Technical Data Sheet — G-BH1 2BH1810 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 810: soplador de canal lateral en configuración ATEX (G-BH1 N), 50 Hz y 60 Hz, categorías ATEX 3GD, 3/2D y 3/2G; máquinas de tensión fija para 3GD/3/2D, versiones de 50 Hz o 60 Hz para 3/2G.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 400 / 690 V p.2 ↗ | 2BH1810, 50 Hz, delta/Y |
| Rated current | 20.0 / 11.6 A p.2 ↗ | 2BH1810, 50 Hz, delta/Y |
| Rated voltage | 460 V p.2 ↗ | 2BH1810, 60 Hz, delta |
| Rated current | 19.5 A p.2 ↗ | 2BH1810, 60 Hz, delta |
| Power | 14.8 hp p.2 ↗ | 2BH1810, 50 Hz |
| Power | 16.9 hp p.2 ↗ | 2BH1810, 60 Hz |
| Max. differential pressure vacuum | -153 inch H2O p.2 ↗ | 2BH1810, 50 Hz |
| Max. differential pressure vacuum | -157 inch H2O p.2 ↗ | 2BH1810, 60 Hz |
| Max. differential pressure pressure | 217 inch H2O p.2 ↗ | 2BH1810, 50 Hz |
| Max. differential pressure pressure | 205 inch H2O p.2 ↗ | 2BH1810, 60 Hz |
| Sound level | 71 dB(A) p.2 ↗ | 2BH1810, 50 Hz |
| Sound level | 71 dB(A) p.2 ↗ | 2BH1810, 60 Hz |
| Weight approx. | 399 lbs p.2 ↗ | 2BH1810, 50 Hz |
| Weight approx. | 399 lbs p.2 ↗ | 2BH1810, 60 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH1810 |
| ATEX category | 3/2G p.2 ↗ | 2BH1810, 50 Hz, Z=M71 |
| ATEX category | 3/2G p.2 ↗ | 2BH1810, 60 Hz, Z=M71 |
Operating Limits
- ATEX category availability: 3GD and 3/2D fixed voltage for 50 and 60 Hz; 3/2G only 50 Hz or 60 Hz versions p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature: 59 °F p.1 ↗
- Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
- Degree of protection: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series G-BH1 side channel blower |
| 5-7 p.2 ↗ | 810 | Size 810 |
| field 1 p.2 ↗ | 1 | Version / generation field |
| field 2 p.2 ↗ | H | Motor variant field |
| field 3 p.2 ↗ | D | Voltage connection: D = delta; G = wye (star) |
| field 4 p.2 ↗ | 1, 5, 6 | Voltage code: 1 = 230Δ/400Y (50 Hz) / 460Y (60 Hz); 5 = 500Δ (50 Hz) / 575Δ (60 Hz); 6 = 400Δ/690Y (50 Hz) / 460Δ (60 Hz) |
| field 5 p.2 ↗ | 4 | Frequency / variant field |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943