Agilent Technologies MagnisDx NGS Prep System
Agilent Technologies MagnisDx NGS Prep System — Secuenciación de nueva generación con Temperatura 15 °C.
El Sistema de preparación NGS MagnisDx (K1007A) es una plataforma automatizada de manipulación de líquidos para uso IVD, que procesa muestras de ácido nucleico humano a partir de ARN total o gDNA fragmentado mediante preparación de bibliotecas y enriquecimiento de dianas. Integra un calentador de 75 °C, agitador, pantalla táctil LCD e interfaces USB/LAN, y está validado con kits Agilent Magnis NGS. Se diferencia del Magnis (G9710A) de uso exclusivo en investigación por su etiquetado de diagnóstico in vitro.
Agilent Technologies NGS Automation Platforms Series — Model Comparison & Selection
| Modelo | Temperatura, °C | Operating temperature, °C | Acoustic pressure, dB | Electrostatic discharge immunity, volts | Labware temperature stability, °C | Library storage duration after run, hours |
|---|---|---|---|---|---|---|
| MagnisDx NGS Prep System Actual | 15 | 75 | 70 | 8000 | 120 | 72 |
| Magnis NGS Prep System | 15 | 75 | 70 | 8000 | 120 | 72 |
Especificaciones completas
| Temperatura | 15 °C |
| Inmunidad a descargas electrostáticas | 8000 volts |
| Duración de almacenamiento de la librería tras la ejecución | 72 hours |
| Capacidad de elevación | 100 kg |
| Ajustes de temperatura | 75 °C |
| Duración del ciclo extendido de descontaminación UV | 2 hours |
| Duración del ciclo rápido de descontaminación UV | 30 minutes |
| Shaker maximum speed mfr | 1800 % rpm |
| Intended use mfr | Automated liquid handling system for NGS library |
| End result mfr | Target-enriched DNA library ready for sequencing |
| Validated reagents mfr | Agilent Magnis NGS kits kits |
| Materials provided mfr | Instrument with preloaded touchscreen software; |
| Cleaning supplies mfr | Alcohol wipes; dry, lint-free, scratch-free wipe |
| Dimensions, instrument door closed (H × D × W) mfr | 71 cm |
| Dimensions, instrument door open (H × D × W) mfr | 107 cm |
| Clearance, sides mfr | 4 inches |
| Clearance, back mfr | 7 inches |
| Clearance, front mfr | 2 inches |
| Clearance, top mfr | 44 inches |
| Lifting capacity for moving instrument mfr | 220 lbs |
| Maximum shaker speed mfr | 1 % tr/min |
| Maximum speed (rpm) mfr | 1800 |
| ISM Classification mfr | 1 |
| Diluted bleach (10%) wipes mfr | Surface-cleaning of the instrument deck deck |
| Alcohol (70%) wipes mfr | Surface-cleaning of the instrument exterior and |
| Dry, lint-free, scratch-free, laboratory wipes mfr | Surface-cleaning of the barcode scanner window w |
| White mfr | Ready Ready |
| Blue mfr | Ready Ready |
| Green mfr | Running Running |
| Red mfr | Error Error |
| Set up and run protocols mfr | Yes Yes |
| Update the number of PCR cycles during run setup mfr | No Yes Yes |
| Edit user accounts of other users mfr | No Yes Yes |
| Install firmware updates mfr | No Yes Yes |
| Delete diagnostic reports mfr | No Yes Yes |
| Bypass reagent expiration error mfr | No Yes* |
| Home icon mfr | Provides access to the Home screen. Press to exi |
| User name mfr | Displays the user name of the currently logged-i |
| Door status mfr | Indicates the position and lock status of the in |
| Error icon mfr | Indicates the occurrence of a system error or fa |
| Time and date mfr | Displays the time and date according to the syst |
| User Management mfr | Opens the “User Management screen” for viewing u |
| System Settings mfr | Ouvre la Fenêtre « System Settings » permettant |
| Export mfr | Opens the “Export Files screen” for exporting po |
| Auto Teaching mfr | Ouvre la Fenêtre « Auto Teach » permettant d’exé |
| Hardware Usage Tracking mfr | Ouvre la Fenêtre « Hardware Usage Tracking » per |
| Date & Time Settings mfr | Opens the “Date & Time Settings screen” for sett |
| Chiller Setting mfr | Ouvre la Fenêtre « Chiller Setting » permettant |
| Other Settings mfr | Opens the “Other Settings screen” which has a se |
| Firmware Update mfr | Opens the “Firmware Update screen” for installin |
| Lift capacity required for moving mfr | 100 kg |
| Side clearance mfr | 10 cm |
| Back clearance mfr | 18 cm |
| Chiller hold time before auto shutoff mfr | 2 hours |
| Clearance side mfr | 10 cm |
| Clearance back mfr | 18 cm |
| Clearance front mfr | 5 cm |
| Clearance top mfr | 111 cm |
| ESD threshold mfr | 8 volts |
| Module du thermocycleur mfr | Température maximale du bloc thermique thermique |
| Module chauffage/agitateur/aimant mfr | Vitesse maximale maximale |
| Module refroidisseur mfr | Plage de température rature |
| Prise d’alimentation mfr | Puissance maximale maximale |
