Waters Xevo TQ-XS Triple Quadrupole Mass Spectrometer
Waters ·Made in USA · In Active Production

Waters Xevo TQ-XS Triple Quadrupole Mass Spectrometer

Waters Xevo TQ-XS Triple Quadrupole Mass Spectrometer — Mass spectrometers.

The Xevo TQ-XS is a triple quadrupole mass spectrometer with two high-resolution quadrupole analyzers (MS1/MS2), a T-Wave collision cell, and a StepWave XS ion transfer optic. It covers a mass range of 2 to 2048 m/z and achieves MRM speeds of 500 transitions per second, distinguishing it within the series by its standard tool-free ESI/APCI/ESCi multi-mode source. It is used for targeted quantitation in pharmaceutical, clinical, and environmental laboratories.

Direct drop-in replacements

Shimadzu
Maldimini 1
76%
match
⚖️ Compare
Shimadzu
Nexera Mikros
76%
match
⚖️ Compare
Shimadzu
MALDI 8020
4%
match
⚖️ Compare
Shimadzu
Axima Assurance
0%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Detector types Low-noise, off-axis, long-life photomultiplier XDR detector
Ion source Multi-mode source – tool free ESI/APCI/ESCi (standard); UniSpray ion source (optional); Tool-free APCI probe (optional); nanoFlow ESI source (optional); ASAP (optional); APGC ion source (optional); ionKey source (optional)
Collision cell mfr T-Wave enabled; Software programmable gas contro
Vacuum system mfr Three air-cooled turbomolecular vacuum pumps; On
Regulatory approvals/marks mfr CE, CB, NRTL (CAN/US), RCM
MRM speed mfr 500 MRM/sec
Ion source transfer optics mfr StepWave XS
Dimensions, Weight & Mechanical Design
Mass range 2 to 2048 m/z
Height 70.7 cm
Width 61.0 cm
Depth mfr 99.5 cm (39.0 in.)
Mass analyzer mfr Two high-resolution, high-stability quadrupole a

Description

Construction and architecture

Integration & Operating Notes

Mounting
Bench space and ventilation required

The instrument measures 70.7 cm high, 61.0 cm wide, and 99.5 cm deep, and uses air-cooled turbomolecular pumps; ensure the bench can support the weight and that clearance allows adequate airflow for cooling.

Factory Specification Sheet
Electrical
Verify local power compatibility

The Xevo TQ-XS carries CE, CB, NRTL (CAN/US), and RCM marks, indicating compliance with regional electrical safety standards; confirm that the available supply matches the instrument's voltage and current requirements before installation.

Factory Specification Sheet
Process Limits
Mass range limited to 2–2048 m/z

Ions outside this range are not transmitted or detected; method development must ensure all target analytes and their fragments fall within 2 to 2048 m/z to avoid invalid results.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Xevo TQ-XS over other triple quadrupole models in the series?

Choose the Xevo TQ-XS when you need high MRM speed (500 MRM/sec) and a mass range up to 2048 m/z with the standard tool-free ESI/APCI/ESCi source. For specialized ionization like nanoFlow or APGC, consider models with those options pre-configured.

What are the requirements for connecting the Xevo TQ-XS to my existing LC system?

The standard multi-mode source accepts tool-free ESI/APCI/ESCi probes, so the LC outlet connects directly to the source. Ensure the LC flow rate and mobile phase are compatible with the chosen ionization mode; for other sources like UniSpray or APGC, additional hardware is required.

What maintenance items and accessories are not included with the base Xevo TQ-XS delivery?

The base delivery includes the standard multi-mode source (ESI/APCI/ESCi). Optional sources (UniSpray, nanoFlow ESI, ASAP, APGC, ionKey) and the tool-free APCI probe are not included. Consumables such as LC columns, solvents, and calibration standards are also not part of the base package.

Dimensional Drawings & Technical Documentation

Technical documentation