Agilent Technologies 240Z GFAAS
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 240Z GFAAS

Agilent Technologies 240Z GFAAS — Atomic spectroscopy.

The 240Z GFAAS is a transverse-Zeeman graphite furnace atomic absorption spectrometer with a pyrolytic platform Omega tube and GTA 120 atomizer, configured for Pb determination in complex matrices. Its 10-step furnace program spans 95–2500 °C, with ashing to 805 °C and atomization at 2132 °C. It serves trace-metal quantification in food and water matrices, achieving Pb MDL of 2.6 ppb.

Agilent Technologies Graphite Furnace Atomic Absorption Instruments Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterSoftwareElementsLamp current, mAInert gas purity, %
240Z GFAAS Current 283.30.025.5Pb1099.99
280Z GFAAS 228.80.01method-driven, guides usCd499.99

Full specifications

Core Performance & Functional Specifications
Wavelength range 283.3 nm
Acetylene Purity 99.5 %
Elements Pb
Inert Gas Purity 99.99 %
Sample volume 20 µL
Software 5.5
Instrument mfr 280 AA
Background correction mfr transverse Zeeman Zeeman
Autosampler mfr 120
Graphite tube mfr pyrolytic platform Omega tube tube
Furnace viewing camera mfr Tube-CAM CAM
MDL in solution mfr 0.35 μg/kg
MDL in sample mfr 18 μg/kg
LOQ in sample mfr 59 μg/kg
Maximum allowable limit (Pb in condiments) mfr 1000 μg/kg
Method Detection Limit (MDL), Pb mfr 2.6 ppb
Method Detection Limit (MDL), Cd mfr 0.37 ppb
Method Detection Limit (MDL), Cr mfr 1.5 ppb
Method Detection Limit (MDL), Ni mfr 6.0 ppb
Certified value, Pb (NIST 1567b Wheat Flour) mfr 10.4 ppb
Measured value, Pb mfr 10.9 ppb
Recovery, Pb mfr 105
Certified value, Cd (NIST 1567b Wheat Flour) mfr 25.4 ppb
Measured value, Cd mfr 23.4 ppb
Recovery, Cd mfr 92
Certified value, Cr (DUWF-1 Durum Wheat Flour) mfr 23.0 ppb
Measured value, Cr mfr 21.5 ppb
Recovery, Cr mfr 93
Certified value, Ni (DUWF-1 Durum Wheat Flour) mfr 170 ppb
Measured value, Ni mfr 172 ppb
Recovery, Ni mfr 101
Matrix mfr Water Water
Modifier mfr 4
Instrumentation mfr 240 AAS
Exhaust ventilation rate mfr 6 m3/min
Exhaust fan distance from flame mfr 3 m
Acetylene supply pressure mfr 65...100 kPa
Acetylene cylinder replacement pressure mfr 700 kPa
Acetylene maximum withdrawal rate mfr 1 hour
Air supply pressure mfr 245...455 kPa
Air flow rate mfr 13.5...20 L/min
Nitrous oxide supply pressure mfr 245...455 kPa
Nitrous oxide flow rate mfr 11...16 L/min
Air purge flow rate mfr 10 L/min
Acetylene hose mfr 1.8 thread
Air hose mfr 1.8 fitting
Nitrous oxide hose mfr 1.8 fitting
Lamp capacity 240 series mfr 4 lamps
Lamp capacity 280 series mfr 8 lamps
Zeeman magnetic field mfr 0.8 peak
Minimum distance from magnet plate mfr 300 mm
Solvent specific gravity minimum mfr 0.75
Default IEEE address 55B mfr 1
Default IEEE address 240FS/240Z/280FS/280Z mfr 9
Reconfigured IEEE address for instrument #2 mfr 8
Acetylene maximum pressure mfr 105 kPa
Zeeman magnetic field peak mfr 0.8 T
Lamps accommodated (240 series) mfr 4 lamps
Lamps accommodated (280 series) mfr 8 lamps
Acetylene supply pressure (allowed range) mfr 65...100 kPa
Air supply pressure (allowed range) mfr 245...455 kPa
N2O supply pressure (allowed range) mfr 245...455 kPa
Air purge supply pressure (allowed range) mfr 245...455 kPa
Air typical flow rate mfr 13.5...20 L/min
N2O typical flow rate mfr 11...16 L/min
Air purge typical flow rate mfr 10 L/min
