Technical Data Sheet — C-VLR 1000 vacuum pump (US)
Technical Reference Summary
Covered Models & Document Scope
Bomba de vacío de garra seca sin contacto C-VLR 1000 con motor NEMA Premium; variantes de 50 Hz y 60 Hz; accesorios ZRZ 100, ZVF 100, ZMS (bajo pedido)
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Suction capacity | 559 cfm p.1 ↗ | C-VLR 1000, 50 Hz |
| Suction capacity | 671 cfm p.1 ↗ | C-VLR 1000, 60 Hz |
| Ultimate vacuum continuous operation | 150 Torr - 24.0 in. HgV p.1 ↗ | C-VLR 1000 |
| Rated voltage | 400 / 690 V ± 10 % p.1 ↗ | C-VLR 1000, 3~, 50 Hz |
| Rated voltage | 208 - 230 / 460 V ± 10 % p.1 ↗ | C-VLR 1000, 3~, 60 Hz |
| Motor rating | 18.5 kW p.1 ↗ | C-VLR 1000, 50 Hz |
| Motor rating | 30 hp p.1 ↗ | C-VLR 1000, 60 Hz |
| Full load amperage | 34.0 / 19.7 A p.1 ↗ | C-VLR 1000, 50 Hz |
| Full load amperage | 74.8 - 67.6 / 33.8 A p.1 ↗ | C-VLR 1000, 60 Hz |
| Speed | 2940 rpm p.1 ↗ | C-VLR 1000, 50 Hz |
| Speed | 3530 rpm p.1 ↗ | C-VLR 1000, 60 Hz |
| Average noise level | 82 dB(A) p.1 ↗ | C-VLR 1000, 50 Hz, EN ISO 3744 |
| Average noise level | 83 dB(A) p.1 ↗ | C-VLR 1000, 60 Hz, EN ISO 3744 |
| Weight | 1669 lbs p.1 ↗ | C-VLR 1000, 50 Hz |
| Weight | 1803 lbs p.1 ↗ | C-VLR 1000, 60 Hz |
| Oil capacity (gear) | 2.8 qt p.1 ↗ | C-VLR 1000 |
Operating Limits
- Ultimate vacuum continuous operation: 150 Torr - 24.0 in. HgV p.1 ↗
- Rated voltage tolerance: ± 10 % p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.1 ↗ | C-VLR | Product series: dry contactless claw vacuum pump |
| 7-10 p.1 ↗ | 1000 | Size designation |