Product introduction and key features of the chiller
Specp. 2
Technical data according to DIN 12876
p. 2table, 12 rows
p. 1table, 31 rows
Technical data according to DIN 12876
Parameter
Value
max. cooling water pressure
6 bar
min. filling capacity
3,8 l
Volume of expansion
1,7 l
Overall dimensions WxDxH **
350x496x622 mm
Net weight
56 kg
Power supply requirement
220-240V 1~/2~ 50/60Hz
max. current
14,5 A
Fuse
16 A
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
S592998
** Please respect space requirements. See operating conditions at www.huber-online.com
Unichiller P010w-H — Technical data according to DIN 12876
Parameter
Value
Order-No.
3050.0007.01
Operating temperature range
-20...100 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Temperature stability at -10°C
0,2 K
Interface digital
Ethernet, USB (Host u. Device), RS232
Safety classification
III / FL
Heating power at 240V
2,1 kW
Heating power at 230V
2 kW
Heating power at 220V
1,8 kW
Cooling power at ambient temperature +20°C at 15°C
1 kW
Cooling power at ambient temperature +20°C at 0°C
0,8 kW
Cooling power at ambient temperature +20°C at -10°C
0,5 kW
Cooling power at ambient temperature +20°C at -20°C
0,15 kW
Refrigeration machine
water-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Refrigerant quantity
0,2 kg
CO2 equivalent
0,3 t
UN-number
UN 2857
Circulation pump
B
max. delivery
25 l/min
max. delivery pressure
2,5 bar
Delivery at 0,5 bar
21 l/min
Delivery at 1,0 bar
17 l/min
Delivery at 1,5 bar
11 l/min
Delivery at 2,0 bar
6 l/min
Pump connection
G3/4 male
Cooling water connection
G1/2 male
min. cooling water differential pressure
1 bar
Cooling power values are given at ambient temperature +20°C for the respective coolant temperatures 15°C, 0°C, -10°C and -20°C.
Engineering Facts
12 facts · every claim linked to a page
Installation
The chiller requires cooling water with a minimum differential pressure of 1 bar to operate correctly.
Ensures the cooling water supply can provide adequate flow through the water-cooled refrigeration circuit.
Source
“min. cooling water differential pressure 1 bar”
Installation
The unit is designed for cooling water intake temperatures between 5°C and 20°C, and pipes must be insulated if condensation occurs.
Prevents condensation damage and ensures specified cooling performance.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C. When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Operation
Cooling capacity drops as cooling water temperature rises, and the required cooling water flow rate may increase.
Affects sizing of the cooling water supply and expected performance at elevated water temperatures.
Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Safety
The plastic pump is not resistant to acetone or polyglycols, so these fluids must be avoided or a more resistant pump ordered.
Prevents chemical attack and premature pump failure when selecting heat transfer fluid.
Source
“Special Case: Acetone and Polyglycol: The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation
For freeze protection, water should be mixed with glysantine or ethylene glycol rather than relying on pure water.
Avoids freezing and damage in the cooling circuit when operating near or below 0°C.
Source
“It is recommended that water is mixed with either glysantine or ethylene glycol for freeze protection.”
Cumplimiento
Voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.
Ensures the power supply stays within safe operating limits and avoids invalid combinations.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation
Three-phase devices with current consumption less than 63A are supplied with cable but without a plug.
Requires the installer to provide a suitable plug and connection for three-phase power.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation
The unit has IP20 protection, so it must be installed in a dry environment protected from water ingress.
Prevents electrical hazards and ensures compliance with environmental conditions.
Source
“Degree of Protection IP20”
Selection
The refrigerant R-449A has a GWP of 1397 and a CO2 equivalent of 0.3 t, which matters for environmental compliance.
Affects refrigerant handling regulations and environmental reporting obligations.
Source
“Global Warming Potential (GWP) 1397”
Operation
The pump delivers 21 l/min at 0.5 bar but only 6 l/min at 2.0 bar, so system pressure drop directly reduces flow.
Helps evaluate whether the pump can meet the flow demand of a high-pressure-drop application.
Source
“Delivery at 0,5 bar 21 l/min”
Installation
The maximum cooling water pressure is 6 bar, so the supply must be regulated below this limit.
Prevents damage to the cooling water circuit from overpressure.
Source
“max. cooling water pressure 6 bar”
Operation
The ambient temperature must remain between 5°C and 40°C for safe and reliable operation.
Ensures the unit operates within its designed environmental envelope.