Waters RADIAN ASAP Single Quadrupole Direct Mass Detector
Waters ·Made in USA · In Active Production

Waters RADIAN ASAP Single Quadrupole Direct Mass Detector

Waters RADIAN ASAP Single Quadrupole Direct Mass Detector — Mass spectrometers.

The RADIAN ASAP is a single quadrupole mass detector configured with an Atmospheric Solids Analysis Probe (ASAP) for direct analysis of solids and liquids without chromatographic separation. It delivers nominal-mass confirmation in approximately 30 seconds per sample, distinguishing it from LC-MS or GC-MS variants that require separation time. It is used for rapid screening and identity checks in laboratories where speed and simplicity outweigh high-resolution accuracy.

Direct drop-in replacements

Shimadzu
Axima Assurance
0%
match
⚖️ Compare
Shimadzu
Axima Confidence
0%
match
⚖️ Compare
0%
match
⚖️ Compare
Shimadzu
GC-MS Qp2020 NX
0%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Type single quadrupole
Ion source Atmospheric Solids Analysis Probe (ASAP)
analysis time mfr approximately 30 seconds per sample

Description

Construction and positioning

Integration & Operating Notes

Process Limits
ASAP probe requires sample deposition on the probe tip

Samples must be applied directly to the ASAP probe capillary and dried before insertion; liquid samples may need a solvent that evaporates completely to avoid source contamination. The probe operates at atmospheric pressure and is inserted into the source only after the sample is ready.

Waters RADIAN ASAP System Overview
Maintenance
Replace ASAP probe capillary after high-concentration samples

The disposable capillary at the tip of the ASAP probe is a consumable; it should be replaced when carryover is observed or after analyzing samples with high analyte concentration. Keep spare capillaries and probe assemblies on hand to avoid downtime.

Waters ASAP Probe User Guide

Selection & Integration Q&A

When should I choose the RADIAN ASAP instead of an LC-MS or GC-MS single quadrupole?

Choose the ASAP when you need rapid, direct analysis of solids or liquids without separation, such as raw material identification or reaction monitoring. For complex mixtures requiring chromatographic separation, an LC-MS or GC-MS configuration is necessary.

What maintenance is required for the ASAP probe?

The probe capillary should be replaced when carryover is detected or after high-concentration samples. The probe body can be cleaned with appropriate solvents. Regular replacement of the capillary ensures reproducible results.

What accessories are needed but not included with the base instrument?

The MassLynx software, ASAP probe capillaries, and a nitrogen generator or gas cylinder are typically not included and must be ordered separately. A computer meeting the software specifications is also required.