Elmo Rietschle VSI 301
Elmo Rietschle VSI 301 — Screw Vacuum Pumps with Motor power 9 kW, Pumping speed 360 m³/h, Ultimate pressure 0.08 mbar.
The S-VSI 301 is a dry-running twin-screw vacuum pump with continuous flow cooling (variant 01) or circulation cooling (31/61), achieving 300 m³/h at 50 Hz and 0.08 mbar ultimate pressure. It is distinguished within the VSI series by its 5.5/7.5/9.0 kW motor options and water-based cooling, serving as a high-capacity primary pump for humid or aggressive gas evacuation.
Elmo Rietschle VSI Series — Model Comparison & Selection
Full specifications
| Motor power | 7.5 kW (50 Hz | UL IE3) 60 Hz | UL IE3: 9.0 kW · 50 Hz | NI IE4: 5.5 kW · 50 Hz | NL IE4: 7.5 kW · 60 Hz | NL IE4: 9.0 kW |
| Pumping speed | 300 m³/h (50 Hz) 60 Hz: 360 m³/h |
| Ultimate pressure | 0.08 mbar |
| Rotational speed | 2930 rpm (50 Hz | UL IE3) 60 Hz | UL IE3: 3530 rpm · 50 Hz | NI IE4: 2935 rpm · 50 Hz | NL IE4: 2945 rpm · 60 Hz | NL IE4: 3540 rpm |
| Vacuum connection mfr | G 2 |
| Exhaust mfr | G 2 |
| Condensate drain mfr | G 1/2 |
| Height | 1246 mm (version 301 (01) | motor NI) version 301 (01) | motor NL: 1249 mm · version 301 (01) | motor UL: 1249 mm |
| Length | 838 mm (version 301 (01) | motor NI) version 301 (01) | motor NL: 839 mm · version 301 (01) | motor UL: 839 mm |
| Weight | 267 kg (version 301 (01)) version 301 (31): 307 kg |
| Width | 360 mm |
| Oil capacity | 1.4 l (H) H1 (H variant 0.8 / H1 variant 0.6): 0.8 l · H1: 0.6 l |
| Noise level | 73 dB (50 Hz | version 301 (01)) 60 Hz | version 301 (01): 75 dB · 50 Hz | version 301 (31): 76 dB · 60 Hz | version 301 (31): 78 dB |
| Operating temperature | 45 °C |
| Cooling type | water |
| Cooling method mfr | Continuous flow cooling (01) / circulation cooli |
| Cooling water inlet/outlet mfr | G 1/2 |
Description
Construction and Series Positioning
The S-VSI 301 is a screw vacuum pump with two dry-running rotors, driven via an elastomer coupling from an IE3/IE4 motor. The compression chamber is separated from the gearbox by special seals with a ventilated intermediate compartment. The VSI 301 delivers a pumping speed of 300 m³/h at 50 Hz (360 m³/h at 60 Hz) and an ultimate pressure of 0.08 mbar. Motor power options are 5.5 kW (50 Hz, NI IE4), 7.5 kW (50 Hz, UL IE3 or NL IE4), and 9.0 kW (60 Hz, UL IE3 or NL IE4). Cooling is water-based: continuous flow cooling (01), circulation cooling with water-air heat exchanger (31), or circulation cooling with water-water heat exchanger (61).
Behavior Under Load and Media
- Inlet pressure range for continuous vacuum: 0.08 to 1000 mbar (abs). Maximum suction capacity is 300 m³/h at 50 Hz and 360 m³/h at 60 Hz.
- Maximum permissible back pressure on the discharge side: +200 mbar for the 7.5 kW variant, +30 mbar for the 5.5 kW variant. The back-pressure limit for the 9.0 kW variant is not specified in the verified data; consult the manufacturer. Exceeding stated limits is inadmissible and may damage the pump.
- The 5.5 kW motor variant is restricted to continuous operation S1; frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits.
- The pump is particularly suitable for extremely humid gases and has high water-vapour tolerance. Optional sealing gas (max. 0.2 bar, 260 Nl/h) protects the gearbox when pumping aggressive media or during large pressure cycles.
Installation, Connection, and Control
- Mount horizontally with maximum inclination 8° in all directions. Provide at least 30 cm clearance from walls for cooling air and 50 cm free space for maintenance.
- Vacuum connection and exhaust: G 2; cooling water inlet/outlet: G 1/2; condensate drain: G 1/2; sealing gas connection: G 1/4.
- Cooling water supply pressure: 0.6–1.2 bar for circulation cooling (both water-air and water-water heat exchanger variants). For the water-water heat exchanger, the cooling water pressure at the plate heat exchanger must not exceed 10 bar, and inlet temperature must be 10–30 °C. Temperature control setpoint Tmax = 60 °C.
- Electrical: motor supply per data plate; circulation pump and fan require 230 V AC single-phase supplies. Solenoid valve for continuous flow cooling: 24 V DC, normally closed. For frequency converter variants, maintain IP 65 with suitable cable glands.
- The machine does not have its own emergency stop; integrate into the user's safety system.
Integration & Operating Notes
The pump must be installed horizontally with a maximum inclination of 8° in all directions to ensure proper lubrication and operation. During transport, the maximum inclination is 10°. Ensure the mounting surface is flat and level within these tolerances.
Operation outside this range requires consultation with the manufacturer. Ensure installation room ventilation and process gas cooling keep temperatures within this range. For installation above 1000 m above sea level, performance decreases; contact the manufacturer.
Selection & Integration Q&A
Choose VSI 301 for 300 m³/h at 50 Hz and 0.08 mbar ultimate, with water cooling. VSI 300 offers 320 m³/h but 0.1 mbar; VSI 100 is smaller at 110 m³/h. Select VSI 301 for lower ultimate pressure or water-based cooling needs; note that its pumping speed is lower than the VSI 300's.
Cooling water inlet temperature must be 10–30 °C, pressure at the plate heat exchanger ≤10 bar, and supply pressure at the pump 0.6–1.2 bar. Install filters with max. mesh size 0.1 mm at the heat exchanger inlets.
Base delivery excludes sealing gas unit, gas ballast valve, and frequency converter. Spare parts (e.g., filters, oil) must be ordered separately using the spare parts list E 834. Regular maintenance includes oil changes, air filter cleaning, and cooling system checks.