Technical Data Sheet — G-BH1 2BH1800 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Ficha técnica del soplador de canal lateral G-BH1 2BH1 800; abarca el tamaño 2BH1800 con las variantes 2BH1800-1AH07, -1AH17, -1AH27 (345-415 Δ / 600-720 Y, 50 Hz; 380-480 Δ / 660-720 Y, 60 Hz), 2BH1800-1AC03, -1AC13, -1AC23 (500 Y, 50 Hz; 575 Y, 60 Hz), además de variantes de motor con tensión alternativa seleccionadas mediante el código 2BH1800-..□.□ (campos H, C, K, Q).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated pressure (vacuum) | -200 mbar p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Rated pressure (pressure) | 200 mbar p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Voltage | 345-415 Δ / 600-720 Y V p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Current | 9.0 Δ / 5.2 Y A p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Power | 4.0 kW p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Sound pressure level | 109 dB(A) p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Weight | approx. 109 kg p.2 ↗ | 2BH1800-1AH07, 50 Hz |
| Rated pressure (vacuum) | -160 mbar p.2 ↗ | 2BH1800-1AH07, 60 Hz |
| Rated pressure (pressure) | 160 mbar p.2 ↗ | 2BH1800-1AH07, 60 Hz |
| Voltage | 380-480 Δ / 660-720 Y V p.2 ↗ | 2BH1800-1AH07, 60 Hz |
| Current | 9.0 Δ / 5.2 Y A p.2 ↗ | 2BH1800-1AH07, 60 Hz |
| Power | 4.6 kW p.2 ↗ | 2BH1800-1AH07, 60 Hz |
| Rated pressure (vacuum) | -300 mbar p.2 ↗ | 2BH1800-1AH17, 50 Hz |
| Rated pressure (pressure) | 300 mbar p.2 ↗ | 2BH1800-1AH17, 50 Hz |
| Current | 13.3 Δ / 7.7 Y A p.2 ↗ | 2BH1800-1AH17, 50 Hz |
| Power | 5.5 kW p.2 ↗ | 2BH1800-1AH17, 50 Hz |
| Sound pressure level | 112 dB(A) p.2 ↗ | 2BH1800-1AH17, 50 Hz |
| Rated pressure (vacuum) | -320 mbar p.2 ↗ | 2BH1800-1AH27, 50 Hz |
| Rated pressure (pressure) | 430 mbar p.2 ↗ | 2BH1800-1AH27, 50 Hz |
| Current | 16.7 Δ / 9.6 Y A p.2 ↗ | 2BH1800-1AH27, 50 Hz |
| Power | 7.5 kW p.2 ↗ | 2BH1800-1AH27, 50 Hz |
| Sound pressure level | 119 dB(A) p.2 ↗ | 2BH1800-1AH27, 50 Hz |
| Protection category | IP 55 p.1 ↗ | standard motors |
| Insulation class | F p.1 ↗ | standard motors |
Operating Limits
- Max ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH1800 | Type / size: G-BH1 side channel blower, size 800 |
| 8-9 p.2 ↗ | -1 | Series / design variant prefix |
| 12-13 p.2 ↗ | 07 / 17 / 27 / 03 / 13 / 23 | Performance size: 07/03 = 4.0 kW, 17/13 = 5.5 kW, 27/23 = 7.5 kW |
| field 1 (after 2BH1800-..) p.2 ↗ | □ | Motor voltage code: H, C, K or Q |
| field 2 (after 2BH1800-..□.) p.2 ↗ | □ | Voltage range / frequency option: 1, 3, 5, 6 or 7 |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943