Agilent Technologies Turbo V 81
Agilent Technologies Turbo V 81 — Pompes à vide turbomoléculaires con Puissance du moteur 0.05 kW, Niveau sonore 45 dB, Vitesse de pompage 7.2 m³/h.
The Turbo-V 81-T is a turbomolecular pump with a 9-stage aluminium turbine on permanently lubricated ceramic ball bearings, driven by a 54 Vac three-phase motor at up to 1350 Hz. It reaches 5×10⁻⁹ mbar base pressure with a recommended DS 42 forepump and delivers 50 l/s N₂ through its 63 mm inlet. Four flange variants (ISO 63, KF 40, CF 4.5", CF 2.75") cover clean high-vacuum duties.
Remplacements directs (drop-in)
Spécifications complètes
| Puissance du moteur | 50 W |
| Niveau sonore | 45 dB |
| Vitesse de pompage | 2 l/s |
| Pression de base | 5 mbar |
| Pression de base avec pompe primaire recommandée | 5 mbar |
| Taux de compression | 2 dimensionless |
| Pression maximale | 2 pressure |
| Vitesse de pompage H2 | 50 l/s |
| Vitesse de pompage He | 65 l/s |
| Vitesse de pompage N2 | 77 l/s |
| Vitesse de rotation | 1350 Hz |
| Temps de montée en régime | 60 seconds |
| Operating position mfr | any any |
| Input mfr | 60 max |
| Lubricant mfr | permanent lubrication lubrication |
| Installation category mfr | II II |
| Compliance with: mfr | 292 |
| Heater band 220 V mfr | 9699801 |
| Heater band 120 V mfr | 9699802 |
| Pump extension cable mfr | 9699942 |
| Vibration damper CFF 4.5" mfr | 9699376 |
| Mechanical pump DS 102 mfr | 9499315 |
| Mechanical pump DS 42 mfr | 9499309 |
| Dry scroll SH 100 mfr | 01001 UNIV |
| Dry scroll SH 110 mfr | 01101 UNIV |
| PCB 24 V mfr | 9699538 |
| Poids | 1.83 kg |
| Weight kg (lbs): mfr | 63 |
| Bride d'admission | 63 O.D. |
| Foreline flange mfr | 16 NW |
| Inlet screen, DN 40 mfr | 9699309 |
| Inlet screen, DN 63 mfr | 9699300 |
| Vibration damper DN 63 mfr | 9699375 |
| Rack controller 81-AG base mfr | 9698988 |
| Rack controller 81-AG RS232/485 mfr | 9698989 |
| Rack controller 81-AG Profibus mfr | 9698990 |
| Turbo-V 81-AG Navigator Controller 24 Vdc mfr | 9698995 |
| Turbo-V 81-AG Navigator Controller 100-240 Vac mfr | 9698996 |
| Turbo-V 81-AG Navigator Controller (cable 0.7 m) (any version) mfr | 9699844 |
| Turbo-V 81-AG Rack Controller (cable 0.7 m) (any version) mfr | 9699844 |
| Controller TV70 Navigator (P/N 9698970, 9698971) mfr | 9699834 |
| Turbo-V 70 Rack controller (P/N 9699405, 9699505) mfr | 9699843 |
| Coolant water flow mfr | 10 l/h |
| Coolant water pressure mfr | 2...4 bar |
| Coolant water mfr | 2...4 bar |
| Température de dégazage | 120 °C |
| Niveau sonore | 45 dB |
| Température de stockage | -20 °C |
| Cooling requirements mfr | Natural air convection Forced air or water optio |
| Pollution degree mfr | 2 |
| Metallic water cooling kit mfr | 9699823 |
| Plastic water cooling kit mfr | 9699824 |
| Air cooling kit (0.5 m cable) mfr | 9699290 |
| Air cooling kit extension cable (5 m) mfr | 9699940 |
| Pumping speed With ISO 63 or CFF 4.5” mfr | 2 l/s |
| ISO 63 mfr | 10 clamps |
| Fixing torque for ISO 63 flange mfr | 22 Nm |
Description
Construction and series positioning
- Single aluminium-alloy turbine block, 9 bladed stages with blade angles from 40° to 12°, supported by permanently lubricated ceramic ball bearings on the forevacuum side.
- The series comprises four versions that differ only in the high-vacuum flange: Model 9698905 (ISO 63), 9698906 (KF 40 NW), 9698907 (ConFlat 4.5" O.D.) and 9698908 (ConFlat 2.75" O.D.). The 63 mm inlet and 50 l/s N₂ figure apply to the ISO 63 version; other flange variants carry their own pumping-speed data in the technical table.
