Technical Data Sheet — G-BH1 2BH1400 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Fiche technique 2BH1 400, ventilateur à canal latéral en configuration ATEX (G-BH1 N). Couvre les catégories ATEX 3GD, 3/2D et 3/2G en tant que machines à tension fixe pour 50 Hz et 60 Hz ; 3/2G disponible uniquement en versions 50 Hz ou 60 Hz. Code de commande 2BH1…-1.□.□-Z avec Z=M34, M71, M74/75.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 400 / 690 V p.2 ↗ | 2BH1400, 50 Hz, Δ/Y |
| Rated current | 2,25 / 1,30 A p.2 ↗ | 2BH1400, 50 Hz, Δ/Y |
| Power | 1,5 hp p.2 ↗ | 2BH1400, 50 Hz |
| Max. vacuum | -76 inch H2O p.2 ↗ | 2BH1400, 50 Hz |
| Max. differential pressure | 80 inch H2O p.2 ↗ | 2BH1400, 50 Hz |
| Sound pressure level | 61 dB(A) p.2 ↗ | 2BH1400, 50 Hz |
| Rated voltage | 460 V p.2 ↗ | 2BH1400, 60 Hz, Δ |
| Rated current | 2,25 A p.2 ↗ | 2BH1400, 60 Hz, Δ |
| Power | 1,7 hp p.2 ↗ | 2BH1400, 60 Hz |
| Max. vacuum | -72 inch H2O p.2 ↗ | 2BH1400, 60 Hz |
| Max. differential pressure | 68 inch H2O p.2 ↗ | 2BH1400, 60 Hz |
| Sound pressure level | 61 dB(A) p.2 ↗ | 2BH1400, 60 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH1400 |
| Efficiency class | IE3 p.2 ↗ | motor, thermal class F |
Operating Limits
- ATEX category availability: 3GD and 3/2D as fixed voltage machines for 50 and 60 Hz; 3/2G only 50 Hz or 60 Hz versions p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 59 °F p.1 ↗
- Reference atmospheric pressure for performance curves: 29.92 inch Hg p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series G-BH1 side channel blower |
| 5-7 p.2 ↗ | 400 | Size 400 |
| field 1 p.2 ↗ | 1 | Version / generation |
| field 2 p.2 ↗ | A | ATEX category variant (A for 3/2G, D for 3/2D, G for 3GD) |
| field 3 p.2 ↗ | D | ATEX category 3/2D |
| field 3 p.2 ↗ | G | ATEX category 3GD |
| field 4 p.2 ↗ | 1 | Voltage code 230 Δ/400 Y (50 Hz) / 460 Y (60 Hz) |
| field 4 p.2 ↗ | 6 | Voltage code 400 Δ/690 Y (50 Hz) / 460 Δ (60 Hz) |
| field 4 p.2 ↗ | 5 | Voltage code 500 Δ (50 Hz) / 575 Δ (60 Hz) |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943