Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — 2BH1830 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 830-1: soplador de canal lateral con motores IE3, tamaños 1, 2, 3, 50 Hz y 60 Hz, diversas variantes de tensión (K, Q y variantes de motor de tensión alternativa), números de pedido 2BH1830-1AK01, -1AK11, -1AK21, -1AK06, -1AK16, -1AK26, -1AQ03, -1AQ13, -1AQ23, -1AQ07, -1AQ17, -1AQ27, -1AQ06, -1AQ16, -1AQ26

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BH1830-1AK01, 50 Hz, Δ
Rated current 17,1 A p.2 ↗ 2BH1830-1AK01, 50 Hz, Δ
Rated power 4,6 kW p.2 ↗ 2BH1830-1AK01, 50 Hz
Max. pressure difference -150 mbar p.2 ↗ 2BH1830-1AK01, 50 Hz
Max. pressure difference 140 mbar p.2 ↗ 2BH1830-1AK01, 50 Hz
Sound pressure level 77 dB(A) p.2 ↗ 2BH1830-1AK01, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1830-1AK01, 50 Hz
Weight 112 kg p.2 ↗ 2BH1830-1AK01, 50 Hz
Rated voltage 190-210 / 380-420 V p.2 ↗ 2BH1830-1AK01, 60 Hz, YY/Δ
Rated current 19,6 / 9,8 A p.2 ↗ 2BH1830-1AK01, 60 Hz, YY/Δ
Rated power 5,3 kW p.2 ↗ 2BH1830-1AK01, 60 Hz
Max. pressure difference -120 mbar p.2 ↗ 2BH1830-1AK01, 60 Hz
Max. pressure difference 110 mbar p.2 ↗ 2BH1830-1AK01, 60 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH1830-1AK01, 60 Hz
Rated voltage 190-210 V p.2 ↗ 2BH1830-1AK11, 50 Hz, Δ
Rated current 23,5 A p.2 ↗ 2BH1830-1AK11, 50 Hz, Δ
Rated power 6,3 kW p.2 ↗ 2BH1830-1AK11, 50 Hz
Max. pressure difference -250 mbar p.2 ↗ 2BH1830-1AK11, 50 Hz
Max. pressure difference 230 mbar p.2 ↗ 2BH1830-1AK11, 50 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1830-1AK11, 50 Hz
Weight 122 kg p.2 ↗ 2BH1830-1AK11, 50 Hz
Rated voltage 190-210 V p.2 ↗ 2BH1830-1AK21, 50 Hz, Δ
Rated current 30,8 A p.2 ↗ 2BH1830-1AK21, 50 Hz, Δ
Rated power 8,6 kW p.2 ↗ 2BH1830-1AK21, 50 Hz
Max. pressure difference -290 mbar p.2 ↗ 2BH1830-1AK21, 50 Hz

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH1 Series / type: side channel blower
6-9 p.2 ↗ 830-1 Size designation

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1830-1AK01 p.2 ↗ 2BH1830-1AK01 K 50 Hz, 190-210 V Δ Size 1, IE3
2BH1830-1AK11 p.2 ↗ 2BH1830-1AK11 K 50 Hz, 190-210 V Δ Size 2, IE3
2BH1830-1AK21 p.2 ↗ 2BH1830-1AK21 K 50 Hz, 190-210 V Δ Size 3, IE3
2BH1830-1AK06 p.2 ↗ 2BH1830-1AK06 K 50 Hz, 220-240 V Δ / 380-420 V Y Size 1, IE3
2BH1830-1AK16 p.2 ↗ 2BH1830-1AK16 K 50 Hz, 220-240 V Δ / 380-420 V Y Size 2, IE3
2BH1830-1AK26 p.2 ↗ 2BH1830-1AK26 K 50 Hz, 220-240 V Δ / 380-420 V Y Size 3, IE3
2BH1830-1AQ03 p.2 ↗ 2BH1830-1AQ03 Q 50 Hz, 475-525 V Y Size 1, IE3
2BH1830-1AQ13 p.2 ↗ 2BH1830-1AQ13 Q 50 Hz, 475-525 V Y Size 2, IE3
2BH1830-1AQ23 p.2 ↗ 2BH1830-1AQ23 Q 50 Hz, 475-525 V Y Size 3, IE3