Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — L-BV5 2BV5161 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Familia de bombas de vacío de anillo líquido L-BV5, hoja de datos para el tamaño 2BV5 161. Variantes: versiones de material en fundición (K) y acero inoxidable (H), 50/60 Hz, diversos rangos de tensión, eficiencia IE3 o NP, versiones ATEX categoría 2G disponibles.

Technical Data

Parameter Value Condición
Suction capacity 300 m³/h p.2 ↗ 2BV5 161, 50 Hz, 500 V
Suction capacity 316 m³/h p.2 ↗ 2BV5 161, 60 Hz, 575 V
Rated current 23,5 A p.2 ↗ 2BV5 161, 50 Hz, 500 V
Rated current 22,5 A p.2 ↗ 2BV5 161, 60 Hz, 575 V
Power 12,4 kW p.2 ↗ 2BV5 161, 50 Hz, 500 V
Power 16,0 kW p.2 ↗ 2BV5 161, 60 Hz, 575 V
Service factor 1,21 - p.2 ↗ 2BV5 161, 50 Hz, 500 V
Service factor 1,03 - p.2 ↗ 2BV5 161, 60 Hz, 575 V
Efficiency IE3 - p.2 ↗ 2BV5 161, 50 Hz, 500 V
Efficiency NP - p.2 ↗ 2BV5 161, 60 Hz, 575 V
Sound pressure level 74 dB(A) p.2 ↗ 2BV5 161, 50 Hz, 500 V
Sound pressure level 75 dB(A) p.2 ↗ 2BV5 161, 60 Hz, 575 V
Weight 300 kg p.2 ↗ 2BV5 161, 50 Hz, 500 V
Weight 316 kg p.2 ↗ 2BV5 161, 60 Hz, 575 V
Ultimate pressure 33 mbar abs. p.1 ↗ general
Cavitation-free operation down to 80 mbar abs. p.1 ↗ general
Protection rating IP55 - p.1 ↗ standard motor
Insulation class F - p.2 ↗ standard motor
Max. additional water carry-over 6 m³/h p.2 ↗ 50 Hz and 60 Hz
Max. back pressure 1300 mbar abs. p.2 ↗ 50 Hz and 60 Hz

Operating Limits

  • Minimum inlet pressure: 33 mbar abs. p.1 ↗
  • Cavitation-free operation down to: 80 mbar abs. p.1 ↗
  • Max. additional water carry-over: 6 m³/h p.2 ↗
  • Max. back pressure: 1300 mbar abs. p.2 ↗
  • Protection rating: IP55 p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BV5 Product family: liquid ring vacuum pump
5-7 p.2 ↗ 161 Size designation
field after 2BV5 p.2 ↗ K Material variant: cast iron housing, bronze impeller
field after 2BV5 p.2 ↗ C Material variant: cast iron housing, CrNi steel impeller
field after 2BV5 p.2 ↗ H Material variant: CrNi steel housing and impeller
voltage field p.2 ↗ 1 Voltage code: 190-210 Δ / 190-210 YY / 220-240 Δ / 380-420 Y
voltage field p.2 ↗ 6 Voltage code: 190-210 YY / 220-240 Δ / 380-420 Y / 220-240 YY / 440-480 Y
voltage field p.2 ↗ 7 Voltage code: 380-420 Δ / 660-725 Y / 440-480 Δ / 460 Δ