Hoja de datos 2BH1 943: soplador de canal lateral con convertidor de frecuencia integrado (IP55) para montaje en pared. Abarca los tipos de soplador 2BH1943-1GK36 y 2BH1943-1GK46 a 37/50/60/72 Hz, los tamaños de convertidor de frecuencia A–K (2FC4...-1□□00) y los accesorios (terminal manual MMI, cable adaptador USB, sensores de presión/vacío).

Technical Data

Parameter Value Condition
Max. differential pressure (vacuum) -250 mbar p.2 ↗ 2BH1943-1GK36, 37 Hz
Max. differential pressure (pressure) 240 mbar p.2 ↗ 2BH1943-1GK36, 37 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1943-1GK36, 37 Hz
Max. differential pressure (vacuum) -250 mbar p.2 ↗ 2BH1943-1GK36, 50 Hz
Max. differential pressure (pressure) 230 mbar p.2 ↗ 2BH1943-1GK36, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1943-1GK36, 50 Hz
Max. differential pressure (vacuum) -190 mbar p.2 ↗ 2BH1943-1GK36, 60 Hz
Max. differential pressure (pressure) 180 mbar p.2 ↗ 2BH1943-1GK36, 60 Hz
Sound pressure level 77 dB(A) p.2 ↗ 2BH1943-1GK36, 60 Hz
Rated mains voltage 330 V p.2 ↗ 2BH1943-1GK36, 72 Hz, delta
Rated motor current 79.0 A p.2 ↗ 2BH1943-1GK36, 72 Hz, delta
Rated motor power 35.0 kW p.2 ↗ 2BH1943-1GK36, 72 Hz
Max. differential pressure (vacuum) -130 mbar p.2 ↗ 2BH1943-1GK36, 72 Hz
Max. differential pressure (pressure) 120 mbar p.2 ↗ 2BH1943-1GK36, 72 Hz
Sound pressure level 82 dB(A) p.2 ↗ 2BH1943-1GK36, 72 Hz
Max. differential pressure (vacuum) -310 mbar p.2 ↗ 2BH1943-1GK46, 37 Hz
Max. differential pressure (pressure) 300 mbar p.2 ↗ 2BH1943-1GK46, 37 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1943-1GK46, 37 Hz
Max. differential pressure (vacuum) -310 mbar p.2 ↗ 2BH1943-1GK46, 50 Hz
Max. differential pressure (pressure) 280 mbar p.2 ↗ 2BH1943-1GK46, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1943-1GK46, 50 Hz
Max. differential pressure (vacuum) -270 mbar p.2 ↗ 2BH1943-1GK46, 60 Hz
Max. differential pressure (pressure) 230 mbar p.2 ↗ 2BH1943-1GK46, 60 Hz
Sound pressure level 77 dB(A) p.2 ↗ 2BH1943-1GK46, 60 Hz
Rated motor power 35.0 kW p.2 ↗ 2BH1943-1GK46, 72 Hz

Operating Limits

  • Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
  • Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH194 Side channel blower series 2BH1, size 943
8-11 p.2 ↗ 1GK3 / 1GK4 Motor/impeller variant: 1GK36 or 1GK46
converter field 1 p.2 ↗ A–K Frequency converter size (2FC4...-1□□00), see converter table
converter field 2-3 p.2 ↗ □□ Voltage/frequency option placeholders of the frequency converter