Technical Reference Summary
Covered Models & Document Scope
Soplador de canal lateral G-BH1, hoja de datos 2BH1 900. Abarca el tipo 2BH1900 con cuatro tamaños de prestación (n.º 1-4) y variantes de tensión: motores de amplio rango 50/60 Hz (H), 500/575 V (C) y motores de tensión alternativa/VFD (K, Q). Códigos de pedido 2BH1900-1AH07, -1AH17, -1AH27, -1AH37, -1AC03, -1AC13, -1AC23, -1AC33.
Technical Data
| Parameter |
Value |
Condition |
| Rated pressure level |
182 mbar
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Max. differential pressure vacuum |
-190 mbar
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Max. differential pressure pressure |
190 mbar
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Voltage |
345-415 D / 600-720 Y V
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Current |
18,2 D / 10,5 Y A
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Power |
8,5 kW
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Sound pressure level |
71 dB(A)
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Weight |
182 kg
p.2 ↗ |
2BH1900-1AH07, 50 Hz |
| Rated pressure level |
198 mbar
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Max. differential pressure vacuum |
-290 mbar
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Max. differential pressure pressure |
280 mbar
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Voltage |
345-415 D / 600-720 Y V
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Current |
28,0 D / 16,1 Y A
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Power |
12,5 kW
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Sound pressure level |
74 dB(A)
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Weight |
198 kg
p.2 ↗ |
2BH1900-1AH17, 50 Hz |
| Rated pressure level |
207 mbar
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Max. differential pressure vacuum |
-350 mbar
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Max. differential pressure pressure |
390 mbar
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Voltage |
345-415 D / 600-720 Y V
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Current |
32,0 D / 17,3 Y A
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Power |
15,0 kW
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Sound pressure level |
74 dB(A)
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Weight |
207 kg
p.2 ↗ |
2BH1900-1AH27, 50 Hz |
| Rated pressure level |
217 mbar
p.2 ↗ |
2BH1900-1AH37, 50 Hz |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C
p.1 ↗
- Performance curve reference air temperature: 15 °C
p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar
p.1 ↗
- Performance tolerance: ±10 %
p.1 ↗
- Protection category: IP 55
p.1 ↗
- Insulation class: F
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-6
p.2 ↗ |
2BH190 |
Series/type: side channel blower G-BH1, size 900 |
| □ (voltage field)
p.2 ↗ |
H / C / K / Q |
Motor voltage/design variant selected from alternate-voltage table |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
S'applique à |
Note |
| 2BH1900-1AH07
p.2 ↗ |
2BH1900-1AH07 |
H |
Size 1, 50/60 Hz wide-range voltage |
Order No. as printed |
| 2BH1900-1AH17
p.2 ↗ |
2BH1900-1AH17 |
H |
Size 2, 50/60 Hz wide-range voltage |
Order No. as printed |
| 2BH1900-1AH27
p.2 ↗ |
2BH1900-1AH27 |
H |
Size 3, 50/60 Hz wide-range voltage |
Order No. as printed |
| 2BH1900-1AH37
p.2 ↗ |
2BH1900-1AH37 |
H |
Size 4, 50/60 Hz wide-range voltage |
Order No. as printed |
| 2BH1900-1AC03
p.2 ↗ |
2BH1900-1AC03 |
C |
Size 1, 500/575 V |
Order No. as printed |
| 2BH1900-1AC13
p.2 ↗ |
2BH1900-1AC13 |
C |
Size 2, 500/575 V |
Order No. as printed |
| 2BH1900-1AC23
p.2 ↗ |
2BH1900-1AC23 |
C |
Size 3, 500/575 V |
Order No. as printed |
| 2BH1900-1AC33
p.2 ↗ |
2BH1900-1AC33 |
C |
Size 4, 500/575 V |
Order No. as printed |