Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — VSI 300 vacuum pump (US)

Technical Reference Summary

Covered Models & Document Scope

S-VSI 300 (44) bomba de vacío de tornillo sin contacto, en seco; variantes de 50 Hz y 60 Hz

Technical Data

Parameter Value Condition
Suction capacity maximum 188 cfm p.1 ↗ S-VSI 300 (44), 50 Hz
Suction capacity maximum 224 cfm p.1 ↗ S-VSI 300 (44), 60 Hz
Ultimate vacuum 0.075 Torr p.1 ↗ S-VSI 300 (44)
Ultimate vacuum 29.92 in. HgV p.1 ↗ S-VSI 300 (44)
Rated voltage 400 / 690 V p.1 ↗ S-VSI 300 (44), 50 Hz, 3~, ± 10 %
Rated voltage 208 - 230 / 460 V p.1 ↗ S-VSI 300 (44), 60 Hz, 3~, ± 10 %
Motor rating 5.5 kW p.1 ↗ S-VSI 300 (44), 50 Hz
Motor rating 7.5 kW p.1 ↗ S-VSI 300 (44), 60 Hz
Motor rating 7.5 hp p.1 ↗ S-VSI 300 (44), 50 Hz
Motor rating 10 hp p.1 ↗ S-VSI 300 (44), 60 Hz
Full load amperage 10,1 / 5,8 A p.1 ↗ S-VSI 300 (44), 50 Hz
Full load amperage 13,8 / 8,0 A p.1 ↗ S-VSI 300 (44), 60 Hz
Full load amperage 21 - 18.8 / 9.4 A p.1 ↗ S-VSI 300 (44), 60 Hz
Full load amperage 25 - 24 / 12 A p.1 ↗ S-VSI 300 (44), 60 Hz
Speed 2900 rpm p.1 ↗ S-VSI 300 (44), 50 Hz
Speed 3550 rpm p.1 ↗ S-VSI 300 (44), 60 Hz
Average noise level 74 dB(A) p.1 ↗ S-VSI 300 (44), 50 Hz, EN ISO 3744
Average noise level 76 dB(A) p.1 ↗ S-VSI 300 (44), 60 Hz, EN ISO 3744
Weight maximum 701 lbs p.1 ↗ S-VSI 300 (44), 50 Hz
Weight maximum 723 lbs p.1 ↗ S-VSI 300 (44), 60 Hz
Weight maximum 695 lbs p.1 ↗ S-VSI 300 (44), 50 Hz
Weight maximum 715 lbs p.1 ↗ S-VSI 300 (44), 60 Hz
Oil capacity 1.9 (1.1 ➝ H + 0.8 ➝ H1) qt p.1 ↗ S-VSI 300 (44)
Cooling water consumption 6.7 l / min p.1 ↗ S-VSI 300 (44)
Max intake temperature 50 °C p.2 ↗ S-VSI 300 (44)

Operating Limits

  • Max intake temperature: 50 °C p.2 ↗