. 7

Selection & Integration Q&A

When should I choose the L-2BV 3151 instead of the L-2BV 7060 or the 2BV3151 sibling?

Choose the 3151 when you need a compact 9 kg pump with G3/8 ports and a 0.200 l liquid charge for vacuum duty to 5 kPa abs. (without cavitation protection) or compressor duty to 300 kPa abs. The 7060 offers higher inlet pressure (1.3 bar) for larger flows; the 2BV3151 shares the same ultimate pressure but is listed separately—verify port and liquid-volume differences before substituting.

What are the requirements for the motor supply and protection of this pump?

Use a motor circuit breaker set to the nominal current on the rating plate. Supply tolerance is ±5% voltage and ±2% frequency. Maintain ≥5.5 mm clearance between live parts and ground at UN ≤690 V. Terminal-board torques: M4 1.0 Nm, M5 2.2 Nm, M3 0.6 Nm.

What maintenance and accessories are required that are not included in the base delivery?

A start-up screen must be fitted in the inlet pipe for the first 100 operating hours. A check valve is required when connecting to a vacuum accumulator. For automatic operating-liquid feed, a solenoid valve linked to the motor is needed. Cavitation protection requires an external connection to the G1/8 port. Operating liquid (0.200 l max fill) and mating G3/8 fittings are not supplied.