Gas hose internal diameter mfr 6.3 mm
Recommended acetylene delivery pressure mfr 75 kPa
Recommended air delivery pressure mfr 350 kPa
Recommended N2O delivery pressure mfr 350 kPa
Agilent 240/280 系列原子吸收(包括塞曼) mfr 5
安捷伦原子吸收光谱仪 Duo 系统的连接与配置 mfr 39
Duo 运行设置和 IEEE 电缆的连接 mfr 39
为安捷伦原子吸收 Duo 操作配置 IEEE 地址 mfr 40
配置 SPS 4 自动进样器 mfr 41
确定 SPS 4 COM 端口 mfr 42
配置软件以使用手动进样 mfr 42
启动 SpectrAA 软件 mfr 47
SpectrAA 发行说明和软件状态公告 mfr 44
安装 Tube-CAM 石墨炉摄像头选件的驱动程序 mfr 45
打印机设置 mfr 45
故障排除 mfr 45
服务安装模块 mfr 45
软件概述 mfr 47
SpectrAA 窗口 mfr 47
索引页面 mfr 47
工作表窗口 mfr 48
报告窗口 mfr 49
管理窗口 mfr 50
使用 SpectrAA 软件 mfr 50
菜单栏 mfr 50
工具栏 mfr 50
对话框 mfr 50
帮助 mfr 51
搜索帮助 mfr 51
一般信息 mfr 7
安捷伦原子吸收文档 mfr 8
验证安全状态 mfr 8
电气危险 mfr 9
热量、蒸气和烟雾 mfr 10
压缩气瓶的储存和处理 mfr 11
气体软管和接头 mfr 12
紫外线辐射 mfr 12
警告符号 mfr 13
彩色标记 mfr 14
火焰操作 mfr 15
回火 mfr 22
石墨炉和塞曼操作 mfr 26
Minimum acetylene cylinder pressure mfr 700 kPa
SRM concentration mfr 25.0 μg/L
Characteristic concentration mfr 0.85 μg/L
Instrumental Detection limit mfr 0.15 μg/L
Spike concentration mfr 25 μg/L
Dimensions, Weight & Mechanical Design
Slit Width 0.5 nm
Instrument weight mfr 50 kg
Burner slit width limit N2O/acetylene Mark 7 mfr 0.46 mm
Burner slit width limit air/acetylene Mark 7 mfr 0.54 mm
Burner slit width replacement threshold N2O/acetylene mfr 0.47 mm
Burner slit width replacement threshold air/acetylene mfr 0.54 mm
N2O/air-acetylene burner slit width limit (N2O/acetylene) mfr 0.47 mm
Burner slit width limit (air/acetylene) mfr 0.54 mm
Mark 7 burner slit width (N2O/acetylene) mfr 0.46 mm
Mark 7 burner slit width (air/acetylene) mfr 0.54 mm
Gas hose length mfr 1.8 m
N2O/acetylene burner slit width mfr 0.46 mm
Air/acetylene burner slit width mfr 0.54 mm
Characteristic Mass mfr 13.9 pg
Electrical, Power & Drive Specifications
Lamp Current 10 mA
Fuse rating 240 series mfr 4 mm
Fuse rating 280FS mfr 4 mm
Circuit breaker 240Z/280Z mfr 15 breaker
Fuse rating 240Z/280Z mfr 3.15 mm
Fuse (240 series, non-Zeeman) mfr 4 mm
Fuse (280FS, non-Zeeman) mfr 4 mm
Circuit breaker (240Z/280Z Zeeman) mfr 15 A
Fuse (240Z/280Z Zeeman) mfr 800 mm
Interfaces, Connections & Control
Acetylene hose fitting mfr 9 L/H
Air hose fitting mfr 9 UNF
N2O hose fitting mfr 3 UNF
USB 转 RS-232 接口 mfr 43
Materials, Media & Process Compatibility
Minimum distance from magnet plate (pacemakers/magnetic media) mfr 300 mm
Operating Conditions, Environment & Protection
Ash Temperature 598 °C
Atomize Temperature 1435 °C
Standards, Safety & General Data
Standard deviation, Pb mfr 1.4 ppb
Standard deviation, Cd mfr 0.22 ppb
Standard deviation, Cr mfr 2.1 ppb
Standard deviation, Ni mfr 7.5 ppb
Standard solution concentration mfr 50 μg/L

Description

Construction and series positioning

The 240Z is the Zeeman graphite furnace variant of the 240 series, distinguished from the 280Z by lamp capacity: the 240 series accommodates 4 hollow cathode lamps versus 8 on the 280 series, so the 240Z suits methods targeting a limited element set (here Pb, with Cd/Cr/Ni also demonstrated). Background correction is transverse Zeeman, and the magnet produces up to 0.8 Tesla peak at power-line frequency during the read phase. The atomizer is a GTA 120 graphite tube atomizer fitted with a pyrolytic platform Omega tube; a PSD 120 programmable sample dispenser handles sample introduction, and a Tube-CAM furnace viewing camera is specified.

