| Temperature range |
+5 °C above ambient temperature to 300 °C
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Temperature uniformity at 150°C |
3.8 ± K
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Temperature fluctuation at 150°C |
0.7 ± K
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Heating up time to 150°C |
29 min
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Recovery time after door was opened for 30 s at 150°C |
6 min
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Air change rate at 150°C |
18 x/h
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Rated voltage |
400 V
p.2 ↗ |
FED400-400V |
| Rated voltage |
208 V
p.2 ↗ |
FED400UL-208V |
| Power frequency |
50/60 Hz
p.2 ↗ |
FED400-400V |
| Power frequency |
60 Hz
p.2 ↗ |
FED400UL-208V |
| Nominal power |
3,4 kW
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Unit fuse |
16,0 A
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Phase (nominal voltage) |
3~/N/PE
p.2 ↗ |
FED400-400V |
| Phase (nominal voltage) |
3~
p.2 ↗ |
FED400UL-208V |
| Interior volume |
400 L
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Net weight of the unit (empty) |
145 kg
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Load per rack |
35 kg
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Permitted load |
90 kg
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Wall clearance back |
160 mm
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Wall clearance sidewise |
100 mm
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Width net |
1,235 mm
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Height net |
1,025 mm
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Depth net |
765 mm
p.2 ↗ |
FED400-400V / FED400UL-208V |
| Interior width |
1,000 mm
p.3 ↗ |
FED400-400V / FED400UL-208V |
| Interior height |
800 mm
p.3 ↗ |
FED400-400V / FED400UL-208V |