Technical Data Sheet — L-BV7 2BV7070 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Ficha técnica 2BV7 070, bomba de vacío de anillo líquido, gama de modelos L-BV7. Abarca las variantes 2BV7070-2 con códigos de tensión/frecuencia K00-1B, K00-6B, Q00-7B (50 Hz y 60 Hz, motores de eficiencia IE3 y NP).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Operating principle | Liquid ring vacuum pump p.1 ↗ | 2BV7 070 |
| Ultimate pressure | 33 mbar abs. p.1 ↗ | 97 % vacuum |
| Cavitation-free operation down to | 80 mbar abs. p.1 ↗ | |
| Pumping speed | 68 m³/h p.2 ↗ | 2BV7070, 50 Hz, 2.4 kW |
| Pumping speed | 74 m³/h p.2 ↗ | 2BV7070, 50 Hz, 3.5 kW |
| Motor power | 2,4 kW p.2 ↗ | 50 Hz, IE3 |
| Motor power | 3,5 kW p.2 ↗ | 50 Hz, IE3/NP |
| Service factor | 1,67 p.2 ↗ | 2.4 kW |
| Service factor | 1,30 p.2 ↗ | 3.5 kW IE3 |
| Service factor | 1,15 p.2 ↗ | 3.5 kW NP |
| Voltage | 190-210 V p.2 ↗ | 50 Hz, Δ |
| Voltage | 380-420 V p.2 ↗ | 50 Hz, Y |
| Voltage | 220-240 V p.2 ↗ | 50 Hz, Δ |
| Voltage | 440-480 V p.2 ↗ | 50 Hz, Y |
| Current | 16,5 A p.2 ↗ | 190-210 V Δ, 2.4 kW |
| Current | 9,3 A p.2 ↗ | 380-420 V Y, 3.5 kW |
| Current | 14,3 A p.2 ↗ | 220-240 V Δ, 2.4 kW |
| Current | 8,3 A p.2 ↗ | 380-420 V Y, 2.4 kW |
| Sound pressure level | 68 dB(A) p.2 ↗ | 2.4 kW |
| Sound pressure level | 74 dB(A) p.2 ↗ | 3.5 kW |
| Weight | 39 kg p.2 ↗ | 2.4 kW |
| Weight | 74 kg p.2 ↗ | 3.5 kW |
| Protection rating | IP55 p.1 ↗ | |
| Insulation class | F p.2 ↗ | |
| Max. back pressure | 1300 mbar atm. p.2 ↗ | 50 Hz and 60 Hz |
Operating Limits
- Min. inlet pressure (ultimate): 33 mbar abs. p.1 ↗
- Cavitation-free operation down to: 80 mbar abs. p.1 ↗
- Max. back pressure: 1300 mbar atm. p.2 ↗
- Max. water carry-over (50 Hz): 0,7 m³/h p.2 ↗
- Max. water carry-over (60 Hz): 0,85 m³/h p.2 ↗
- Protection rating: IP55 p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BV7 | Model range L-BV7 liquid ring vacuum pump |
| 5-8 p.2 ↗ | 070 | Size 070 |
| 9-10 p.2 ↗ | -2 | Variant 2 |
| field 1 p.2 ↗ | K / Q | Voltage/frequency code: K = 50/60 Hz standard ranges, Q = 475-525 V / 550-600 V |
| field 2 p.2 ↗ | 1 / 6 / 7 | Voltage connection variant (1 = 190-210 V Δ / 380-420 V Y; 6 = 220-240 V Δ / 440-480 V Y; 7 = 380-420 V Δ / 660-725 V Y) |
| field 3 p.2 ↗ | B | Version suffix |