Operating Instructions — BA 892-DE (BA 892-DE, ed. 1.1 18.02.2025, DE)

Technical Reference Summary

Covered Models & Document Scope

This operating manual (BA 892-DE, edition 1.1, 18.02.2025) covers the contact-free running claw vacuum pump C-VLU 301, including the standard version and the corrosion-protected variant 'XD' suitable for water-vapour-laden gases. It addresses the complete machine (pump + flanged three-phase standard motor) and optional accessories such as the intake filter and plug connection.

Section-by-Section Technical Breakdown

pp. 14-16
Product overview and function

The C-VLU 301 is a two-shaft rotary claw vacuum pump with contact-free, dry-running claw rotors synchronised by a gear pair. Bearings and gears are oil-lubricated in a separate gearbox; the compression chamber is sealed by piston rings. An integrated check valve prevents venting of the evacuated system after shutdown, and a sound-insulating hood with drum fan provides cooling.

  • Two-shaft rotary claw principle, contact-free and dry running
  • Gear pair synchronises the counter-rotating claw rotors
  • Gearbox oil supply for bearings and gears; compression chamber separated by special seals
  • Integrated check valve prevents venting of the evacuated system after shutdown
  • Sound-insulating hood with drum fan draws cooling air between compressor and hood
  • Drive via coupling from a flanged three-phase standard motor
pp. 15
Nameplate and identification

The nameplate carries type/size, serial number, year of construction, Data Matrix barcode, article number, speed, motor power, operating mode, pumping speed and ultimate pressure for 50 Hz and 60 Hz. The barcode encodes material number (MA), production order (PR) and serial number (SC).

  • Nameplate fields 1-10: type/size, serial number, year, Data Matrix barcode, article number, speed 50/60 Hz, motor power 50/60 Hz, operating mode, pumping speed 50/60 Hz, ultimate pressure 50/60 Hz
  • Example nameplate: C-VLU 301 CD (01), 30.00/30.00 mbar (abs), 265.0/320.0 m³/h, 7.50/9.00 kW, 2935/3530 /min, S1 100%
  • Barcode encodes material number (MA), production order (PR) and serial number (SC)
  • Nameplates must not be removed, even on resale; always quote the serial number for enquiries
pp. 16
Areas of application

The pump may be operated continuously at any pressure between 700 mbar (abs.) and an intake pressure of 30 mbar (abs.). Pumping speed at free intake is 265 m³/h at 50 Hz; the dependence on intake pressure is shown in data sheet D 892. The 'XD' variant has a corrosion-protection coating and is suitable for conveying water-moist gases (water vapour).

  • Continuous operation permitted between 700 mbar (abs.) and 30 mbar (abs.) intake pressure
  • Pumping speed at free intake: 265 m³/h at 50 Hz
  • Variant 'XD': corrosion-protection coating, suitable for water-moist gases (water vapour)
  • At increased switching frequency (approx. 10 times per hour at regular intervals) or elevated ambient/intake temperature, the motor winding and bearing limit temperature may be exceeded — consult manufacturer
  • Outdoor installation requires protection from environmental influences (e.g. protective roof)
  • Minimum permissible ultimate pressure is stated on the nameplate
pp. 17-18
Installation and siting

The machine must be installed horizontally (max. 8° inclination in all directions) on a level, flat surface with sufficient load-bearing capacity. At least 50 cm clearance around the machine is required for maintenance, and cooling-air inlet/outlet must be at least 30 cm from adjacent walls. Ambient temperature must be between +5 °C and +40 °C.

