Technical Data Sheet — G-BH1 2BH1500 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 500: soplador de canal lateral en configuración ATEX (G-BH1 N), categorías 3GD, 3/2D y 3/2G, máquinas de tensión fija para 50 Hz y 60 Hz; código de pedido 2BH1…-1.□.□-Z con sustituciones de tensión/ATEX.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 Y V p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Rated current 3,00 / 1,73 Y A p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Power 2,0 hp p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Max. differential pressure (vacuum) -88 inch H2O p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Max. differential pressure (pressure) 72 inch H2O p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Sound level 64 dB(A) p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Weight 69 lbs p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
Degree of protection IP55 p.2 ↗ 2BH1500, 50 Hz, 3/2D, 3GD
ATEX category 3/2G p.2 ↗ 2BH1500, 50 Hz, 3/2G
Rated voltage 460 V p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Rated current 2,95 A p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Power 2,3 hp p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Max. differential pressure (vacuum) -68 inch H2O p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Max. differential pressure (pressure) 68 inch H2O p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Sound level 64 dB(A) p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Weight 69 lbs p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
Degree of protection IP55 p.2 ↗ 2BH1500, 60 Hz, 3/2D, 3GD
ATEX category 3/2G p.2 ↗ 2BH1500, 60 Hz, 3/2G

Operating Limits

  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 59 F p.1 ↗
  • Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
  • Degree of protection: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series / type: side channel blower G-BH1
5-7 p.2 ↗ 500 Size designation (2BH1 500)
field 1 p.2 ↗ 1 Version / generation field
field 2 p.2 ↗ D Voltage connection code: D = Δ connection (230 Δ/400 Y, 400 Δ/690 Y, 500 Δ); G = Y connection (460 Y, 575 Δ)
field 3 p.2 ↗ 1 Voltage variant: 230 Δ/400 Y (50 Hz) / 460 Y (60 Hz)
field 3 p.2 ↗ 6 Voltage variant: 400 Δ/690 Y (50 Hz) / 460 Δ (60 Hz)
field 3 p.2 ↗ 5 Voltage variant: 500 Δ (50 Hz) / 575 Δ (60 Hz)