FRG-700 and FRG-702 Vacuum Gauge User Manual

Contenido

  1. Overview pp. 2-3
    Legal notices and table of contents
  2. Overview pp. 4-5
    Basic operating instructions and use guidance
  3. Overview pp. 6-7
    Definitions, terminology and manual conventions
  4. Warning pp. 8-9
    Safety symbols and their meanings
  5. Warning pp. 10-13
    Improper use, safety rules and disposal
  6. Services pp. 14-15
    Service contact and technical information
  7. Overview pp. 16-17
    Gauge design and technical specifications
  8. Spec pp. 18-23
    Detailed specifications, dimensions and notes
  9. Procedure pp. 24-27
    Mounting, magnet unit removal and installation warnings
  10. Procedure pp. 28-29
    Wiring and electrical connection instructions
  11. Procedure pp. 30-33
    Operating notes and gauge adjustment procedures
  12. Procedure pp. 34-43
    Removal, cleaning and disassembly of FRG-700/702
  13. Procedure pp. 44-45
    Fault diagnosis and spare parts
  14. Ordering pp. 46-51
    Spare parts list, technical info and contact details
  15. p. 16 table, 7 rows
  16. p. 17 table, 31 rows
  17. p. 45 table, 5 rows
  18. p. 18 table, 31 rows
  19. p. 15 table, 24 rows
  20. p. 29 table, 3 rows
  21. p. 46 table, 5 rows
  22. p. 5 table, 11 rows

Part numbers

Part numberDescription
FRG-700 (FPM sealed)
FRG-702 (all-metal)
FRG700KF25DN 25 ISO-KF
FRG702KF25DN 25 ISO-KF
FRG700CF35DN 40 CF-C
FRG702KF40DN 40 ISO-KF
FRG702CF35DN 40 CF-C

Table 1 Technical Specifications

SpecificationsValue
Measuring range (air, N2)5×10-9 ... 1000 mbar
Accuracy (N2)≈±30%
in the range 1×10-8 ... 100 mbar
Reproducibility≈±5%
in the range 1×10-8 ... 100 mbar
Gas type dependenceSee page 21
Output signal (measuring signal)
Voltage range0 ... +10.5 V
Measuring range1.82 ... 8.6 V
Voltage vs. pressurelogarithmic, 0.6 V / decade
Error signal<0.5 V no supply
>9.5 V Pirani measurement element
defective (filament rupture)
Output impedance2×10 Ω
Minimum loaded impedance10 kΩ, short-circuit proof
Response time (pressure dependent)
p > 10-6 mbar<10 ms
p = 10-8 mbar≈1000 ms
Gauge identification85 kΩ referenced to supply common
Status
p > 10-2 mbarPirani-only mode
p < 10-2 mbarCold cathode not ignited
Pirani-only mode
p < 10-2 mbarCold cathode ignited
Combined Pirani /
cold cathode mode
LampPin 6
Low = 0 V
Low = 0 V
High = 15 ... 30 VDC
High voltage on (LED on)

Table 4 Spare Parts for FRG-700

Pos.DescriptionOrdering number
12 13a 11 10aMaintenance kit, consisting of: 1× support ring 1× O-ring FPM ø3.69×1.78 1× O-ring FPM ø10.82×1.78 3× ignition aidFRG700MAINT
13 12 13a 11 10a 10Repair kit, consisting of: 1× Pirani element 1× support ring 1× O-ring FPM ø3.69×1.78 1× O-ring FPM ø10.82×1.78 3× ignition aid 1× anode, completeFRG700REPR
10aSet of ignition aids, comprising: 10× ignition aidFRG700IGN
Mounting tool for ignition aidFRG700IGNT
Measuring system DN 25 ISO-KF flange DN 40 CF-F flangeFRG700MEAS25 FRG700MEAS40

Table 1 Technical Specifications (continued)

SpecificationsValue
Supply
WARNING
The gauge may only be connected to power supplies, instruments or control devices that conform to the requirements of a grounded extra-low voltage (SELV). The connection to the gauge has to be fused1).
Supply voltage at the gauge15.0 ... 30.0 VDC (ripple ≤1 Vpp)
Power consumption≤2 W
Fuse1)≤1 AT
The minimum voltage of the power supply must be increased proportionally to the length of the sensor cable.
Voltage at the supply unit with maximum line length16.0 ... 30.0 VDC (ripple ≤1 Vpp)
Adjustment<HV> potentiometer at <10-4 mbar
<ATM> potentiometer at atmospheric pressure
Electrical connection
Sensor cableFCC68 female, 8 poles
Line length8 conductors plus shielding ≤50 m (8x0.14 mm²)
Operating voltage≤3.3 kV
Operating current≤500 µA
Grounding concept
Vacuum connection-signal commonsee paragraoh Electrical Connection (page 28)
Supply common-signal commonconnected via 10 kΩ (max. voltage differential with respect to safety ±50 V with respect to accuracy ±10 V)
conducted separately
Materials exposed to vacuum
Vacuum connectionstainless steel
Measuring chamberstainless steel
Feedthroughceramic
Internal sealsFPM 75
AnodeAg, Cu, soft solder (Sn, Ag)
Ignition aidMo
Pirani measuring tubestainless steel
Pirani filamentNi, Au
FRG-700
FRG-702
W

1) Agilent controller fulfill these requirements.

