Technical Data Sheet — G-BH1 BH1009-6 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Fiche technique BH1009-6 (2BH1330), ventilateur à canal latéral avec moteur monophasé, 50/60 Hz, IP55, classe d'isolation F, homologué UL/CSA ; codes de commande BH1009-6AAA-BV5-BA0 et BH1009-6AAA-BV4-BA0, ainsi que les variantes de tension moteur V4 (100/200 V) et V5 (115/230 V).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Frequency | 50/60 Hz p.2 ↗ | BH1009-6 |
| Voltage | 115 / 230 V p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Current | 8,5 / 4,2 A p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Power | 0,5 hp p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Max. differential pressure, vacuum | -44 inch H2O p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Max. differential pressure, pressure | 40 inch H2O p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Sound pressure level | 58 dB(A) p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Weight approx. | 29 lbs p.2 ↗ | BH1009-6AAA-BV5-BA0, 50 Hz |
| Voltage | 115 / 230 V p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Current | 7,0 / 3,4 A p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Power | 0,6 hp p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Max. differential pressure, vacuum | -44 inch H2O p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Max. differential pressure, pressure | 40 inch H2O p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Sound pressure level | 60 dB(A) p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Weight approx. | 29 lbs p.2 ↗ | BH1009-6AAA-BV5-BA0, 60 Hz |
| Protection category | IP 55 p.1 ↗ | standard motors |
| Insulation class | F p.1 ↗ | standard motors |
| Performance tolerance | ± 10 % p.1 ↗ | performance curves |
| Frequency tolerance | +/- 2 % p.2 ↗ | maximum |
| Voltage tolerance, single phase | +/- 5 % p.2 ↗ | single phase machines |
Operating Limits
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Max. differential pressure, vacuum: -44 inch H2O p.2 ↗
- Max. differential pressure, pressure: 40 inch H2O p.2 ↗
- Frequency tolerance: +/- 2 % p.2 ↗
- Voltage tolerance, single phase: +/- 5 % p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-8 p.2 ↗ | BH1009-6 | Type / size designation (2BH1330) |
| 9-11 p.2 ↗ | AAA | Design variant field |
| 13-15 p.2 ↗ | BV5 | Motor voltage variant: V5 = 115/230 V, 50/60 Hz |
| 13-15 p.2 ↗ | BV4 | Motor voltage variant: V4 = 100/200 V, 50/60 Hz |
| 17-19 p.2 ↗ | BA0 | Design variant field |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| BH1009-6AAA-BV5-BA0 p.2 ↗ | BH1009-6AAA-BV5-BA0 | V5 | 1~ 50/60 Hz, 115/230 V, IP55, insulation class F, UL, with capacitor for continuous operation | 50 Hz: 8,5/4,2 A, 0,5 hp; 60 Hz: 7,0/3,4 A, 0,6 hp |
| BH1009-6AAA-BV4-BA0 p.2 ↗ | BH1009-6AAA-BV4-BA0 | V4 | 1~ 50/60 Hz, 100/200 V, IP55, insulation class F, UL, with capacitor for continuous operation | Electrical data not available (#NV) |
Modèles liés
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943