Technical Data Sheet — G-BH1 2BH1830 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 830: soplador de canal lateral en configuración ATEX (G-BH1 N), serie 2BH1830. Categorías ATEX 3GD, 3/2D y 3/2G; máquinas de tensión fija para 50 Hz y 60 Hz; 3/2G disponible solo como versiones de 50 Hz o 60 Hz.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 400 / 690 V p.2 ↗ | 2BH1830, 50 Hz, delta/Y |
| Rated current | 13,1 / 7,6 A p.2 ↗ | 2BH1830, 50 Hz, delta/Y |
| Power | 10,1 hp p.2 ↗ | 2BH1830, 50 Hz |
| Max. vacuum | -116 inch H2O p.2 ↗ | 2BH1830, 50 Hz |
| Max. differential pressure | 120 inch H2O p.2 ↗ | 2BH1830, 50 Hz |
| Sound pressure level | 79 dB(A) p.2 ↗ | 2BH1830, 50 Hz |
| Rated voltage | 460 V p.2 ↗ | 2BH1830, 60 Hz, delta |
| Rated current | 13,0 A p.2 ↗ | 2BH1830, 60 Hz, delta |
| Power | 11,5 hp p.2 ↗ | 2BH1830, 60 Hz |
| Max. vacuum | -112 inch H2O p.2 ↗ | 2BH1830, 60 Hz |
| Max. differential pressure | 100 inch H2O p.2 ↗ | 2BH1830, 60 Hz |
| Sound pressure level | 79 dB(A) p.2 ↗ | 2BH1830, 60 Hz |
| Rated voltage | 460 V p.2 ↗ | 2BH1830-1AG21-Z, 60 Hz, delta |
| Rated current | 8,9 A p.2 ↗ | 2BH1830-1AG21-Z, 60 Hz, delta |
| Power | 7,4 hp p.2 ↗ | 2BH1830-1AG21-Z, 60 Hz |
| Max. vacuum | -52 inch H2O p.2 ↗ | 2BH1830-1AG21-Z, 60 Hz |
| Max. differential pressure | 48 inch H2O p.2 ↗ | 2BH1830-1AG21-Z, 60 Hz |
| Sound pressure level | 79 dB(A) p.2 ↗ | 2BH1830-1AG21-Z, 60 Hz |
Operating Limits
- ATEX categories available: 3GD, 3/2D, 3/2G p.1 ↗
- ATEX 3/2G frequency availability: 50 Hz or 60 Hz only p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature: 59 F p.1 ↗
- Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series / type: side channel blower G-BH1 |
| 5-8 p.2 ↗ | 830 | Size 830 |
| field 1 p.2 ↗ | 1 | Voltage code: 230 delta / 400 Y (50 Hz), 460 Y (60 Hz) |
| field 1 p.2 ↗ | 6 | Voltage code: 400 delta / 690 Y (50 Hz), 460 delta (60 Hz) |
| field 1 p.2 ↗ | 5 | Voltage code: 500 delta (50 Hz), 575 delta (60 Hz) |
| field 2 p.2 ↗ | D | Connection: delta (3/2D, 3GD) |
| field 2 p.2 ↗ | G | Connection: Y (3/2G) |
| field 3 p.2 ↗ | 1 | ATEX motor variant 1 |
| field 3 p.2 ↗ | 6 | ATEX motor variant 6 |
| field 3 p.2 ↗ | 5 | ATEX motor variant 5 |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943