Technical Data Sheet — G-BH1 2BH1900 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 900: soplador de canal lateral en configuración ATEX (G-BH1 N), tamaños/variantes 2BH1900-1AD31-Z con Z=M71 (3/2G) y Z=M34/M74 (3/2D, 3GD), 50 Hz y 60 Hz, diversas tensiones; categorías ATEX 3/2G, 3/2D, 3GD.

Technical Data

Parameter Value Condition
Rated voltage 400 / 690 V p.2 ↗ 2BH1900, 50 Hz, Δ/Y
Rated voltage 460 V p.2 ↗ 2BH1900, 60 Hz, Δ
Current 20.0 / 11.6 A p.2 ↗ 2BH1900, 50 Hz, Δ/Y
Current 19.5 A p.2 ↗ 2BH1900, 60 Hz, Δ
Power 14.8 hp p.2 ↗ 2BH1900, 50 Hz
Power 16.9 hp p.2 ↗ 2BH1900, 60 Hz
Max. differential pressure vacuum -96 inch H2O p.2 ↗ 2BH1900, 50 Hz
Max. differential pressure vacuum -80 inch H2O p.2 ↗ 2BH1900, 60 Hz
Max. differential pressure pressure 92 inch H2O p.2 ↗ 2BH1900, 50 Hz
Max. differential pressure pressure 72 inch H2O p.2 ↗ 2BH1900, 60 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1900, 50 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1900, 60 Hz
Weight 169 lbs p.2 ↗ 2BH1900, 50 Hz
Weight 153 lbs p.2 ↗ 2BH1900, 60 Hz
Degree of protection IP55 p.2 ↗ 2BH1900
ATEX category 3/2G p.2 ↗ 2BH1900, Z=M71

Operating Limits

  • Max ambient/air temperature for performance curves: 59 °F p.1 ↗
  • Atmospheric pressure for performance curves: 29.92 inch Hg p.1 ↗
  • Performance tolerance: ±10 % p.1 ↗
  • Degree of protection: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series G-BH1 side channel blower
5-7 p.2 ↗ 900 Size 900
field 1 p.2 ↗ 1 Version / generation
field 2 p.2 ↗ A Motor variant
field 3 p.2 ↗ D Voltage code (D or G)
field 4 p.2 ↗ 3 Frequency code (3 = 50 Hz, 6 = 60 Hz)
field 5 p.2 ↗ 1 Voltage variant (1, 5, 6)