Elmo Rietschle V-VCS 400
Elmo Rietschle V-VCS 400 — Central Industrial & Medical Vacuum Systems with Motor power 9 kW, Noise level 73 dB, Pumping speed 400 m³/h.
The V-VCS 400 is a single-stage, oil-flooded rotary vane vacuum pump with a flanged three-phase motor, rated 400 m³/h at 50 Hz and 480 m³/h at 60 Hz. It achieves 0.5 mbar ultimate vacuum with gas ballast and is positioned between the V-VCS 200 and V-VCS 1100 in the series. It is intended for continuous fine-vacuum service in closed systems or process vacuum within 0.5–100 mbar (abs.).
Elmo Rietschle V-VCS Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Pumping speed, m³/h | Ultimate pressure, mbar | Weight, kg | Current, A |
|---|---|---|---|---|---|---|
| V-VCS 400 Current | 9 | 73 | 400 | 0.5 | 357 | 10.5–18.1 |
| V-VCS 100 | — | — | — | — | — | — |
| V-VCS 1100 | 25 | 81 | 26 | 1 | 807 | 42.9–74.5 |
| V-VCS 200 | — | — | — | — | — | — |
| V-VCS 40 | 1.1 | 63 | 48 | 0.5 | 39 | 2.34–4.07 |
Full specifications
| Motor power | 9.0 kW |
| Noise level | 73 dB (50 Hz) 60 Hz: 75 dB |
| Pumping speed | 400 m3/h (50 Hz) 60 Hz: 480 m3/h |
| Ultimate pressure | 0.5 (10) mbar |
| Rotational speed | 975 rpm (50 Hz) |
| Nennsaugvermögen / Nominal suction capacity mfr | 400 m3/h (50 Hz) |
| Nennsaugvermögen / Nominal suction capacity mfr | 480 m3/h (60 Hz) |
| Enddruck / Ultimate vacuum (with gas ballast) mfr | 0.5 mbar (with gas ballast) |
| Motor-Variante / Motor version mfr | HM IE3 (50 Hz) |
| Motor min-1 mfr | 975 min-1 (50 Hz) |
| Motor notes mfr | UL(UR) (HM IE3) |
| Øw* diameter mfr | 347 mm (HM IE3) |
| Motor-Variante / Motor version mfr | UN IE3 (50 Hz/60 Hz) |
| Motor min-1 mfr | 1170 min-1 (60 Hz) |
| Motor notes mfr | CSA, EAC, UL(UR) (UN IE3) |
| Øw* diameter mfr | 366 mm (UN IE3) |
| Nominal suction capacity mfr | 400 m3/h (50 Hz) |
| Nominal suction capacity mfr | 480 m3/h (60 Hz) |
| Ultimate vacuum (with gas ballast) mfr | 0,5 (10 ‡) mbar (abs.) |
| Weight | 357 kg HM IE3 9,0: 114 kg |
| Height | 347 mm (HM IE3 9,0) |
| Length | 1390 mm (HM IE3 9,0) |
| max. weight ohne Motor / max. Weight without motor mfr | 357 kg |
| Motor weight mfr | 114 kg (HM IE3) |
| Motor weight mfr | 170 kg (UN IE3) |
| a* total length mfr | 1450 mm (UN IE3) |
| a1 dimension mfr | 864 mm |
| a2 dimension mfr | 787 mm |
| b dimension mfr | 931 mm |
| c dimension mfr | 606 mm |
| d dimension mfr | 340 mm |
| e dimension mfr | 415 mm |
| f dimension mfr | 380 mm |
| g dimension mfr | 540 mm |
| h dimension mfr | 330 mm |
| l dimension mfr | 310 mm |
| o dimension mfr | 410 mm |
| p dimension mfr | 515 mm |
| q dimension mfr | 372 mm |
| r dimension mfr | 405 mm |
| øs dimension mfr | M12 |
| t dimension mfr | M 40 x 1.5 |
| u dimension mfr | 40 mm |
| max. Weight without motor mfr | 357 kg |
| Dimension a1 mfr | 864 mm |
| Dimension a2 mfr | 787 mm |
| Dimension b mfr | 931 mm |
| Dimension c mfr | 606 mm |
| Dimension d mfr | 340 mm |
| Dimension e mfr | 415 mm |
| Dimension f mfr | 380 mm |
| Dimension g mfr | 540 mm |
| Dimension h mfr | 330 mm |
| Dimension l mfr | 310 mm |
| Dimension o mfr | 410 mm |
| Dimension p mfr | 515 mm |
| Dimension q mfr | 372 mm |
| Dimension r mfr | 405 mm |
| Dimension øs mfr | M12 |
| Dimension t mfr | M 40 x 1,5 |
| Dimension u mfr | 40 mm |
| Current | 18.1 / 10.5 A (50 Hz) |
| Voltage | 400 / 690 V |
| Motor version HM IE3 mfr | 9,0 kW (50 Hz) |
| Motor voltage HM IE3 mfr | 400 / 690 V ± 10 % (50 Hz) |
| Motor speed HM IE3 mfr | 975 min-1 (50 Hz) |
| Motor current HM IE3 mfr | 18,1 / 10,5 A (50 Hz) |
| Motor notes HM IE3 mfr | UL(UR) |
| Motor weight HM IE3 mfr | 114 kg |
| Motor total length a* HM IE3 mfr | 1390 mm |
| Motor diameter Øw* HM IE3 mfr | 347 mm |
| Motor version UN IE3 mfr | 11,0 kW (50 Hz) |
| Motor voltage UN IE3 mfr | 330 | 380 / 660 V ± 10 % (50 Hz) |
| Motor speed UN IE3 mfr | 975 min-1 (50 Hz) |
| Motor current UN IE3 mfr | 24,4 | 21,2 / 12,2 A (50 Hz) |
| Motor version UN IE3 mfr | 13,0 kW (60 Hz) |
| Motor voltage UN IE3 mfr | 220 / 380 | 440 V ± 10 % (60 Hz) |
| Motor speed UN IE3 mfr | 1170 min-1 (60 Hz) |
| Motor current UN IE3 mfr | 42,8 / 24,8 | 21,4 A (60 Hz) |
| Motor notes UN IE3 mfr | CSA, EAC, UL(UR) |
| Motor weight UN IE3 mfr | 170 kg |
| Motor total length a* UN IE3 mfr | 1450 mm |
| Motor diameter Øw* UN IE3 mfr | 366 mm |
| Inlet connection | G 3 |
| Outlet connection | Rp 3 |
| Öleinfüllmenge / Oil capacity mfr | 12 l |
| Oil capacity mfr | 12 l |
| Average noise level mfr | 75 dB(A) (60 Hz) |
| Mittlerer Schalldruckpegel / Average noise level (EN ISO 3744) mfr | 73 dB(A) (50 Hz) |
| Mittlerer Schalldruckpegel / Average noise level (EN ISO 3744) mfr | 75 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage rotary vane principle: oil seals, lubricates and dissipates compression heat; suction side has a micro-fine or fine-mesh filter, outlet side an oil-mist separator returning oil to circulation.