Содержание

РазделСтраница
Technical Information
Product Description16
Technical Specifications17
FRG-700 and FRG-702 Outline20
Installation24
Vacuum Connection24
Removing the Magnet Unit (only for Gauges with CF Flanges)27
Electrical Connection28
Use With an Agilent Controller28
Use With Another Control Device28
Operation29
Adjusting the Gauge32
Deinstallation34
Cleaning FRG-70035
Replacing the Pirani element36
Cleaning FRG-700, Replacing Parts36
Disassembling FRG-70037
Reassembling FRG-70038
Cleaning FRG-70239
Cleaning FRG-702, Replacing Parts40
Disassembling FRG-70241
Reassembling FRG-70242
Troubleshooting44
Spare Parts45

Table 2

PressureLamp on the gaugeOperating modePin 6
p > 1x10-2 mbarPirani-only modeLow = 0 V
p < 1x10-2 mbarCold cathode not ignitedPirani-only modeLow = 0 V
p < 1x10-2 mbarCold cathode ignitedCombined Pirani / cold cathode modeHigh = 15 ... 30 VDC

Table 5 Spare Parts for FRG-702

Pos.DescriptionOrdering number
11 12 10aMaintenance kit, consisting of: 1× seal HN 100 (9x1.6) 1× centering ring 3× ignition aidFRG702MAINT
13 13a 13b 9a 10 10a 11 12Repair kit, consisting of:: 1× Pirani element with glass feedthrough 1× screw fitting 1× copper seal 1× anode extension piece 1× anode, complete 3× ignition aid 1× seal HN 100 (9x1.6) 1× centering ringFRG702REPR
10aSet of ignition aids, comprising: 10× ignition aidFRG700IGN
Mounting tool for ignition aidFRG700IGNT
Measuring system DN 25 ISO-KF flange DN 40 CF-F flangeFRG702MEAS25 FRG702MEAS40

Instructions for Use

РазделСтраница
About this manual6
Validity6
Definitions and terminology7
Definition of Caution, Warning and Note7
Warning Symbols8
Safety10
Proper use10
Improper use11
Safety guideline for FRG-700 and FRG-70212
Disposal13
Service14

Engineering Facts

14 facts · every claim linked to a page
Selection

The gauge covers a very wide measuring range from 5×10-9 to 1000 mbar, so one sensor can span UHV to rough vacuum.

Determines whether a single gauge can replace separate Pirani and cold-cathode heads across the whole process range.

Source
“Measuring range (air, N2) 5×10-9 ... 1000 mbar”
Selection

Accuracy is only about ±30% in the 1×10-8 to 100 mbar range, so it is not a precision measurement device.

Sets expectations for process control and whether a higher-accuracy gauge is needed.

Source
“≈±30% in the range 1×10-8 ... 100 mbar”
Installation

The gauge must be powered from a grounded SELV supply and the connection must be fused at ≤1 AT.

Defines the electrical supply and protection requirements before wiring the sensor cable.

Source
“The gauge may only be connected to power supplies, instruments or control devices that conform to the requirements of a grounded extra-low voltage (SELV).”
Installation

Supply voltage at the gauge must be 15.0 to 30.0 VDC with ripple ≤1 Vpp, and must be raised for long cables.

Prevents undervoltage on long sensor cable runs up to 50 m.

Source
“15.0 ... 30.0 VDC (ripple ≤1 Vpp)”
Installation

The sensor cable is limited to 50 m using 8×0.14 mm² conductors with FCC68 female connector.

Constrains cable routing and controller placement during installation.

Source
“≤50 m (8x0.14 mm²)”
Installation

For KF connections a conductive metallic clamping ring is required to achieve protective grounding.

Ensures protective earth continuity required by EN 61010 for safety.

Source
“For gauges with KF connections, use a conductive metallic clamping ring.”
Installation

KF flange connections with elastomer seals cannot withstand overpressure above 2.5 bar, so O-rings with outer centering ring must be used.

Prevents seal failure and process media leakage in pressurized systems.

Source
“KF flange connections with elastomer seals (e.g. O-rings) cannot withstand such pressures.”
Installation

The gauge may be mounted in any orientation, but horizontal to upright is preferred to keep condensates and particles out.

Guides mounting position to reduce contamination and extend maintenance intervals.

Source
“The gauge may be mounted in any orientation.”
Installation

The gauge must be installed so the <HV> and <ATM> trimmer potentiometers remain accessible with a screwdriver for adjustment.

Allows field adjustment after installation without removing the gauge.

Source
“be sure to install it so that the <HV> and <ATM> trimmer potentiometers can be accessed with a screw driver.”
Operation

A stabilizing time of about 10 minutes is required, and the gauge should be left on permanently regardless of pressure.

Affects startup procedure and power/control design for continuous operation.

Source
“Allow for a stabilizing time of approx. 10 min. Once the gauge has been switched on, permanently leave it on irrespective of the pressure.”
Operation

The cold cathode circuit only activates below 1×10-2 mbar; above that the gauge runs in Pirani-only mode.

Explains the status output behavior and the crossover point between measuring principles.

Source
“The cold cathode measuring circuit is controlled by the Pirani circuit and is activated only at pressures <1×10-2 mbar”
Maintenance

Continuous operation in the 10-4 to 10-2 mbar range causes severe contamination and reduced uptime, while below 1×10-6 mbar the gauge can run over a year without cleaning.

Informs process operating point choice and maintenance planning.

Source
“Continuous operation in the range of 10-4 mbar ... 10-2 mbar can cause severe contamination as well as reduced up-time and maintenance cycles.”
Safety

Helium used in leak testing can cause electric arcing that damages the electronics, so the product must be switched off and the electronics unit removed before tightness tests.

Prevents electronics damage during helium leak testing of the installed system.

Source
“Before performing any tightness tests put the product out of operation and remove the electronics unit.”
Maintenance

Gauge failures due to contamination or wear and expendable parts such as the filament are not covered by warranty.

Affects lifecycle cost and spare-part stocking decisions.

Source
“Gauge failures due to contamination or wear and tear as well as expendable parts (e.g. filament) are not covered by the warranty.”