  • Horizontal installation only, max. 8° inclination in all directions
  • Minimum 50 cm clearance around the machine for maintenance work
  • Cooling-air inlet and outlet at least 30 cm from adjacent walls; exhaust cooling air must not be re-aspirated
  • Ambient temperature min. +5 °C, max. +40 °C
  • Machine must be freely accessible from all sides; ventilation grilles must not be covered
  • No external vibrations; do not draw hot exhaust air from other machines for cooling
  • Oil fill point, oil sight glass and oil drain must remain easily accessible
  • Installation above 1000 m above sea level causes noticeable performance reduction — consult manufacturer
  • Installation on solid ground possible without anchoring; on a substructure, elastic buffer elements are recommended
pp. 18
Pipework connection

The vacuum connection is on the suction flange and the discharge is via the exhaust silencer. The exhaust opening must not be closed or restricted; no shut-off devices may be installed, and the maximum permissible back pressure is +30 mbar. Pipes must be screwed in by hand only, and flexible connections/compensators are recommended to avoid stress.

  • Maximum permissible back pressure: +30 mbar
  • Exhaust opening must not be closed, restricted or covered; no shut-off devices in the exhaust line
  • Remove blind plug/adhesive film at vacuum connection and exhaust outlet before connecting
  • Screw pipes in by hand only; use flexible connections/compensators to avoid stress
  • Avoid liquid accumulation in the exhaust line; check connected exhaust lines regularly for contamination
  • Too narrow and/or too long suction line reduces pumping speed
pp. 19
Electrical connection

Electrical installation must be performed by a qualified electrician in accordance with EN 60204. The operator must provide a main switch and a motor protection switch. Motors comply with DIN EN 60034, protection class IP 55 and insulation class F; permissible tolerances are ±5 % voltage and ±2 % frequency.

  • Electrical installation only by qualified electrician according to EN 60204
  • Main switch and motor protection switch must be provided by the operator
  • Motors: DIN EN 60034, IP 55, insulation class F
  • Permissible voltage deviation ±5 % of nominal value; frequency deviation ±2 %
  • Single-phase motors >1.7 kVA, three-phase motors >5.2 kVA, or motors with starting currents >60 A are not designed for direct-on-line starting
  • For high starting torques use star-delta starting, soft starter or frequency converter
  • Motor protection switch with delayed tripping recommended to allow for short-term overcurrent during cold start
  • Cable gland required for strain relief
pp. 22-23
Commissioning

Before commissioning, an installation check must confirm no transport/mounting damage, secure horizontal positioning, correct and tight pipe connections, tight screw/flange connections, correct electrical installation, adequate room ventilation, oil filled and oil level checked, and cleaned pump and pipes. Direction of rotation must be checked with a phase-sequence indicator; the motor fan must rotate counter-clockwise when viewed from the fan.

  • Installation check list: no damage, secure horizontal position, correct pipe connections and tightness, tight screw/flange connections, correct electrical installation, adequate ventilation, oil filled and level checked, pump and pipes cleaned, optional accessories functional
  • Check direction of rotation with a phase-sequence indicator (clockwise phase sequence)
  • Briefly start motor for direction check (max. two seconds); viewed from the motor fan, it must rotate counter-clockwise
  • Keep 1 m distance from pressure and suction connections during direction check
  • Prolonged reverse running can cause injury by suction and damage to the machine
pp. 23-24
Operation and condensate drain

For variant XD, condensate must be drained regularly from the silencer depending on application; do not drain by hand and wear protective gloves. Before shutdown for more than 2 hours, the pump should run on with dry air at 500 mbar (abs.) for at least 15–30 minutes to remove moisture and contamination.

  • Variant XD: drain condensate regularly from the silencer at the condensate drain
  • Do not drain condensate by hand; allow machine to cool before draining and wear protective gloves
  • Before standstill >2 hours or decommissioning, run pump with dry air at 500 mbar (abs.) for at least 15–30 minutes
  • Depending on application, running on with purge gas is recommended — consult manufacturer
  • Condensate and contamination can cause deposits on rotors and compressor housing and prevent restart
pp. 24
Decommissioning and restart

Decommissioning requires disconnecting the machine from the power supply and securing against reconnection, letting it run on with dry air, cooling down, closing shut-off devices if present, depressurising, removing pipes/hoses, draining condensate (XD) and sealing connections with adhesive film. Restart requires checking machine condition and repeating installation and commissioning steps.

