Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — 2BH1930 HT vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 930: soplador de canal lateral con motores IE3, serie G-BH 1 N HT. Cubre el tipo 2BH1930 en los tamaños 1 y 2, 50 Hz y 60 Hz, diversas variantes de tensión (190-210 V, 220-240 V, 380-420 V, 440-480 V, 500 V, 575 V, 660-725 V, 690 V), clases de eficiencia IE3 y NP.

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH1930, 50 Hz
Voltage 190-210 D V p.2 ↗ 2BH1930-2AK11, 50 Hz
Current 35,0 D A p.2 ↗ 2BH1930-2AK11, 50 Hz
Power 9,0 kW p.2 ↗ 2BH1930-2AK11, 50 Hz
Max. differential pressure vacuum -160 mbar p.2 ↗ 2BH1930-2AK11, 50 Hz
Max. differential pressure pressure 150 mbar p.2 ↗ 2BH1930-2AK11, 50 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1930-2AK11, 50 Hz
Weight approx. 247 kg p.2 ↗ 2BH1930-2AK11, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1930-2AK11, 50 Hz
Rated frequency 60 Hz p.2 ↗ 2BH1930-2AK11, 60 Hz
Voltage 190-210 UU / 380-420 U V p.2 ↗ 2BH1930-2AK11, 60 Hz
Current 41,2 UU / 20,6 U A p.2 ↗ 2BH1930-2AK11, 60 Hz
Power 11,0 kW p.2 ↗ 2BH1930-2AK11, 60 Hz
Max. differential pressure vacuum -140 mbar p.2 ↗ 2BH1930-2AK11, 60 Hz
Max. differential pressure pressure 120 mbar p.2 ↗ 2BH1930-2AK11, 60 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1930-2AK11, 60 Hz
Weight approx. 247 kg p.2 ↗ 2BH1930-2AK11, 60 Hz
Efficiency class IE3 p.2 ↗ 2BH1930-2AK11, 60 Hz
Protection category IP55 p.2 ↗ all variants
Insulation class F p.2 ↗ all variants

Operating Limits

  • Max ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance tolerance: ± 10 % p.1 ↗
  • Protection category: IP55 p.2 ↗
  • Insulation class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH1 Series designation (side channel blower)
6-8 p.2 ↗ 930 Size / type number
9-10 p.2 ↗ 2A Variant code (motor/voltage family)

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1930-2AK11 p.2 ↗ 2BH1930-2AK11 50 Hz, 190-210 V D; 60 Hz, 190-210 V UU / 380-420 V U Size 1, IE3
2BH1930-2AK21 p.2 ↗ 2BH1930-2AK21 50 Hz, 190-210 V D; 60 Hz, 190-210 V UU / 380-420 V U Size 2, IE3
2BH1930-2AK16 p.2 ↗ 2BH1930-2AK16 50 Hz, 220-240 V D / 380-420 V U; 60 Hz, 220-240 V UU / 440-480 V U Size 1, IE3
2BH1930-2AK26 p.2 ↗ 2BH1930-2AK26 50 Hz, 220-240 V D / 380-420 V U; 60 Hz, 220-240 V UU / 440-480 V U Size 2, IE3
2BH1930-2AQ13 p.2 ↗ 2BH1930-2AQ13 50 Hz, 500 V U; 60 Hz, 575 V U Size 1, IE3
2BH1930-2AQ23 p.2 ↗ 2BH1930-2AQ23 50 Hz, 500 V U; 60 Hz, 575 V U Size 2, IE3
2BH1930-2AQ17 p.2 ↗ 2BH1930-2AQ17 50 Hz, 380-420 V D / 660-725 V U; 60 Hz, 440-480 V D Size 1, IE3
2BH1930-2AQ27 p.2 ↗ 2BH1930-2AQ27 50 Hz, 380-420 V D / 660-725 V U; 60 Hz, 440-480 V D Size 2, IE3