Elmo Rietschle V-VCS 1100
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle V-VCS 1100

Elmo Rietschle V-VCS 1100 — Central Industrial & Medical Vacuum Systems with Motor power 36 kW, Noise level 81 dB, Ultimate pressure 1 mbar.

The V-VCS 1100 is an oil-flooded rotary vane vacuum pump in a once-through (dry-running) configuration, delivering 1100 m³/h at 50 Hz and 1320 m³/h at 60 Hz. It achieves 1.0 mbar ultimate vacuum with gas ballast, positioning it as the mid-large capacity model in the V-VCS series, above the V-VCS 400 and below the V-VCS 1300. It is intended for continuous central vacuum supply in industrial processes where high pumping speed and moderate ultimate vacuum are required.

Motor power
36 kW
Noise level
81 dB
Ultimate pressure
1 mbar
Weight
807 kg

Elmo Rietschle V-VCS Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBPumping speed, m³/hUltimate pressure, mbarWeight, kgCurrent, A
V-VCS 1100 Current 258126180742.9–74.5
V-VCS 100 ——————
V-VCS 200 ——————
V-VCS 40 1.163480.5392.34–4.07
V-VCS 400 9734000.535710.5–18.1

Full specifications

Core Performance & Functional Specifications
Motor power 22.0 kW (HQ IE3 50 Hz)
JQ IE3 60 Hz: 25.0 kW · HR IE3 50 Hz: 30.0 kW · JR IE3 60 Hz: 36.0 kW
Noise level 81 dB (50 Hz)
60 Hz: 84 dB
Pumping speed 26 l
50 Hz: 1100 m³/hour · 60 Hz: 1320 m³/hour
Ultimate pressure 1.0 mbar
Coarse vacuum: 20 mbar
Rotational speed 980 rpm (HQ IE3 50 Hz)
JQ IE3 60 Hz: 1185 rpm · HR IE3 50 Hz: 985 rpm · JR IE3 60 Hz: 1190 rpm
Nominal suction capacity mfr 1100 m3/h (50 Hz)
Nominal suction capacity mfr 1320 m3/h (60 Hz)
Ultimate vacuum (with gas ballast) mfr 1,0(20 ‡) mbar (abs.)
Ultimate vacuum (with gas ballast), coarse vacuum mfr 20 mbar (abs.)
Motor version mfr JR IE3
Motor speed mfr 985 min-1 (50 Hz)
Motor notes mfr UL(UR)
Diameter Øw* mfr 455 mm
Motor speed mfr 1190 min-1 (60 Hz)
Diameter Øw* mfr 386 mm (HQ IE3)
Diameter Øw* mfr 386 mm (JQ IE3)
Diameter Øw* mfr 455 mm (HR IE3)
Diameter Øw* mfr 455 mm (JR IE3)
øs mfr M16
t mfr M 50 x 1,5
R1 (exhaust) mfr Rp 3
Diameter (Øw*) mfr 386 mm (HQ IE3 / JQ IE3)
Diameter (Øw*) mfr 455 mm (HR IE3 / JR IE3)
Dimensions, Weight & Mechanical Design
Weight 807 kg
HQ IE3: 220 kg · JQ IE3: 223 kg · HR IE3: 410 kg · JR IE3: 403 kg
Length 1785 mm (HQ IE3 / JQ IE3)
HR IE3 / JR IE3: 1915 mm
max. Weight without motor mfr 807 kg
Motor weight mfr 403 kg
Total length a* mfr 1915 mm
Motor weight mfr 220 kg (HQ IE3)
Motor weight mfr 223 kg (JQ IE3)
Motor weight mfr 410 kg (HR IE3)
Total length a* mfr 1915 mm (HR IE3)
Motor weight mfr 403 kg (JR IE3)
Total length a* mfr 1915 mm (JR IE3)
Dimension a1 mfr 1135 mm
Dimension a2 mfr 1077 mm (fine vacuum)
Dimension a2 mfr 2034 mm (coarse vacuum)
Dimension b mfr 1122 mm
Dimension c mfr 805 mm (fine vacuum)
Dimension c mfr 920 mm (coarse vacuum)
Dimension d mfr 475 mm
Dimension e mfr 500 mm (fine vacuum)
Dimension e mfr 650 mm (coarse vacuum)
Dimension f mfr 500 mm
Dimension g mfr 685 mm (fine vacuum)
Dimension g mfr 795 mm (coarse vacuum)
Dimension h mfr 425 mm (fine vacuum)
Dimension h mfr 535 mm (coarse vacuum)
Dimension l mfr 375 mm
Dimension o mfr 480 mm
Dimension p mfr 699 mm (fine vacuum)
Dimension q mfr 441 mm
Dimension r mfr 605 mm (fine vacuum)
Dimension r mfr 490 mm (coarse vacuum)
Dimension u mfr 55 mm
Dimension a2 mfr 1077 mm
Dimension c mfr 805 mm
Dimension e mfr 500 mm
Dimension g mfr 685 mm
Dimension h mfr 425 mm
Dimension p mfr 699 mm
Dimension r mfr 605 mm
Dimension øs mfr M16
Dimension t mfr M 50 x 1,5
Electrical, Power & Drive Specifications
Current 42.0/24.3 A (HQ IE3 50 Hz)
JQ IE3 60 Hz: 50.4/29.0 A · HR IE3 50 Hz: 54.2/31.4 A · JR IE3 60 Hz: 74.5/42.9 A
Voltage 400/690 V (HQ IE3 50 Hz)
JQ IE3 60 Hz: 380/660 V · HR IE3 50 Hz: 400/690 V · JR IE3 60 Hz: 380/660 V
Motor current mfr 54,2 / 31,4 A (50 Hz)
Motor voltage mfr 380 / 660 V ± 10 % (60 Hz)
Motor current mfr 74,5 / 42,9 A (60 Hz)
Interfaces, Connections & Control
Inlet connection G 4
Outlet connection Rp 3
Materials, Media & Process Compatibility
Oil capacity mfr 26 l
Operating Conditions, Environment & Protection
Average noise level mfr 84 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and in different media

