Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH1 2BH1810 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Soplador de canal lateral G-BH1, hoja de datos 2BH1 810; abarca las variantes 2BH1810 con motores de 50 Hz y 60 Hz, motores de doble tensión D/Y y de tensión fija Y, y los códigos de motor de tensión alternativa H1/H6/H7/C3/C5/K1/K6/Q5.

Technical Data

Parameter Value Condition
Rated pressure -400 mbar p.2 ↗ 2BH1810-1HH27, 50 Hz
Max. differential pressure vacuum 400 mbar p.2 ↗ 2BH1810-1HH27, 50 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1810-1HH27, 50 Hz
Current 16,7 D / 9,6 Y A p.2 ↗ 2BH1810-1HH27, 50 Hz
Power 7,5 kW p.2 ↗ 2BH1810-1HH27, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1810-1HH27, 50 Hz
Weight 157 kg p.2 ↗ 2BH1810-1HH27, 50 Hz
Rated pressure -360 mbar p.2 ↗ 2BH1810-1HH27, 60 Hz
Max. differential pressure vacuum 330 mbar p.2 ↗ 2BH1810-1HH27, 60 Hz
Voltage 380-480 V p.2 ↗ 2BH1810-1HH27, 60 Hz
Current 17,3 A p.2 ↗ 2BH1810-1HH27, 60 Hz
Power 8,6 kW p.2 ↗ 2BH1810-1HH27, 60 Hz
Sound pressure level 76 dB(A) p.2 ↗ 2BH1810-1HH27, 60 Hz
Weight 157 kg p.2 ↗ 2BH1810-1HH27, 60 Hz
Rated pressure -430 mbar p.2 ↗ 2BH1810-1HH37, 50 Hz
Max. differential pressure vacuum 600 mbar p.2 ↗ 2BH1810-1HH37, 50 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1810-1HH37, 50 Hz
Current 28 D / 16,2 Y A p.2 ↗ 2BH1810-1HH37, 50 Hz
Power 11,0 kW p.2 ↗ 2BH1810-1HH37, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1810-1HH37, 50 Hz
Weight 172 kg p.2 ↗ 2BH1810-1HH37, 50 Hz
Rated pressure -460 mbar p.2 ↗ 2BH1810-1HH47, 50 Hz
Max. differential pressure vacuum 670 mbar p.2 ↗ 2BH1810-1HH47, 50 Hz
Voltage 345-415 / 600-720 Y V p.2 ↗ 2BH1810-1HH47, 50 Hz
Current 32,5 / 18,8 Y A p.2 ↗ 2BH1810-1HH47, 50 Hz

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1810 Type/size designation of the side channel blower
field 1 p.2 ↗ H / C / K / Q Motor voltage variant family (H = dual-voltage D/Y, C = 500/575 V Y, K = 200 YY / 230 D / 400 Y, Q = 475-525 V Y / 550-600 V Y)
field 2 p.2 ↗ 1 / 3 / 6 / 7 / 5 Motor voltage code within the family (e.g. H1, H6, H7, C3, C5, K1, K6, Q5)
field 3 p.2 ↗ □ Placeholder for the motor voltage code letter/number combination

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1810-1HH27 p.2 ↗ 2BH1810-1HH27 50 Hz / 60 Hz, 345-415 D / 600-720 Y (50 Hz), 380-480 V (60 Hz) 7.5 kW variant
2BH1810-1HH37 p.2 ↗ 2BH1810-1HH37 50 Hz / 60 Hz, 345-415 D / 600-720 Y (50 Hz), 380-480 D (60 Hz) 11.0 kW variant
2BH1810-1HH47 p.2 ↗ 2BH1810-1HH47 50 Hz / 60 Hz, 345-415 / 600-720 Y (50 Hz), 380-480 V (60 Hz) 15.0 kW variant
2BH1810-1HC23 p.2 ↗ 2BH1810-1HC23 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) 7.5 kW variant
2BH1810-1HC33 p.2 ↗ 2BH1810-1HC33 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) 11.0 kW variant
2BH1810-1HC43 p.2 ↗ 2BH1810-1HC43 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) 15.0 kW variant