Technical Data Sheet — G-BH1 BH1009-5 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Soplante de canal lateral G-BH1, hoja de datos BH1009-5 (2BH1100), motor monofásico; 50 Hz y 60 Hz; variantes de tensión V4 (100/200 V) y V5 (115/230 V)

Technical Data

Parameter Value Condition
Rated pressure -36 inch H2O p.2 ↗ BH1009-5, 50 Hz
Rated pressure -48 inch H2O p.2 ↗ BH1009-5, 60 Hz
Voltage 115 / 230 V p.2 ↗ BH1009-5, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1009-5, 60 Hz
Current 6,5 / 3,2 A p.2 ↗ BH1009-5, 50 Hz
Current 5,9 / 3,0 A p.2 ↗ BH1009-5, 60 Hz
Power 0,3 hp p.2 ↗ BH1009-5, 50 Hz
Power 0,3 hp p.2 ↗ BH1009-5, 60 Hz
Sound pressure level 61 dB(A) p.2 ↗ BH1009-5, 50 Hz
Sound pressure level 64 dB(A) p.2 ↗ BH1009-5, 60 Hz
Weight 24 lbs p.2 ↗ BH1009-5
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors
Frequency tolerance +/- 2 % p.2 ↗
Voltage tolerance, single-phase +/- 5 % p.2 ↗

Operating Limits

  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 59 F p.1 ↗
  • Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Voltage tolerance, single-phase machines: +/- 5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ BH1009-5 Type/size designation (2BH1100)
field after hyphen p.2 ↗ □□ Motor voltage variant: V4 = 100/200 V, V5 = 115/230 V