IR ER Booster Digital
Technical Reference Summary
Covered Models & Document Scope
Sistema de vacío estándar S-Series Booster + Bomba de tornillo, tipo VPS 301.10, sistema estándar montado sobre bastidor con bomba de respaldo VSI 301 y bomba de vacío booster VWP 1001; variantes de 50 Hz y 60 Hz.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Suction capacity at 1 mbar (abs.) | 850 m3/h p.4 ↗ | VPS 301.10, 50 Hz |
| Suction capacity at 1 mbar (abs.) | 1000 m3/h p.4 ↗ | VPS 301.10, 60 Hz |
| Ultimate vacuum | 0.01 mbar (abs.) p.4 ↗ | VPS 301.10, 50 Hz |
| Ultimate vacuum | 0.007 mbar (abs.) p.4 ↗ | VPS 301.10, 60 Hz |
| Nominal suction capacity (backing pump VSI 301) | 300 m3/h p.4 ↗ | VSI 301, 50 Hz |
| Nominal suction capacity (backing pump VSI 301) | 360 m3/h p.4 ↗ | VSI 301, 60 Hz |
| Power consumption | 5–6 kW p.3 ↗ | within 0.2 to 6 mbar (abs.) |
| Suction capacity range | Up to 800+ m3/h p.3 ↗ | 50 Hz, vacuum range 0.2 to 6 mbar (abs.) |
| Suction capacity range | Up to 900+ m3/h p.3 ↗ | 60 Hz, vacuum range 0.2 to 6 mbar (abs.) |
| Ultimate pressure | < 0.01 mbar (abs.) p.3 ↗ |
Operating Limits
- Ultimate pressure: < 0.01 mbar (abs.) p.3 ↗
- Ultimate vacuum at 50 Hz: 0.01 mbar (abs.) p.4 ↗
- Ultimate vacuum at 60 Hz: 0.007 mbar (abs.) p.4 ↗
- Operating vacuum range: 0.2 to 6 mbar (abs.) p.3 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-3 p.4 ↗ | VPS | System series: booster + screw pump standard vacuum system |
| 4-6 p.4 ↗ | 301 | System size designation |
| 7-8 p.4 ↗ | .10 | System variant (frame-mounted standard system) |