  • Disconnect from power supply and secure against reconnection
  • Let pump run on with dry air before shutdown (see chapter 6.2.1)
  • Switch off and allow to cool; surface temperatures can exceed 70 °C when hot
  • Close shut-off devices in suction and pressure lines if present
  • Depressurise by slowly opening pipes
  • Remove pipes and hoses; drain condensate from silencer (XD); seal suction and pressure connections with adhesive film
  • For recommissioning, check machine condition (cleanliness, wiring, etc.) and repeat installation and commissioning steps
pp. 25-26
Maintenance

Regular maintenance is required to ensure operational safety. Maintenance intervals depend on load, operating conditions and oil type; extreme temperatures or contamination can shorten oil life to as little as 5,000 operating hours, while the stated 20,000-hour interval applies only to oils supplied or approved by Elmo Rietschle. A general overhaul is due at 40,000 hours.

  • At least monthly: check pipework and fittings for leaks and tightness; check terminal box and cable entries for leaks; clean ventilation slots and motor cooling fins; check oil level; check/clean/replace air filter
  • Depending on contamination: clean vacuum pump
  • Depending on condensate formation: drain condensate from silencer (XD)
  • Oil change: up to 20,000 h only with Elmo Rietschle-supplied or approved oils; extreme load can shorten oil life to as little as 5,000 h
  • At least annually: check coupling wear
  • Motor maintenance according to manufacturer's instructions
  • 40,000 h: general overhaul of vacuum pump (replacement of wear and sealing parts) by Elmo Rietschle Service
  • Before maintenance: disconnect electrically and secure against reconnection; vent pump to atmosphere; allow to cool (except oil change, where warm oil drains better); post 'Attention Maintenance Work!' sign
pp. 26, 30
Cleaning and filters

The vacuum pump must be checked regularly for dust deposits and cleaned as required. The intake filter (accessory) protects the machine from dust and solids; its filter cartridge must be cleaned monthly (more often if heavily contaminated) by blowing from inside to outside, and replaced every six months.

  • Clean pump with damp cloth or by vacuuming; remove dust from pump housing, between motor cooling fins, at silencer and piping, and at accessories
  • Intake filter cartridge: clean monthly by blowing from inside to outside; replace every six months
  • Intake filter available with paper or polyester filter element
  • To service intake filter: switch off, secure against reconnection, vent to atmospheric pressure, release clamps, remove and clean/replace cartridge, refit and secure
pp. 30-31
Motor and coupling

Motor maintenance must follow the motor manufacturer's operating and maintenance instructions. The coupling ring gear is subject to wear and must be checked at least once a year; frequent starting and high ambient temperature shorten its life. Motor flange screws are tightened to 84 Nm.

  • Coupling ring gear must be checked for wear at least once a year
  • Frequent starting and high ambient temperature shorten coupling ring gear life
  • Defective ring gear can cause rotor shaft breakage and machine failure
  • Motor flange screw tightening torque: 84 Nm
  • Ventilator should be checked periodically for damage
pp. 32
Spare parts and oils

Only original spare parts or manufacturer-approved parts may be used. Spare parts are listed in spare parts list E 892; service kits containing wear parts and seals are available. Approved oils are GEAR LUBE 150 and ECO GEAR LUBE 150, both with 20,000 h change interval.

  • Spare parts: coupling star ZS1178582, sieve filter 5290700000, filter cartridge 7320770000
  • GEAR LUBE 150: 20,000 h, 1 l can (7201706000), 200 l drum (7201656000), synthetic oil with high ageing resistance and wear protection
  • ECO GEAR LUBE 150: 20,000 h, 1 l can (7203850000), synthetic oil for food and pharmaceutical industry, FDA 21 CFR 178.3570 and USDA H-1, Halal and Kosher certified
  • Use only original spare parts or manufacturer-approved parts; otherwise liability/warranty is void
pp. 15, 35
Technical data

Technical data are given in chapter 10 and on the nameplate. Key values from the nameplate example: pumping speed 265.0/320.0 m³/h at 50/60 Hz, ultimate pressure 30.00/30.00 mbar (abs), motor power 7.50/9.00 kW, speed 2935/3530 rpm, operating mode S1 100%.

