Shimadzu MALDI 8020
Shimadzu ·Made in Japan · In Active Production

Shimadzu MALDI 8020

Shimadzu MALDI 8020 — Mass spectrometers.

The Shimadzu MALDI 8020 is a benchtop linear MALDI-TOF mass spectrometer configured for positive-ion linear mode, using a 355 nm solid-state laser with variable pulse rates of 50, 100, or 200 Hz. It covers a mass range of m/z 1 to 500,000 with resolution greater than 5,000 FWHM and sensitivity better than 250 amol. This modification is intended for routine intact-mass analysis of large biomolecules in a compact laboratory footprint.

Direct drop-in replacements

100%
match
⚖️ Compare
Waters
Xevo MRT P10
58%
match
⚖️ Compare
33%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Type benchtop, linear MALDI-TOF mass spectrometer (MALDI-8020)
Ion source linear mode (positive ion) MALDI (MALDI-8020)
Wavelength 355 nm (MALDI-8020)
Resolution (4.2 kDa peptide, average) mfr >5000 FWHM (4.2 kDa peptide, average)
Flow rate (LCMS single quadrupole, 70-mer DNA analysis) mfr 0.3 mL/min (LCMS single quadrupole, 70-mer DNA analysis)
Detection wavelength range (PDA detection, 70-mer DNA analysis) mfr 200-400 nm (PDA detection, 70-mer DNA analysis)
Ionization mode (LCMS single quadrupole, 70-mer DNA analysis) mfr ESI/APCI (DUIS), Negative mode (LCMS single quadrupole, 70-mer DNA analysis)
Flow rate (LCMS single quadrupole, FLP impurity analysis) mfr 0.3 mL/min (LCMS single quadrupole, FLP impurity analysis)
UV detection wavelength range (LCMS single quadrupole, FLP impurity analysis) mfr 190-400 nm (LCMS single quadrupole, FLP impurity analysis)
Injection volume (LCMS single quadrupole, FLP impurity analysis) mfr 6 μL (LCMS single quadrupole, FLP impurity analysis)
Scan mode (LCMS single quadrupole, FLP impurity analysis) mfr Scan (m/z 550-2000) (LCMS single quadrupole, FLP impurity analysis)
Nebulizing gas flow (LCMS single quadrupole, FLP impurity analysis) mfr 3.0 L/min (LCMS single quadrupole, FLP impurity analysis)
Drying gas flow (LCMS single quadrupole, oligonucleotide impurity analysis) mfr 5.0 L/min (LCMS single quadrupole, oligonucleotide impurity analysis)
Co-injection volumes (Nexera XS inert, co-injection pretreatment) mfr 1, 3, 5 μL (Nexera XS inert, co-injection pretreatment)
Dimensions, Weight & Mechanical Design
Height 1055 mm (MALDI-8020)
Weight 92 kg (MALDI-8020)
Width 600 mm (MALDI-8020)
Depth mfr 745 mm (MALDI-8020)
Electrical, Power & Drive Specifications
Mobile phase A composition (LCMS single quadrupole, 70-mer DNA analysis) mfr 95.4 mM HFIP, 7.1 mM TEA in water (LCMS single quadrupole, 70-mer DNA analysis)
Mobile phase A composition (Nexera XS inert, oligonucleotide impurity analysis) mfr 100 mmol/L HFIP, 10 mmol/L TEA in water (Nexera XS inert, oligonucleotide impurity analysis)
Flow rate (Reversed-phase ion-pair chromatography optimization) mfr 0.35 mL/min (Reversed-phase ion-pair chromatography optimization)
Interfaces, Connections & Control
Interface voltage (LCMS single quadrupole, 70-mer DNA analysis) mfr -2.0 kV (LCMS single quadrupole, 70-mer DNA analysis)
Operating Conditions, Environment & Protection
Noise (quiet operation) mfr <55 dB (quiet operation)

Description

Construction and positioning

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
mo432
Datasheet ·1,4 МБ ·4 pp.
View PDF
PDF
c10g-e097
Datasheet ·7,0 МБ ·48 pp.
View PDF