Shimadzu I Series
Shimadzu I Series — Chromatographs.
The Shimadzu LC-2070 series comprises integrated HPLC systems with a four-solvent low-pressure gradient pump, total-volume injection autosampler, and UV or PDA detection. This model (LC-2070) is the base UV configuration without sample cooler, distinguished from the LC-2070C (cooled) and LC-2070C 3D (PDA) siblings. It serves as a compact, high-pressure (up to 50 MPa) analytical platform for routine gradient separations.
Direct drop-in replacements
Full specifications
| Detector types | UV (LC-2070) |
| Maximum pressure (3.0001 to 5 mL/min) mfr | 44 MPa (3.0001 to 5 mL/min) |
| Detector (LC-2070C) mfr | UV (LC-2070C) |
| Detector (LC-2070C 3D) mfr | PDA (LC-2070C 3D) |
| Detector (LC-2080C) mfr | UV (LC-2080C) |
| Detector (LC-2080C 3D) mfr | PDA (LC-2080C 3D) |
| Column capacity (column oven) mfr | up to six 100 mm columns (column oven) |
| Maximum pressure (LC-2070C / LC-2080C, 3.0001 to 5 mL/min) mfr | 44 MPa (LC-2070C / LC-2080C, 3.0001 to 5 mL/min) |
| System delay volume (LC-2070C) mfr | 650 μL (LC-2070C) |
| System delay volume (LC-2080C) mfr | 460 μL (LC-2080C) |
| System delay volume option (LC-2070C) mfr | 460, 1100 μL (LC-2070C) |
| System delay volume option (LC-2080C) mfr | 650, 1100 μL (LC-2080C) |
| Flow cell volume (Conventional cell, 10 mm, TC) mfr | 12 μL (Conventional cell, 10 mm, TC) |
| Flow cell volume (High-Speed cell, 10 mm, TC) mfr | 8 μL (High-Speed cell, 10 mm, TC) |
| Flow cell pressure rating (Flow cell) mfr | 12 MPa (Flow cell) |
| Detector wavelength range (UV detector) mfr | 200 to 650 nm (UV detector) |
| Detector wavelength range (PDA detector) mfr | 200 to 750 nm (PDA detector) |
| Detector dimensions (W × D × H) (UV detector) mfr | 260 × 420 × 210 mm (UV detector) |
| Injection cycle time (Autosampler) mfr | 14 s (Autosampler) |
| Maximum sample capacity (Autosampler, using 384-well MTPs) mfr | 1536 samples (Autosampler, using 384-well MTPs) |
| Carryover (Autosampler) mfr | < 0.0004 % (Autosampler) |
| Minimum injection volume (Autosampler, reproducible/linear) mfr | 1 μL (Autosampler, reproducible/linear) |
| Weight | 58 kg (LC-2070) |
| Weight (LC-2070C / LC-2070C 3D) mfr | 63 kg (LC-2070C / LC-2070C 3D) |
| Weight (LC-2080C / LC-2080C 3D) mfr | 63 kg (LC-2080C / LC-2080C 3D) |
| Detector weight (UV detector) mfr | 16 kg (UV detector) |
| Detector weight (PDA detector) mfr | 18 kg (PDA detector) |
Description
Construction and Series Positioning
The LC-2070 is a fully integrated HPLC system combining a quaternary low-pressure gradient pump, autosampler, and UV detector in a single 58 kg chassis. Within the series, it is the entry UV variant: the LC-2070C adds a sample cooler (4–45 °C), and the LC-2070C 3D replaces the UV detector with a photodiode array (PDA). All share the same pump, autosampler, and pressure specifications. The pump features a five-line degassing unit (four mobile phases + one rinse solution, 400 µL) and supports gradient formation from 0 to 100% in 0.1% steps. ### Hydraulic and Injection Behavior
Maximum operating pressure is flow-dependent: 50 MPa up to 3 mL/min, 44 MPa from 3.0001 to 5 mL/min, and 22 MPa from 5.0001 to 10 mL/min. The system delay volume is 650 µL standard, with 460 µL and 1100 µL options. The autosampler uses total-volume injection, with injection volumes from 0.1 to 100 µL standard (options up to 2000 µL). Injection accuracy is ±1% at 50 µL (N=10), and reproducibility ranges from RSD <0.20% for 5–2000 µL down to RSD <1.0% for 0.5–0.9 µL. The available pH range is 1 to 13, compatible with standard reversed-phase methods. The system is designed for benchtop use and requires connection to laboratory power and data systems per Shimadzu's standard instructions. The absence of a sample cooler means samples are processed at ambient temperature, which may affect thermally labile analytes compared to the LC-2070C.
Integration & Operating Notes
Exceeding 50 MPa at flows up to 3 mL/min, 44 MPa between 3.0001 and 5 mL/min, or 22 MPa above 5 mL/min risks column or system damage. Method development must account for the flow-dependent pressure ceiling, especially when scaling up flow rate or using small-particle columns.
Mobile phases outside pH 1–13 can degrade the pump, injector, and detector flow cell. Buffers and additives must be chosen accordingly, and post-run flushing is recommended to remove aggressive salts.
The degassing unit includes a dedicated rinse solution line (400 µL volume) to flush the autosampler. This reservoir must be kept filled with appropriate solvent (e.g., water or methanol) to prevent precipitate buildup and injection carryover; check level before each batch.
Selection & Integration Q&A
Choose the LC-2070 for ambient-temperature UV detection when sample cooling is unnecessary and PDA spectral data is not required. The LC-2070C adds a 4–45 °C sample cooler for thermally labile analytes; the LC-2070C 3D provides PDA detection for peak purity and multi-wavelength analysis.
The base LC-2070 includes the pump, autosampler, UV detector, and standard 100 µL injection kit. Optional injection volumes (up to 2000 µL), delay volume kits (460 µL or 1100 µL), and the sample cooler are not included. Routine maintenance parts such as column, filters, and tubing are user-supplied.