  • Pumping speed: 265.0 m³/h at 50 Hz, 320.0 m³/h at 60 Hz
  • Ultimate pressure (abs.): 30.00 mbar at 50 Hz and 60 Hz
  • Motor power: 7.50 kW at 50 Hz, 9.00 kW at 60 Hz
  • Speed: 2935 rpm at 50 Hz, 3530 rpm at 60 Hz
  • Operating mode: S1 100%
  • Refer to chapter 10 and data sheet D 892 for complete technical data and curves

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication S'applique à
Continuous operation permitted at any pressure between 700 mbar (abs.) and 30 mbar (abs.) intake pressure. p.16 ↗ Select the pump only for applications whose working vacuum lies within this range; operation outside may damage the pump. C-VLU 301
Pumping speed at free intake is 265 m³/h at 50 Hz; nameplate example shows 265.0/320.0 m³/h at 50/60 Hz. p.16 ↗ Use these values for sizing; actual pumping speed depends on intake pressure (see data sheet D 892). C-VLU 301
Maximum permissible back pressure is +30 mbar. p.18 ↗ Exhaust line must be sized and routed to keep back pressure below +30 mbar; no shut-off devices may be installed in the exhaust line. C-VLU 301
Ambient temperature must be between +5 °C and +40 °C. p.17 ↗ Ensure installation room ventilation and cooling-air supply keep ambient temperature within this range. C-VLU 301
Machine must be installed horizontally with max. 8° inclination in all directions. p.17 ↗ Mount on a level, flat, load-bearing surface; secure against tipping and falling. C-VLU 301
Cooling-air inlet and outlet must be at least 30 cm from adjacent walls; minimum 50 cm clearance around the machine for maintenance. p.17 ↗ Plan installation layout to provide these clearances and prevent re-aspiration of exhaust cooling air. C-VLU 301
Permissible voltage deviation ±5 % of nominal value; frequency deviation ±2 %. p.19 ↗ Verify site power quality before connection; out-of-tolerance supply can reduce performance or damage the motor. C-VLU 301
Motors are IP 55, insulation class F, compliant with DIN EN 60034. p.19 ↗ Suitable for dusty/wet industrial environments within the stated ambient limits; electrical installation per EN 60204. C-VLU 301
Single-phase motors >1.7 kVA, three-phase motors >5.2 kVA, or motors with starting currents >60 A are not designed for direct-on-line starting. p.19 ↗ Use star-delta starting, soft starter or frequency converter for such motors to limit starting current and mechanical load. C-VLU 301
Motor flange screw tightening torque: 84 Nm. p.31 ↗ Tighten coupling/motor flange screws to 84 Nm when refitting the motor after coupling inspection. C-VLU 301
Oil change interval up to 20,000 operating hours applies only to oils supplied or approved by Elmo Rietschle; extreme temperatures or contamination can shorten oil life to as little as 5,000 operating hours. p.25 ↗ Use only approved oils (GEAR LUBE 150 or ECO GEAR LUBE 150) and adjust oil change interval according to actual operating conditions. C-VLU 301
General overhaul of the vacuum pump (replacement of wear and sealing parts) is due at 40,000 operating hours. p.26 ↗ Plan service by Elmo Rietschle Service at 40,000 h to maintain reliability. C-VLU 301
Before standstill of more than 2 hours or before decommissioning, run the pump with dry air at 500 mbar (abs.) for at least 15–30 minutes. p.24 ↗ This removes moisture and contamination and prevents deposits that could block restart. C-VLU 301
Coupling ring gear must be checked for wear at least once a year. p.30 ↗ Regular inspection prevents rotor shaft breakage and machine failure caused by a defective ring gear. C-VLU 301
Intake filter cartridge must be cleaned monthly (more often if heavily contaminated) and replaced every six months. p.30 ↗ Maintain intake filter to protect the machine from dust and solids and to avoid reduced pumping speed. C-VLU 301 with optional intake filter
Variant 'XD' has a corrosion-protection coating and is suitable for conveying water-moist gases (water vapour). p.16 ↗ Select the XD variant for applications with water vapour; drain condensate regularly from the silencer. C-VLU 301 XD
At increased switching frequency (approx. 10 times per hour at regular intervals) or elevated ambient/intake temperature, the motor winding and bearing limit temperature may be exceeded. p.16 ↗ Consult the manufacturer for such duty; standard motor may not be suitable without derating or additional measures. C-VLU 301
Installation above 1000 m above sea level causes noticeable performance reduction. p.18 ↗ Consult manufacturer for installations at altitude to account for reduced cooling and performance. C-VLU 301
Surface temperatures can exceed 70 °C during operation. p.24 ↗ Provide touch protection or keep hot parts inaccessible; wear protective gloves during maintenance. C-VLU 301
The vacuum pump has no built-in emergency stop or emergency off; this must be provided by the operator, e.g. by integrating the pump into the operator's safety concept. p.11 ↗ Design the system-level safety circuit to include emergency stop for the pump. C-VLU 301