Installation, connection and operation

Integration & Operating Notes

Electrical
Motor supply must match 400/690 V ±10% at 50 Hz

The JR IE3 motor is wound for 400/690 V at 50 Hz or 380/660 V at 60 Hz with ±10% tolerance. Exceeding this range risks overheating and winding failure. Ensure the site voltage is within tolerance under load, and select contactors and overloads according to the rated current (54.2/31.4 A at 50 Hz).

Technical Data Sheet — VCS 1100 vacuum pump DE/EN, Electrical Data
Process Limits
Gas ballast required for condensable vapor duty

The ultimate vacuum of 1.0 mbar is specified with gas ballast. Without gas ballast, condensable vapors may emulsify the oil, reducing lubrication and ultimate pressure. For processes with high water vapor or solvent loads, ensure the gas ballast valve is open and sized for the vapor flow; otherwise, oil changes will be frequent.

Technical Data Sheet — VCS 1100 vacuum pump DE/EN, Performance Data
Cooling & Media
Water-cooled version available on request

The standard pump is air-cooled. For installations with high ambient temperature or where air cooling is inadequate, a water-cooled version can be specified. Cooling water connections and requirements are not detailed in the data sheet; consult the manufacturer for flow and temperature limits.

Technical Data Sheet — VCS 1100 vacuum pump DE/EN, Variants
Maintenance
Oil change interval depends on process cleanliness

The oil capacity is 26 l. Oil change intervals are not fixed in the data sheet; they depend on the process gas, dust load, and operating temperature. For clean, dry processes, intervals may be long; for dirty or condensable-laden processes, frequent changes are required. Monitor oil condition and change when contamination or emulsification is evident.

Technical Data Sheet — VCS 1100 vacuum pump DE/EN, Maintenance

Selection & Integration Q&A

When should I choose the V-VCS 1100 instead of the V-VCS 400 or V-VCS 1300?

Choose the 1100 when your required pumping speed is between 400 and 1300 m³/h at 50 Hz. The 1100 offers 1100 m³/h, filling the gap; the 400 is smaller and the 1300 larger. Consider the 1100 for central systems needing moderate capacity with 1 mbar ultimate vacuum.

What motor and electrical supply are required for the V-VCS 1100?

The specified JR IE3 motor is 30 kW at 50 Hz (400/690 V, 54.2/31.4 A) or 36 kW at 60 Hz (380/660 V, 74.5/42.9 A). The motor is not included as standard; it is a specified option. Ensure your supply matches the voltage and frequency, and provide motor protection rated for the current.

What maintenance items and accessories are not included with the base pump?

The base pump is supplied without motor and control gear. Oil (26 l capacity) is required for operation and must be specified separately; use manufacturer-recommended oil. Motor and coupling are optional. Suction filters, exhaust filters, and gas ballast valves are available as accessories; the gas ballast valve is required to achieve the 1.0 mbar ultimate vacuum and must be ordered if not included. Regular oil changes and filter replacements are required.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — VCS 1100 vacuum pump DE/EN)
Datasheet ·776,0 КБ ·4 pp.
View PDF