Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH1 BH1035-6 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos BH1035-6 (2BH1630), soplador de canal lateral con motor monofásico, 50/60 Hz, IP55, clase de aislamiento F, aprobado UL/CSA. Códigos de pedido BH1035-6AAA-JV5-BA0 y BH1035-6AAA-JV4-BA0; variantes de motor de tensión alternativa V4 y V5.

Technical Data

Parameter Value Condition
Rated voltage 115 / 230 V p.2 ↗ BH1035-6, 50 Hz
Current 28,0 / 14,5 A p.2 ↗ BH1035-6, 50 Hz
Power 3,0 hp p.2 ↗ BH1035-6, 50 Hz
Max. differential pressure, vacuum -48 inch H2O p.2 ↗ BH1035-6, 50 Hz
Max. differential pressure, pressure 40 inch H2O p.2 ↗ BH1035-6, 50 Hz
Sound pressure level 64 dB(A) p.2 ↗ BH1035-6, 50 Hz
Weight approx. 82 lbs p.2 ↗ BH1035-6, 50 Hz
Rated voltage 115 / 230 V p.2 ↗ BH1035-6, 60 Hz
Current 27,0 / 14,3 A p.2 ↗ BH1035-6, 60 Hz
Power 3,4 hp p.2 ↗ BH1035-6, 60 Hz
Max. differential pressure, vacuum -40 inch H2O p.2 ↗ BH1035-6, 60 Hz
Max. differential pressure, pressure 36 inch H2O p.2 ↗ BH1035-6, 60 Hz
Sound pressure level 70 dB(A) p.2 ↗ BH1035-6, 60 Hz
Weight approx. 82 lbs p.2 ↗ BH1035-6, 60 Hz
Protection category IP55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Protection category: IP55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Single-phase voltage tolerance: ± 5 % p.2 ↗
  • Frequency tolerance: ± 2 % maximum p.2 ↗

Type Code Decoder

Position Token Meaning
1-9 p.2 ↗ BH1035-6 Type / size designation (2BH1630)
10-12 p.2 ↗ AAA Motor / design variant field
14-16 p.2 ↗ JV5 Voltage variant: V5 = 115/230 V at 50 Hz and 60 Hz
14-16 p.2 ↗ JV4 Voltage variant: V4 = 100/200 V at 50 Hz and 60 Hz
18-20 p.2 ↗ BA0 Configuration suffix

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
BH1035-6AAA-JV5-BA0 p.2 ↗ BH1035-6AAA-JV5-BA0 V5 1~ 50/60 Hz, 115/230 V Order No. as printed
BH1035-6AAA-JV4-BA0 p.2 ↗ BH1035-6AAA-JV4-BA0 V4 1~ 50/60 Hz, 100/200 V Order No. as printed; electrical data #NV