Faults & Troubleshooting

Code / Symptôme Possible Cause Remedy Note
Maschine wird durch Motorschutzschalter abgeschaltet p.33 ↗ Netzspannung/ Frequenz stimmt nicht mit den Motordaten überein Überprüfung durch Elektrofachkraft Kapitel 5.5
Maschine wird durch Motorschutzschalter abgeschaltet p.33 ↗ Anschluss am Motorklemmbrett ist nicht korrekt Überprüfung durch Elektrofachkraft Kapitel 5.5
Maschine wird durch Motorschutzschalter abgeschaltet p.33 ↗ Motorschutzschalter ist nicht korrekt eingestellt Überprüfung durch Elektrofachkraft Kapitel 5.5
Motorschutzschalter löst zu rasch aus p.33 ↗ Kurzzeitiger Überstrom beim Kaltstart der Maschine Verwendung eines Motorschutzschalters mit überlastabhängiger Abschaltverzögerung, die den kurzzeitigen Überstrom beim Start berücksichtigt (Ausführung mit Kurzschluss- und Überlastauslöser nach VDE 0660 Teil 102 bzw. IEC/EN 60947-4-1)
Saugleistung ist ungenügend p.33 ↗ Luftfilter ist verschmutzt Luftfilter reinigen / erneuern Kapitel 7.6, Kapitel 7.9
Saugleistung ist ungenügend p.33 ↗ Saugleitung ist zu lang oder zu eng Schlauch- bzw. Rohrleitung überprüfen Kapitel 5.3
Saugleistung ist ungenügend p.33 ↗ Undichtigkeit an der Maschine oder im System Verrohrung und Verschraubungen auf Undichtigkeiten und festen Sitz prüfen Kapitel 5.3
Enddruck (max. Vakuum) wird nicht erreicht p.33 ↗ Undichtigkeit an der Maschine oder im System Verrohrung und Verschraubungen auf Undichtigkeiten und festen Sitz prüfen Kapitel 5.3
Enddruck (max. Vakuum) wird nicht erreicht p.33 ↗ Luftfilter ist verschmutzt Luftfilter reinigen / erneuern Kapitel 7.6, Kapitel 7.9
Maschine wird zu heiß p.33 ↗ Umgebungs- oder Ansaugtemperatur ist zu hoch Bestimmungsgemäße Verwendung beachten Kapitel 2.4
Maschine wird zu heiß p.33 ↗ Kühlluftstrom wird behindert Umgebungsbedingungen prüfen; Lüftungsschlitze reinigen Kapitel 5.1, Kapitel 7.4
Maschine erzeugt abnormales Geräusch p.33 ↗ Ablagerungen auf den Drehkolben Arbeitsraum und die Drehkolben reinigen Elmo Rietschle Service