| Connecteurs d’entrée/de sortie (E/S) mfr | Tension nominale maximale maximale |
| Système mfr | Poids Poids |
| Conditions environnementales* mfr | Altitude Altitude |
| Configuration et exécution de protocoles mfr | Oui Oui |
| Affichage des données des protocoles exécutés par eux-mêmes mfr | Oui Oui |
| Mise à jour du nombre de cycles de réaction de polymérisation en chaîne lors de la configuration du protocole mfr | Non Oui Oui |
| Affichage des données des protocoles exécutés par d’autres utilisateurs mfr | Non Oui Oui |
| Modification des comptes d’autres utilisateurs mfr | Non Oui Oui |
| Installation des mises à jour du firmware mfr | Non Oui Oui |
| Installation des mises à jour de protocoles mfr | Non Oui Oui |
| Suppression des rapports de diagnostic mfr | Non Oui Oui |
| Modification de la version par défaut des protocoles mfr | Non Oui Oui |
| Contournement de l’erreur de péremption du réactif mfr | Non Oui* |
| Date & time Settings mfr | Ouvre la Fenêtre « Date & Time Settings » permet |
| Lingettes à l'eau de Javel diluée (10 %) mfr | Nettoyage en surface du plateau de l'instrument |
| Lingettes imbibées d'alcool (70 %) mfr | Nettoyage en surface de l'extérieur et du platea |
| Lingettes de laboratoire douces, non pelucheuses et sèches mfr | Nettoyage de surface de la fenêtre du lecteur de |
| Blanc mfr | « Ready » |
| Bleu mfr | « Ready » |
| Vert mfr | « Running » |
| Rouge mfr | « Error » |
| Icône en forme de maison mfr | Permet d’accéder à la fenêtre « Home ». Appuyez |
| Nom d’utilisateur mfr | Affiche le nom de l’utilisateur actuellement con |
| État de la porte mfr | Indique la position et l’état de verrouillage de |
| UV tube lifetime mfr | 630 heures |
| Post-run chiller hold time mfr | 2 heures |
| Post-run sample hold time mfr | 72 heures |
| Lift capacity required mfr | 100 kg |
| Rear clearance mfr | 18 cm |
| Peso | 95 kg |
| Dimensions, instrument door closed (height × depth × width) mfr | 71 cm |
| Dimensions, instrument door open (height × depth × width) mfr | 107 cm |
| Dimensions, instrument door closed (Height × Depth × Width) mfr | 71 cm |
| Dimensions, instrument door open (Height × Depth × Width) mfr | 107 cm |
| Consumo de potencia | 1000 W |
| Alimentación | 100...240 VAC |
| AC voltage mfr | 100...240 |
| AC frequency mfr | 50 Hz |
| ISM classification mfr | 1 A |
| Power supply frequency mfr | 50 Hz |
| Maximum voltage rating mfr | 3.3 VDC |
| USB 2.0 port maximum voltage rating mfr | 5 VDC |
| Control interface mfr | LCD touchscreen touchscreen |
| USB 2.0 port maximum nominal voltage mfr | 5 VCC |
| LAN port maximum nominal voltage mfr | 3.3 VCC |
| LAN port maximum voltage rating mfr | 3.3 VDC |
| USB port voltage mfr | 5 VDC |
| Ethernet port voltage mfr | 3.3 VDC |
| USB 2.0 port maximum rated voltage mfr | 5 VCC |
| LAN port maximum rated voltage mfr | 3.3 VCC |
| View data from their own protocol runs mfr | Yes Yes |
| View data from protocol runs of other users mfr | No Yes Yes |
| Install protocol updates mfr | No Yes Yes |
| Change default protocol version mfr | No Yes Yes |
| Protocol Update mfr | Ouvre la Fenêtre « Protocol Update » permettant |
| Electrostatic discharge threshold affecting USB mfr | 8000 volts |
| Install firmware and protocol updates mfr | No Yes Yes |
| Starting material mfr | Total RNA or fragmented genomic DNA purified fro |
| Presión acústica | 70 dBA |
| Estabilidad de temperatura del material de laboratorio | 120 °C |
| Temperatura de almacenamiento de la librería tras la ejecución | 12 °C |
| Altitud máxima | 2000 m |
| Temperatura máxima | 75 °C |
| Temperatura mínima del bloque térmico | 4 °C |
| Presión sonora | 70 dBA |
| Operating humidity mfr | 30...70 condensing |
| Humidity mfr | 30 condensing |
| Maximum altitude for instrument operation mfr | 2000 m |
Descripción
Construcción y posicionamiento en la serie
El Sistema de preparación NGS MagnisDx es la variante de diagnóstico in vitro (IVD) de la serie Magnis NGS Prep; su hermano, el Sistema de preparación NGS Magnis (G9710A), está etiquetado para uso exclusivo en investigación. Ambos son sistemas automatizados de manipulación de líquidos destinados a la preparación de bibliotecas NGS y/o enriquecimiento de dianas de muestras de ácido nucleico humano. El MagnisDx se distingue por su etiquetado IVD y se suministra con software preinstalado en pantalla táctil, cable de alimentación y certificado de prueba funcional. El instrumento incluye un calentador con temperatura máxima de 75 °C, un agitador, una pantalla táctil LCD para control y puertos USB 2.0 y LAN.
