Waters Xevo CDMS — Mass spectrometers.

The Xevo CDMS is a benchtop charge detection mass spectrometer (CDMS) with single-ion detection and ELIT technology, enabling direct mass measurement from approximately 10 kDa to 150 MDa and beyond. It is distinguished within the series by its nanoESI source and optional AutoLoader for unattended sample introduction. It is intended for high-resolution analysis of complex mixtures such as viral particles, protein assemblies, and exosomes.

Direct drop-in replacements

Shimadzu
Axima Assurance
0%
match
⚖️ Compare
Shimadzu
Axima Confidence
0%
match
⚖️ Compare
0%
match
⚖️ Compare
Shimadzu
GC-MS Qp2020 NX
0%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Resolution High-resolution MS analysis of complex mixtures
Ion source nanoESI source
Technology mfr Charge detection mass spectrometry with single-i
Detection mfr Direct mass measurement powered by ELIT technolo
Sample Types mfr viral particles, protein assemblies, and exosome
Automation mfr Optional nanoESI AutoLoader for reproducible, un
Recommended Use mfr For direct analysis of biomolecules in the megad
Dimensions, Weight & Mechanical Design
Mass range ~ 10kDa to 150 Mda and beyond
Instrument Footprint mfr Modern benchtop design with revolutionary nanoES
Interfaces, Connections & Control
User Interface mfr Intuitive software with guided workflows

Description

Integration & Operating Notes

Maintenance
AutoLoader is an option, not part of base delivery

Unattended, reproducible sample introduction requires the optional nanoESI AutoLoader; without it, samples must be introduced manually. Plan consumables and scheduling around whichever introduction mode is configured.

Factory Specification Sheet
Control & I/O
Operation via guided-workflow software interface

The instrument is controlled through an intuitive software interface with guided workflows; no external controller, I/O signal list, or interlock logic is documented in the supplied facts, so integration with lab automation must be confirmed with the vendor.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Xevo CDMS rather than another mass spectrometer for large assemblies?

Choose it for direct mass measurement of viral particles, protein assemblies, and exosomes from ~10 kDa to 150 MDa and beyond, where single-ion charge detection avoids calibration standards. For small molecules or routine LC-MS, a conventional platform is more appropriate.

What sample-introduction setup is required to run the Xevo CDMS unattended?

The base instrument includes a nanoESI source for manual introduction; reproducible, unattended operation requires the optional nanoESI AutoLoader, which must be specified at order time since it is not part of base delivery.

What installation and duty-cycle limits apply to the Xevo CDMS?

It is a modern benchtop instrument, but the supplied documentation contains no electrical, environmental, or duty-cycle specifications; confirm power, bench space, and operating conditions with Waters before installation.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation