Technical Reference Summary
Covered Models & Document Scope
Familia de bombas de vacío de anillo líquido L-BV2, hoja de datos 2BV2 070. Abarca la 2BV2070 con motores de 50 Hz y 60 Hz, rangos de tensión 190-210, 220-240/380-420, 440-480, 500, 575, 380-420/660-725, 460 V, eficiencia IE3 o NP, y variantes de material N (fundición/cerámica/bronce), C (fundición/cerámica/acero CrNi), P (acero CrNi/cerámica/acero CrNi), H (acero CrNi/acero CrNi/acero CrNi). Bombas de categoría ATEX 2G disponibles.
Technical Data
| Parameter |
Value |
Condition |
| Operating principle |
Liquid ring vacuum pump
p.1 ↗ |
2BV2 070 |
| Ultimate inlet pressure |
33 mbar abs.
p.1 ↗ |
2BV2 070 |
| Cavitation-free operation down to |
80 mbar abs.
p.1 ↗ |
2BV2 070, with built-in cavitation protection |
| Suction capacity |
66 m³/h
p.2 ↗ |
2BV2070, 50 Hz, 2.6 kW |
| Suction capacity |
70 m³/h
p.2 ↗ |
2BV2070, 50 Hz, 3.7 kW |
| Suction capacity |
70 m³/h
p.2 ↗ |
2BV2070, 60 Hz, 3.5 kW |
| Motor power |
2,6 kW
p.2 ↗ |
2BV2070, 50 Hz |
| Motor power |
3,7 kW
p.2 ↗ |
2BV2070, 50 Hz |
| Motor power |
3,5 kW
p.2 ↗ |
2BV2070, 60 Hz |
| Voltage |
190-210 V
p.2 ↗ |
2BV2070, 50 Hz, 2.6 kW |
| Voltage |
220-240 / 380-420 V
p.2 ↗ |
2BV2070, 50 Hz, 2.6 kW |
| Voltage |
440-480 V
p.2 ↗ |
2BV2070, 60 Hz, 3.7 kW |
| Current |
16,5 A
p.2 ↗ |
2BV2070, 50 Hz, 190-210 V, 2.6 kW |
| Current |
18,6 / 9,3 A
p.2 ↗ |
2BV2070, 50 Hz, 190-210/380-420 V, 3.7 kW |
| Current |
8,1 A
p.2 ↗ |
2BV2070, 60 Hz, 440-480 V, 3.7 kW |
| Service factor |
1,54
p.2 ↗ |
2BV2070, 50 Hz, 2.6 kW |
| Service factor |
1,23
p.2 ↗ |
2BV2070, 50 Hz, 3.7 kW |
| Service factor |
1,22
p.2 ↗ |
2BV2070, 60 Hz, 3.5 kW |
| Efficiency level |
IE3
p.2 ↗ |
2BV2070, 2.6 kW and 3.7 kW |
| Noise level |
66 dB(A)
p.2 ↗ |
2BV2070, 50 Hz, 2.6 kW |
| Noise level |
70 dB(A)
p.2 ↗ |
2BV2070, 50 Hz, 3.7 kW |
| Weight |
46 kg
p.2 ↗ |
2BV2070, 2.6 kW |
| Weight |
49 kg
p.2 ↗ |
2BV2070, 3.7 kW |
| Protection rating |
IP55
p.2 ↗ |
2BV2070 |
| Insulation class |
F
p.2 ↗ |
2BV2070 |
Operating Limits
- Minimum inlet pressure (ultimate vacuum): 33 mbar abs.
p.1 ↗
- Cavitation-free operation minimum inlet pressure: 80 mbar abs.
p.1 ↗
- Maximum additional water carry-over: 0,70 m³/h at 50 Hz; 0,85 m³/h at 60 Hz
p.2 ↗
- Maximum back pressure: 1200 mbar abs.
p.2 ↗
- Protection rating: IP55
p.2 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-4
p.2 ↗ |
2BV2 |
Product family: liquid ring vacuum pump L-BV2 |
| 5-7
p.2 ↗ |
070 |
Size 070 |
| field 1 (after 2BV2…-)
p.2 ↗ |
0 |
Design variant / generation |
| field 2 (material code)
p.2 ↗ |
N, C, P, H |
Material variant: N = cast iron casing with ceramic coating / bronze port plate; C = cast iron casing with ceramic coating / CrNi steel port plate; P = CrNi steel casing / ceramic port plate / CrNi steel impeller; H = CrNi steel casing / Cr |
| field 3 (voltage/frequency code)
p.2 ↗ |
K, Q |
Voltage/frequency variant: K = 50 Hz 190-210 V or 220-240/380-420 V; Q = 60 Hz 440-480 V or 50 Hz 380-420/660-725 V |
| field 4 (suffix)
p.2 ↗ |
1, 6, 7 |
Ordering suffix: 1 = 2.6 kW variant; 6 = 3.7 kW variant; 7 = 3.7 kW variant with 60 Hz 440-480 V |