Technical Data Sheet — G-BH1 2BH1610 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Fiche technique 2BH1 610 (soufflante à canal latéral G-BH1), tailles 1-5, 50 Hz et 60 Hz, moteurs standard et à tension alternative (variantes H, C, K, Q)
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated pressure (vacuum) | -200 mbar p.2 ↗ | 2BH1610 size 1, 50 Hz |
| Rated pressure (vacuum) | -170 mbar p.2 ↗ | 2BH1610 size 1, 60 Hz |
| Max. differential pressure (pressure) | 190 mbar p.2 ↗ | 2BH1610 size 1, 50 Hz |
| Max. differential pressure (pressure) | 150 mbar p.2 ↗ | 2BH1610 size 1, 60 Hz |
| Voltage | 345-415 / 600-720 Y V p.2 ↗ | 2BH1610 size 1, 50 Hz |
| Voltage | 380-480 D V p.2 ↗ | 2BH1610 size 1, 60 Hz |
| Current | 5,6 / 3,2 Y A p.2 ↗ | 2BH1610 size 1, 50 Hz |
| Current | 5,8 D A p.2 ↗ | 2BH1610 size 1, 60 Hz |
| Power | 2,2 kW p.2 ↗ | 2BH1610 size 1, 50 Hz |
| Power | 2,55 kW p.2 ↗ | 2BH1610 size 1, 60 Hz |
| Noise level | 73 dB(A) p.2 ↗ | 2BH1610 size 1, 50 Hz |
| Noise level | 76 dB(A) p.2 ↗ | 2BH1610 size 1, 60 Hz |
| Weight | 43 kg p.2 ↗ | 2BH1610 size 1 |
| Rated pressure (vacuum) | -420 mbar p.2 ↗ | 2BH1610 size 5, 50 Hz |
| Rated pressure (vacuum) | -440 mbar p.2 ↗ | 2BH1610 size 5, 60 Hz |
| Max. differential pressure (pressure) | 610 mbar p.2 ↗ | 2BH1610 size 5, 50 Hz |
| Max. differential pressure (pressure) | 670 mbar p.2 ↗ | 2BH1610 size 5, 60 Hz |
| Voltage | 345-415 D / 600-720 Y V p.2 ↗ | 2BH1610 size 5, 50 Hz |
| Voltage | 380-480 D V p.2 ↗ | 2BH1610 size 5, 60 Hz |
| Current | 16,7 D / 9,6 Y A p.2 ↗ | 2BH1610 size 5, 50 Hz |
| Current | 17,3 D A p.2 ↗ | 2BH1610 size 5, 60 Hz |
| Power | 7,5 kW p.2 ↗ | 2BH1610 size 5, 50 Hz |
| Power | 8,6 kW p.2 ↗ | 2BH1610 size 5, 60 Hz |
| Noise level | 71 dB(A) p.2 ↗ | 2BH1610 size 5, 50 Hz |
| Noise level | 75 dB(A) p.2 ↗ | 2BH1610 size 5, 60 Hz |
Operating Limits
- Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH1610 | Type/size designation (G-BH1 side channel blower, size 610) |
| field 1 p.2 ↗ | 1-5 | Size number (1, 2, 3, 4, 5) |
| field 2 p.2 ↗ | H / C / K / Q | Motor/voltage variant code |
| field 3 p.2 ↗ | 1 / 3 / 5 / 6 | Voltage range option number |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH1610-7HH17 p.2 ↗ | 2BH1610-7HH17 | size 1, 50/60 Hz, standard voltage | ||
| 2BH1610-1HH27 p.2 ↗ | 2BH1610-1HH27 | size 2, 50/60 Hz, standard voltage | ||
| 2BH1610-1HH37 p.2 ↗ | 2BH1610-1HH37 | size 3, 50/60 Hz, standard voltage | ||
| 2BH1610-1HH47 p.2 ↗ | 2BH1610-1HH47 | size 4, 50/60 Hz, standard voltage | ||
| 2BH1610-1HH57 p.2 ↗ | 2BH1610-1HH57 | size 5, 50/60 Hz, standard voltage | ||
| 2BH1610-7HC13 p.2 ↗ | 2BH1610-7HC13 | size 1, 50/60 Hz, 500/575 V | ||
| 2BH1610-1HC23 p.2 ↗ | 2BH1610-1HC23 | size 2, 50/60 Hz, 500/575 V | ||
| 2BH1610-1HC33 p.2 ↗ | 2BH1610-1HC33 | size 3, 50/60 Hz, 500/575 V | ||
| 2BH1610-1HC43 p.2 ↗ | 2BH1610-1HC43 | size 4, 50/60 Hz, 500/575 V | ||
| 2BH1610-1HC53 p.2 ↗ | 2BH1610-1HC53 | size 5, 50/60 Hz, 500/575 V |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943