Nabertherm GF 75
Nabertherm ·Made in Germany · In Active Production

Nabertherm GF 75

Nabertherm GF 75 — Fusing.

The GF 75 is a fixed-table fusing furnace with a 620 × 620 × 310 mm chamber and 900 °C maximum temperature, powered by a 3.6 kW single-phase connection. It sits at the smaller end of the GF series, below the GF 240, and is intended for fusing processes that require a flat, stationary hearth rather than a tilting or rotating table.

Nabertherm GF Series — Model Comparison & Selection

Model Electrical connectionMax temperature, °CWeight, kg
GF 75 Current 1-phase900180
GF 240 3-phase950275

Full specifications

Core Performance & Functional Specifications
Electrical connection 1-phase
Electrical connection 1-phase
Nominal power 3.6 kW
Floor space mfr 0.38
Inner dimensions (W × D × H) mfr 620 × 620 × 310 mm
Outer dimensions (W × D × H) mfr 1070 × 950 mm
Dimensions, Weight & Mechanical Design
Weight 180 kg
Weight 180 kg
Operating Conditions, Environment & Protection
Max temperature 900 °C
Max temperature 900 °C

Description

Construction and series positioning

Thermal and electrical behavior

Control and operation

Integration & Operating Notes

Electrical
Single-phase 3.6 kW supply must be dedicated and correctly rated

The GF 75 draws 3.6 kW on a single-phase connection. The supply circuit, protective device, and wiring must be sized for the full nominal current with appropriate derating; sharing the circuit with other high-load equipment may cause voltage drop and control instability.

Factory Specification Sheet
Process Limits
Do not exceed 900 °C chamber temperature

The maximum temperature is 900 °C. Operating above this limit risks damage to the heating elements and insulation. The controller should be configured with an appropriate setpoint limit to prevent accidental overshoot.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the GF 75 instead of the larger GF 240 in the same series?

Choose the GF 75 when the workload fits within its 620 × 620 × 310 mm chamber and the 900 °C maximum is sufficient. The GF 240 offers a larger chamber for bigger batches; select it when the GF 75 chamber size or 3.6 kW power is limiting.

What electrical supply and protective devices are required for the GF 75?

The GF 75 requires a single-phase supply capable of delivering 3.6 kW. A dedicated circuit with a protective device rated for the nominal current and wiring sized for the load is necessary; consult local electrical codes for disconnection and grounding requirements.

What maintenance and accessories are needed for the GF 75, and what is not included?

No furnace-specific maintenance schedule is provided in the available documents. Controller options, the MyNabertherm app, and AMS2750F instrumentation are documented separately and are not part of the base delivery. Regular inspection of heating elements and thermocouples is recommended per standard practice.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF