Agilent Technologies 1260 Infinity III Prime LC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity III Prime LC System

Agilent Technologies 1260 Infinity III Prime LC System — Liquid chromatography with Flow rate 9×10⁻⁴ liter/minute, Motor power 0.11 kW.

The 1260 Infinity II GPC/SEC System is a high-performance gel permeation/size-exclusion chromatography system built around a 1260 Infinity II LC platform with a deuterium lamp detector and up to 120 Hz data acquisition. It is positioned between the compact 1220 Infinity II LC and the higher-pressure 1290 Infinity III LC, and is intended for polymer molecular-weight distribution analysis in organic or aqueous GPC/SEC modes.

Flow rate
9×10⁻⁴ liter/minute
Motor power
0.11 kW

Agilent Technologies Analytical HPLC Systems Series — Model Comparison & Selection

Model Flow rate, liter/minuteSample volume, milliliterColumn temperature, °CData rate, HzOperating altitude, mWeight, kg
1260 Infinity III Prime LC System Current 9×10⁻⁴0.0024040300011.5
1220 Infinity II LC System —15080200030
1260 Infinity III LC System 0.60.00540120——

Full specifications

Core Performance & Functional Specifications
Flow rate 0.9 mL/min
Motor power 110 VA
Column temperature 40 °C
Data Rate 40 Hz
Energy Consumption 1282 kJ
Light source Deuterium lamp
Maximum Data Acquisition Rate 120 Hz
Operating Hours 967 Hours
Sample volume 2 µL
Water gradient mfr 2.0
Detection type mfr 1024 array
Number of signals mfr 8
UV Detector mfr 240 rate
UV detection wavelength mfr 240 nm
Waters pressure rating mfr 689 bar
Dimensions, Weight & Mechanical Design
Weight 11.5 kg
Dimensions (height × width × depth) mfr 140 mm
Electrical, Power & Drive Specifications
Line voltage mfr 100...240
Line frequency mfr 50 Hz
Mobile Phase mfr A) Water B) Acetonitrile Acetonitrile
Operating Conditions, Environment & Protection
Operating Altitude 3000 m
Humidity mfr 95 % r.h.

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Electrical
Verify 50 Hz line frequency before commissioning

The system is rated for 100–240 V at 50 Hz only; operation on a 60 Hz supply is not covered by the verified specifications and may affect pump and detector timing. Confirm site frequency and provide a stable, grounded supply sized for the 110 VA motor power.

Factory Specification Sheet
Environment
Keep ambient within 4–55 °C and below 95% RH

The system is rated for 4–55 °C operating ambient and up to 95% relative humidity; exceeding these limits can cause condensation in the detector optics or drift in retention times. If the lab exceeds 3000 m altitude, detector performance may degrade.

Factory Specification Sheet
Process Limits
Aqueous and organic GPC/SEC modes supported

The water gradient rating of 95 indicates the system can run aqueous SEC eluents; for organic GPC, ensure solvent compatibility with the deuterium lamp detector flow cell and the 1024-element array. No pressure limit is stated in the verified facts, so consult the pump manual for maximum operating pressure.

Factory Specification Sheet
Maintenance
Track deuterium lamp hours against 967-hour rating

The deuterium lamp has a rated operating life of 967 hours; log lamp-on time and schedule replacement before intensity drop affects baseline noise. The detector's 8 signal channels and 120 Hz acquisition rate should be verified after lamp replacement using a reference standard.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 1260 Infinity II GPC/SEC System instead of the 1220 Infinity II LC or the 1260 Amino Acid Analysis System?

Choose this system for polymer molecular-weight distribution by GPC/SEC in organic or aqueous mode, where the 120 Hz acquisition and 8 signal channels resolve narrow peaks. The 1220 Infinity II LC is a compact general HPLC with lower acquisition rates; the 1260 Amino Acid Analysis System is dedicated to amino acid chemistry and not suitable for GPC/SEC.

What maintenance is required for the detector and how often?

The deuterium lamp is rated for 967 operating hours; track lamp-on time and replace before intensity falls below acceptable baseline noise. After replacement, verify the 8 signal channels and 120 Hz data acquisition rate with a reference standard. No other maintenance intervals are specified in the verified facts.

Are the detector flow cell and column oven included in the base delivery, and what accessories are needed?

The verified facts do not list included accessories or a column oven; the system is described as a GPC/SEC system with a deuterium lamp detector and 1024-element array. Confirm with the vendor whether the flow cell, columns, and solvent delivery modules are part of the base configuration, as these are not specified in the available documentation.