Furnace behavior and method performance

Installation, gas and control specifics

The instrument requires a grounded 3-wire outlet with correct voltage setting; the 240Z/280Z use a 15 A long-delay circuit breaker plus T3.15 A H 250 V, F315 mA L 250 V, F1A L 250 V, T6.3 A L 250 V and F800 mA L 250 V fuses for 208–240 VAC. Graphite furnace operation requires inert gas (argon or nitrogen) and air; 95 % argon (or nitrogen) + 5 % hydrogen pre-mixed is allowed, but pure hydrogen must never be used. Acetylene, where the flame configuration is used, must be instrument grade ≥99.5 % at 65–100 kPa (recommended 75 kPa, never above 105 kPa). Gas hoses are 1.8 m with 6.3 mm ID; acetylene uses a red 9/16-18UNF L/H fitting, air black 9/16-18UNF, N2O blue 3/4-16UNF. Exhaust must provide at least 6 m³/min (200 cfm) with the fan at least 3 m from the flame. SpectrAA software (Base, PRO, CFR) is installed via USB-GPIB converter; the SPS 4 autosampler is configured over USB with IHelper.EXE.

Integration & Operating Notes

Electrical
Use only the specified fuse set and 15 A breaker for 208–240 VAC

The 240Z/280Z configuration requires a 15 A long-delay circuit breaker plus T3.15 A H 250 V, F315 mA L 250 V, F1A L 250 V, T6.3 A L 250 V and F800 mA L 250 V fuses. Substituting any fuse with a different type or rating compromises fire protection and voids the safety basis of the installation.

User Manual, Introduction p.35
Process Limits
Never supply pure hydrogen to the graphite furnace

The furnace accepts inert gas (argon or nitrogen) plus air, and a pre-mixed 95 % argon (or nitrogen) + 5 % hydrogen blend is permitted. Pure hydrogen must not be used under any circumstance because of explosion hazard; verify the cylinder label and regulator before connecting the furnace gas line.

User Manual, Safety p.26
Mounting
Keep magnetic media and pacemakers 300 mm from the Zeeman magnet

The transverse Zeeman magnet generates up to 0.8 Tesla peak at power-line frequency during the read phase. Pacemakers and magnetic storage media must remain at least 300 mm from the magnet plate; plan bench layout and operator access so this distance is maintained during analysis.

User Manual, Safety p.26
Mounting
Provide at least 6 m³/min exhaust with fan 3 m from the flame

Laboratory ventilation must be sized to at least 6 m³/min (200 cfm), and the exhaust fan must be located at least 3 m (10 ft) from the flame. This is a pre-installation facility requirement; undersized extraction affects both operator safety and baseline stability.

User Manual, Safety p.10
Maintenance
Do not reuse a burner head after a flashback

Following a flashback, shut off gas at the regulator, turn off the instrument, and do not reuse the burner head; contact Agilent service and inspect sample introduction components. Reusing the head risks a repeat event because the slit geometry and internal passages may be distorted.

User Manual, Safety p.25

Selection & Integration Q&A

When should I choose the 240Z over the 280Z for a graphite furnace method?

Choose the 240Z when the method targets a limited element set: the 240 series holds 4 hollow cathode lamps versus 8 on the 280 series. Both use transverse Zeeman correction and the GTA 120; the 280Z pays off only when many elements must be run without lamp changes.

What gas supply and purity does the furnace section of the 240Z require?

Inert gas (argon or nitrogen) plus air; a pre-mixed 95 % argon (or nitrogen) + 5 % hydrogen blend is allowed, but pure hydrogen is prohibited. Acetylene, if the flame configuration is used, must be ≥99.5 % instrument grade at 65–100 kPa, never above 105 kPa.

What facility and siting limits apply before the 240Z can be installed?

Exhaust must provide at least 6 m³/min (200 cfm) with the fan at least 3 m from the flame; the instrument exceeds 50 kg and needs two or more people to lift. Keep magnetic media and pacemakers 300 mm from the Zeeman magnet, which reaches 0.8 Tesla peak.

What maintenance and accessories are needed beyond the base instrument delivery?

Weekly O-ring inspection (burner head, spray chamber, plug, inlet) and window cleaning are specified, plus daily gas-supply checks. The PSD 120 dispenser, SPS 4 autosampler, Tube-CAM and UltrAA lamps are separate accessories; the SPS 4 needs USB setup via IHelper.EXE and the PC needs a USB-GPIB converter.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent 240/280 Series Atomic Absorption Spectrometers User Guide
Manual ·64 pp.
View PDF
PDF
Measuring Lead in Water
Manual ·559,4 КБ ·3 pp.
View PDF