Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — C-KLR 80 IE3 vacuum pump DE/EN)

Technical Reference Summary

Covered Models & Document Scope

C-KLR 80 and C-KLR 140 dry, contact-free claw pressure-vacuum pumps with IE3 motors; 50 Hz and 60 Hz operation; other voltages available on request; motor starter for 60 Hz on request.

Technical Data

Parameter Value Condition
Rated voltage 230 / 400 V ± 10 % p.1 ↗ C-KLR 80, 50 Hz
Rated voltage 400 / 690 V ± 10 % p.1 ↗ C-KLR 140, 50 Hz
Motor rating 4,0 kW p.1 ↗ C-KLR 80, 50 Hz
Motor rating 5,5 kW p.1 ↗ C-KLR 140, 50 Hz
Motor rating 6,5 kW p.2 ↗ C-KLR 80 / 140, 60 Hz
Current consumption 13,0 / 7,5 A p.1 ↗ C-KLR 80, 50 Hz
Current consumption 10,1 / 5,86 A p.1 ↗ C-KLR 140, 50 Hz
Motor efficiency 89,5 % p.1 ↗ C-KLR 80, 50 Hz
Motor efficiency 90,0 % p.1 ↗ C-KLR 140, 50 Hz
Speed 2900 rpm p.1 ↗ 50 Hz
Average noise level 79 dB(A) p.1 ↗ C-KLR 80, 50 Hz, EN ISO 3744
Average noise level 82 dB(A) p.1 ↗ C-KLR 140, 50 Hz, EN ISO 3744
Weight 136 kg p.1 ↗ C-KLR 80
Weight 170 kg p.1 ↗ C-KLR 140
Oil capacity 0,55 l p.1 ↗ C-KLR 80
Oil capacity 0,60 l p.1 ↗ C-KLR 140
Capacity 94 m³/h p.2 ↗ C-KLR 80, 50 Hz, vacuum 0 bar
Capacity 88 m³/h p.2 ↗ C-KLR 140, 50 Hz, vacuum 0 bar
Capacity 117,8 m³/h p.2 ↗ C-KLR 80, 60 Hz, vacuum 0 bar
Capacity 113,1 m³/h p.2 ↗ C-KLR 140, 60 Hz, vacuum 0 bar
Vacuum -0,6 bar p.1 ↗ C-KLR 80 / 140
Overpressure +1,0 bar p.1 ↗ C-KLR 80 / 140
Protection rating IP 55 p.1 ↗ flange motors
Insulation class F p.1 ↗ flange motors
Inlet connection G 11/4 p.3 ↗ C-KLR 80

Operating Limits

  • Max vacuum: -0,6 bar p.1 ↗
  • Max overpressure: +1,0 bar p.1 ↗
  • Protection rating: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Capacity tolerance: ±10 % p.1 ↗
  • Noise level tolerance: ±3 dB(A) p.1 ↗

Type Code Decoder

Position Token Meaning
1-5 p.1 ↗ C-KLR Series: dry claw pressure-vacuum pump
6-8 p.1 ↗ 80 / 140 Size / nominal capacity class (m³/h)

Related models