- Integrated non-return valve prevents ventilation of the evacuated system after stop; standard gas ballast valve suppresses condensation of small water-vapour quantities.
- Flanged three-phase motor (HM IE3 at 50 Hz, UN IE3 at 60 Hz) with IP 55 protection and insulation class F; motor weight 114 kg (HM) or 170 kg (UN), total length 1390 mm or 1450 mm respectively.
- The V-VCS 400 is positioned between the V-VCS 200 and V-VCS 1100 in the series; it shares the fine-vacuum range 0.5–100 mbar (abs.) with the 500, 700 and 900, while the 1100 and 1300 require an additional oil separator housing for rough vacuum and have a narrower fine-vacuum range of 1–100 mbar.
Behavior under load and in different media
- Nominal suction capacity is 400 m³/h at 50 Hz and 480 m³/h at 60 Hz with free intake; ultimate vacuum with gas ballast is 0.5 mbar.
- Continuous operation is permitted within the fine-vacuum range 0.5–100 mbar (abs.). For rough-vacuum operation (10–500 mbar abs.), the next higher motor output should be selected; outside these ranges oil may leak through the outlet.
- When evacuating closed systems, the volume to be evacuated must not exceed 2% of the nominal pumping capacity per hour (i.e., 8 m³/h at 50 Hz).
- Average noise level is 73 dB(A) at 50 Hz and 75 dB(A) at 60 Hz (EN ISO 3744).
Installation, connection and operation
- The pump must be installed horizontally (max. inclination 1° in all directions), secured against tipping, on a plane floor able to carry its weight; at least 50 cm free space around the machine is required for maintenance access.
- Cooling air inlets and outlets must be at least 30 cm from adjacent walls; the installation room must be well ventilated because extracted air contains a small residue of oil aerosols.
- Pipes must be screwed in by hand only; flexible connections are recommended. The exhaust air opening must not be closed or restricted, no filter may be installed on the exhaust side, and counterpressure must not exceed +100 mbar.
- Oil filling (12 L capacity) is via both oil filling points up to the upper edge of the oil sight glass; oil viscosity must comply with ISO VG 100 (DIN ISO 3448).
- Electrical installation must be by a qualified electrician per EN 60204; the operating company must provide a main switch and motor protection switch. Direct-on-line starting is not permitted for this motor; use star-delta starting, soft starter or frequency converter.
- Permissible voltage deviation is ±5% and frequency deviation ±2% from nominal. The machine has no built-in Emergency Stop/Off; this must be implemented by the user.
Integration & Operating Notes
The exhaust line must be sized to keep counterpressure below +100 mbar. No filter may be installed on the exhaust side, and the exhaust air opening must not be closed or restricted. Higher counterpressure can overload the motor and damage the oil separator.
Selection & Integration Q&A
Choose the V-VCS 400 when your required pumping speed is around 400 m³/h at 50 Hz and ultimate vacuum of 0.5 mbar is sufficient. For higher capacities, select the V-VCS 500 (500 m³/h at 50 Hz) or larger. For rough-vacuum operation (10–500 mbar abs.), the next higher motor output should be selected; the V-VCS 1100 requires an additional oil separator for rough vacuum.
The exhaust line must be sized so that counterpressure does not exceed +100 mbar. Do not install any filter or shut-off valve on the exhaust side, and ensure the exhaust opening is not restricted. Use flexible connections and screw pipes in by hand only.
No, direct-on-line starting is not permitted for this motor. Use star-delta starting, a soft starter or a frequency converter. The user must provide a main switch and a motor protection switch; voltage deviation must be within ±5% and frequency within ±2%.
The base delivery does not include lubricating oil (ISO VG 100), spare filter cartridges, air-oil separator elements, or the additional oil separator housing (required only for V-VCS 1100–1300, not for the V-VCS 400). Flexible connections and a motor protection switch must be provided by the user. Refer to spare parts list E 233.