- Foreline flange is KF 16 NW throughout; the pump is free of contaminating agents and intended for non-corrosive gases only — no liquids or solid particles.
Performance behaviour
- Pumping speeds: 50 l/s N₂, 56 l/s He, 46 l/s H₂. Compression ratios are modest (7 N₂, 5 He, 3 H₂), so the forepump does the bulk of the compression; base pressure of 5×10⁻⁹ mbar is specified with the recommended DS 42 mechanical forepump.
- Run-up to full speed takes less than 60 seconds; maximum rotational speed is 1350 Hz (≈80 000 rpm). Noise is ≤45 dB(A) at 1 m.
- The pump may be baked for better limit pressure: inlet flange temperature must not exceed 120 °C for ConFlat and 80 °C for ISO flanges, and water cooling must always be used while heating.
Installation, control and operation
- The pump can be mounted in any position but must be fixed via its inlet flange to a counter-flange able to withstand 250 Nm around its axis; it cannot be supported by its base. ISO 63 uses 4 M10 clamps at 22 Nm.
- Electrical connection is a 6-pin connector to an Agilent controller: pins B, C, D carry the 3-phase motor supply, pin E is pump ground, pins A and F are reserved. Direct mains connection is not permitted; the motor is rated 54 Vac three-phase, 1350 Hz max, 50 W max input.
- A thermistor near the upper bearing prevents overheating: if the temperature sensor is disconnected the pump will not start, and the sensor cuts out power above 60 °C.
- Venting must use air or inert gas free of dust and particles at less than 2 bar above atmospheric. In the presence of magnetic fields the pump must be protected with a ferromagnetic shield.
Integration & Operating Notes
The pump is fixed exclusively through its inlet flange, and the chamber flange plus support structure must be designed for 250 Nm around the axis. Supporting the pump by its base is not permitted, so the chamber interface carries the full cantilever load.
The 6-pin controller connector carries the motor phases on pins B, C, D and ground on pin E; pins A and F are reserved for Agilent. The thermistor circuit must be continuous at commissioning, because an open sensor prevents start-up and the same circuit cuts power above 60 °C.
Heater bands 9699801/9699802 heat the casing to about 80 °C, but bakeout is permitted only when inlet pressure is below 10⁻⁴ mbar and water cooling is running. Inlet flange temperature must stay within 120 °C (ConFlat) or 80 °C (ISO), otherwise flange and pump damage can result.
Coolant must be +15 °C to +35 °C at 2–4 bar inlet pressure with 10 l/h flow and conductance ≤500 µs/cm; closed circuits above that conductance should use up to 20 % Ethyl-Glycole. Natural convection limits ambient to +5…+25 °C; forced air or water extends it to +35 °C.
The Turbo-V 81-T requires no user maintenance and any work must be performed by authorized personnel. Before any intervention, disconnect mains, vent the pump, wait for rotor stop and surface temperature below 50 °C. A reconditioned replacement is available through Agilent service.
The KF 16 NW foreline may be connected by hose or vacuum-approved pipe; if a rigid pipe is used, bellows must eliminate vibration from the mechanical forepump. A suitable trap is advisable with oil-sealed forepumps to prevent oil backstreaming into the turbopump.
Selection & Integration Q&A
Pick the ISO 63 model (9698905) for 63 mm O.D. clamp-type high-vacuum connections with 4 M10 clamps at 22 Nm; choose KF 40 (9698906) for small elastomer-sealed foreline-style ports, or ConFlat 4.5"/2.75" (9698907/9698908) where metal-sealed UHV joints and 120 °C bakeout are required. Pumping-speed data differ per flange variant.
No direct mains connection: the 6-pin connector supplies a 54 Vac three-phase motor (1350 Hz max, 50 W max) and must be driven by an Agilent Navigator or Standard Rack controller. Recommended forepumps are Agilent DS 42–DS 102 mechanical pumps or the SH 100 dry pump; the 5×10⁻⁹ mbar base pressure is specified with that forepump.
Mount in any position but fix only via the inlet flange to a counter-flange rated for 250 Nm; the base cannot carry the pump. Natural convection allows +5…+25 °C ambient; above 25 °C add the 24 Vdc air cooling kit or water cooling (+5…+35 °C). Protect with a ferromagnetic shield in magnetic fields and keep vent pressure below 2 bar above atmospheric.
The pump needs no field maintenance; service is by Agilent authorized personnel, with a reconditioned replacement available. Not included: inlet screens 9699300/9699309 (≈10 % speed loss), heater bands 9699801/9699802, air cooling kit 9699290, water cooling kits 9699823/9699824, vent valves with their own control units, vibration isolators 9699375/9699376, and the controller and forepump.