No photo available yet
Nabertherm SAL 250/85
Nabertherm SAL 250/85 — Forced Convection Furnaces.
The SAL 250/85 is a forced-convection pit-type furnace with a 250-litre chamber (600 × 600 × 750 mm) and a maximum working temperature of 850 °C. It is the larger of the two SAL 85-series models, distinguished from the SAL 120/85 by its 250-litre volume and 250 kg maximum charge weight. It is intended for uniform heat treatment of dense loads in a floor-level configuration.
Nabertherm SAL Series — Model Comparison & Selection
| Model | Chamber volume, L | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|---|
| SAL 250/85 Current | 250 | 600 | 3-phase | 850 |
| SAL 120/85 | 120 | 400 | 3-phase | 850 |
Full specifications
| Chamber volume | 250 l |
| Chamber volume | 250 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 20 |
| Inner dimensions (W × D × H) mfr | 600 × 600 × 750 mm |
| Outer dimensions (W × D × H) mfr | 1500 × 1300 × 1600 mm |
| Weight | 600 kg |
| Weight | 600 kg |
| Max. charging weight mfr | 250 |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- The SAL 250/85 is a pit-type furnace: the chamber is loaded from above, with inner dimensions of 600 mm width × 600 mm depth × 750 mm height and outer dimensions of 1500 × 1300 × 1600 mm.
- Within the SAL 85 series, the 250/85 is the larger modification; the sibling SAL 120/85 offers a 120-litre chamber. Selection between them is driven by charge volume and weight rather than by temperature, since both share the 850 °C maximum temperature.
- The furnace is electrically heated and connected to a 3-phase supply; the unit weight is 600 kg.
Working range and load behaviour
- The maximum temperature is 850 °C. The maximum charging weight is 250 kg, which must be respected independently of the chamber volume.
- Forced convection is the defining feature of the category; the available documents do not provide curve points or atmosphere data for this model, so no cooling-rate or uniformity figures are asserted here.
Installation and control
- The pit-type format requires floor-level installation with access from above; the 1600 mm outer height and 600 kg weight must be accounted for in the foundation and handling plan.
- Controller and process-data functions are covered by the Nabertherm controller series 500 and MyNabertherm app documentation; the specific controller fitted to this unit is not stated in the verified facts.
Integration & Operating Notes
The maximum charging weight is 250 kg. A load that fits within the 600 × 600 × 750 mm chamber can still exceed this limit if it is dense; the charge must be weighed or calculated, not judged by chamber fill alone.
The maximum temperature of 850 °C applies to the furnace; processes requiring higher temperatures must use a different furnace category. Exceeding it risks damage to the heating elements and chamber insulation.
Process control functions, data storage and recorder options are described in the Nabertherm controller documentation (series 500 and MyNabertherm app). The controller configuration for this specific unit is not fixed in the verified facts and must be confirmed at order.
Selection & Integration Q&A
Choose the SAL 250/85 when the charge requires the 250-litre chamber (600 × 600 × 750 mm) or approaches the 250 kg charging weight. The SAL 120/85 has a 120-litre chamber; both share the 850 °C maximum temperature, so the decision is volume and load weight, not temperature.
The furnace is a 3-phase unit. The verified facts do not state the connected load in kW or the full-load current, so the feeder, breaker and cable sizing must be based on the nameplate data supplied with the unit, not on generic assumptions.
The verified facts list only the furnace itself; controller type, recorder options and process-data software are described in separate Nabertherm controller documentation and are not confirmed as part of the base delivery. Confirm controller, thermocouples and any recorder as order options.