Rango de trabajo y entrada de muestra
El sistema acepta ARN total o ADN genómico fragmentado purificado de muestras celulares o tisulares, muestras de sangre o muestras FFPE. El resultado final es una biblioteca de ADN enriquecida en dianas lista para secuenciación. Los reactivos validados son los kits Agilent Magnis NGS. El calentador admite procesos de hasta 75 °C y el agitador proporciona mezcla; la velocidad máxima del agitador se indica como 1 tr/min en las especificaciones disponibles, lo que es insuficiente para definir un rango de mezcla utilizable y, por lo tanto, no se caracteriza más aquí.
Control, interfaces y operación
La operación se realiza mediante una pantalla táctil LCD con software preinstalado. El puerto USB 2.0 tiene una tensión nominal máxima de 5 V y el puerto LAN tiene una tensión nominal máxima de 3.3 V. La guía del usuario (GEN MAN K1007 90000, 90010, 90011) cubre tanto los sistemas Magnis como MagnisDx; los procedimientos detallados de instalación, conexión y operación se proporcionan en esos documentos. No se enumeran certificados ni aplicaciones en los hechos verificados.
Integration & Operating Notes
El puerto USB 2.0 está clasificado para una tensión nominal máxima de 5 V. Conectar un dispositivo que suministre o aplique una tensión superior puede dañar el puerto o el instrumento. Verifique que cualquier periférico o adaptador USB sea compatible con este límite antes de la conexión.
El puerto LAN está clasificado para una tensión nominal máxima de 3.3 V. Utilice únicamente equipos Ethernet estándar que cumplan con este límite; los inyectores PoE no conformes o los cables mal conectados pueden exceder la clasificación y causar daños.
El calentador tiene una temperatura máxima de 75 °C. Los protocolos de proceso deben validarse dentro de este límite; excederlo puede degradar las muestras o los reactivos y está fuera del rango operativo especificado del instrumento.
El sistema está validado con kits Agilent Magnis NGS. La sustitución por otros reactivos puede producir resultados no válidos y no está respaldada por el etiquetado IVD. Asegúrese de la compatibilidad del kit antes de iniciar una ejecución.
Los materiales proporcionados incluyen toallitas con alcohol y toallitas secas, sin pelusa y sin rayas para la limpieza. Evite limpiadores abrasivos o a base de disolventes que puedan dañar la pantalla táctil o las superficies del instrumento. Siga la guía del usuario para la frecuencia y el procedimiento de limpieza.
Selection & Integration Q&A
Elija el MagnisDx (K1007A) cuando el flujo de trabajo requiera uso de diagnóstico in vitro, ya que está etiquetado para IVD. El Magnis (G9710A) es para uso exclusivo en investigación y no debe utilizarse para procedimientos de diagnóstico. Ambos automatizan la preparación de bibliotecas NGS y el enriquecimiento de dianas con kits Agilent Magnis NGS.
El puerto USB 2.0 tiene una tensión nominal máxima de 5 V y el puerto LAN tiene una tensión nominal máxima de 3.3 V. Asegúrese de que cualquier dispositivo conectado o equipo de red no exceda estas clasificaciones para evitar daños.
El suministro base incluye el instrumento con software preinstalado en pantalla táctil, un cable de alimentación y un certificado de prueba funcional. La limpieza requiere toallitas con alcohol y toallitas secas, sin pelusa y sin rayas, que no se enumeran como incluidas y deben suministrarse por separado.