Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — C-KLR 80 (US)

Technical Reference Summary

Covered Models & Document Scope

Bombas de presión/vacío de la serie C-KLR, tamaños C-KLR 80 y C-KLR 140; funcionamiento a 50 Hz y 60 Hz; versiones de motor 230/400 V ±10% (C-KLR 80) y 400/690 V ±10% (C-KLR 140); accesorios ZRK, ZFP, ZMS.

Technical Data

Parameter Value Condition
Motor version voltage 230/400V ± 10% V p.2 ↗ C-KLR 80, 50 Hz
Motor version voltage 400/690V ± 10% V p.2 ↗ C-KLR 140, 50 Hz
Motor rating 4.0 kW p.2 ↗ C-KLR 80, 50 Hz
Motor rating 7.5 hp p.2 ↗ C-KLR 80, 60 Hz
Motor rating 5.5 kW p.2 ↗ C-KLR 140, 50 Hz
Motor rating 10 hp p.2 ↗ C-KLR 140, 60 Hz
Full load amperage 15.2 / 8.8 A p.2 ↗ C-KLR 80, 50 Hz
Full load amperage 21-18.8/ 9.4 A p.2 ↗ C-KLR 80, 60 Hz
Full load amperage 11.0/6.4 A p.2 ↗ C-KLR 140, 50 Hz
Full load amperage 25-24/12 A p.2 ↗ C-KLR 140, 60 Hz
Speed 80 rpm p.2 ↗ C-KLR 80, 50 Hz
Speed 83 rpm p.2 ↗ C-KLR 80, 60 Hz
Speed 353 rpm p.2 ↗ C-KLR 140, 50 Hz
Speed 374 rpm p.2 ↗ C-KLR 140, 60 Hz
Average noise level 176 dB(A) p.2 ↗ C-KLR 80, 50 Hz
Average noise level 219 dB(A) p.2 ↗ C-KLR 80, 60 Hz
Average noise level 353 dB(A) p.2 ↗ C-KLR 140, 50 Hz
Average noise level 374 dB(A) p.2 ↗ C-KLR 140, 60 Hz
Weight 176 lbs p.2 ↗ C-KLR 80, 50 Hz
Weight 219 lbs p.2 ↗ C-KLR 80, 60 Hz
Weight 353 lbs p.2 ↗ C-KLR 140, 50 Hz
Weight 374 lbs p.2 ↗ C-KLR 140, 60 Hz
Capacity 55.3 cfm p.2 ↗ C-KLR 80, 50 Hz, suction air at 0 in.Hg
Capacity 70.6 cfm p.2 ↗ C-KLR 80, 60 Hz, suction air at 0 in.Hg
Ultimate vacuum 18.1 in.Hg (gauge) p.2 ↗ C-KLR 80

Operating Limits

  • Maximum ultimate vacuum: 18.1 in.Hg (gauge) p.2 ↗
  • Maximum excess pressure: 10.2 psig p.2 ↗
  • Motor voltage tolerance: ± 10% p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.1 ↗ C-KLR Series designation (pressure/vacuum pump)
6-8 p.1 ↗ 80 / 140 Size
voltage field p.2 ↗ 230/400V ± 10% Motor voltage for C-KLR 80
voltage field p.2 ↗ 400/690V ± 10% Motor voltage for C-KLR 140
frequency field p.2 ↗ 50 Hz / 60 Hz Mains frequency
accessory field p.1 ↗ ZRK Non return valve
accessory field p.1 ↗ ZFP Vacuum tight dust separator
accessory field p.1 ↗ ZMS Motor starter

Modèles liés