Agilent Technologies 280Z GFAAS
Agilent Technologies 280Z GFAAS — Atomic spectroscopy.
The Agilent 280Z GFAAS is a Zeeman graphite furnace atomic absorption spectrometer configured with a GTA 120 graphite tube atomizer and PSD 120 programmable sample dispenser, as documented for cadmium determination in wheat flour. It operates with an UltrAA cadmium hollow cathode lamp at 4 mA, 0.5 nm slit, and 228.8 nm wavelength, using 10 µL sample and 5 µL chemical modifier. This modification is the application-validated 280Z platform for trace Cd in food matrices; the sibling 240Z is the alternative series member.
Agilent Technologies Graphite Furnace Atomic Absorption Instruments Series — Model Comparison & Selection
| Model | Wavelength range | Sample volume, milliliter | Software | Elements | Lamp current, mA | Inert gas purity, % |
|---|---|---|---|---|---|---|
| 280Z GFAAS Current | 228.8 | 0.01 | method-driven, guides us | Cd | 4 | 99.99 |
| 240Z GFAAS | 283.3 | 0.02 | 5.5 | Pb | 10 | 99.99 |
Full specifications
| Wavelength range | 228.8 nm |
| Analysis time | seconds |
| Consumables | none required |
| Elements | Cd |
| Inert Gas Purity | 99.99 % |
| Modifier Volume | 5 μL |
| Sample volume | 10 μL |
| Software | method-driven, guides user in each step |
| Measurement mode mfr | non-destructive multipoint mapping mapping |
| Instrument portability mfr | portable, easy-to-use use |
| Matrix mfr | Water Water |
| Chemical modifier mfr | 4 |
| Instrumentation mfr | 240 AAS |
| Hollow Cathode Lamp mfr | Cadmium Cadmium |
| Graphite tube platform mfr | Omega Omega |
| Mode mfr | Peak Area Area |
| Chemical modifier volume mfr | 1 g/L |
| Lamp type mfr | UltrAA Lamp Lamp |
| Replicates mfr | 2 |
| Wheat Flour mfr | 5.22 |
| rinse solution nitric acid concentration mfr | 2 % v/v |
| SRC nitrogen pressurization mfr | 40 bar |
| hydrogen peroxide concentration mfr | 30 |
| nitric acid concentration mfr | 60 |
| digest final volume mfr | 20 mL |
| hot block reflux duration mfr | 1 hour |
| water boil-off duration mfr | 1 hour |
| de-ionized water resistivity mfr | 18 |
| Student t factor for MDL mfr | 3.143 |
| MDL confidence level mfr | 99 % confidence |
| stability test interval mfr | after every five samples samples |
| stability test duration mfr | seven-hour period period |
| Slit Width | 0.5 nm |
| Orientation dependence mfr | independent of orientation of data collection co |
| sample weight for microwave digestion mfr | 1.0 g |
| sample weight for wet digestion mfr | 0.5 g |
| Lamp Current | 4 mA |
| Reflectance interface angle mfr | 45 ° |
| Ash Temperature (sample) | 568 °C |
| Atomization Temperature | 2100 °C |
| Atomize Temperature (sample) | 1577 °C |
| Ash Temperature (standard) | 570 °C |
| Atomize Temperature (standard) | 1533 °C |
| Standard Solution | 2.50 Cd |
| Standard Reference Material mfr | 1 Cd |
| bulk standard Pb concentration mfr | 100 μg/L |
| bulk standard Cd concentration mfr | 5 μg/L |
| bulk standard Cr concentration mfr | 20 μg/L |
| Pb MDL standard concentration mfr | 0.3 ppb |
| Cd MDL standard concentration mfr | 0.05 ppb |
| Cr MDL standard concentration mfr | 0.1 ppb |
| Ni MDL standard concentration mfr | 0.5 ppb |
| stability test Pb standard concentration mfr | 5 standard |
Description
Construction and series positioning
- The 280Z GFAAS is a Zeeman-effect graphite furnace AAS instrument; the verified application configuration pairs it with the GTA 120 Graphite Tube Atomizer and PSD 120 Programmable Sample Dispenser.
- Within the series, the 280Z is the model documented for the four-Chinese-national-method grain workflow (Pb, Cd, Cr, Ni); the 240Z GFAAS is the sibling variant with no verified differentiating specifications in the supplied facts.
- The documented cadmium method uses an UltrAA cadmium hollow cathode lamp, an Omega graphite tube platform, and peak-area measurement mode.
Behavior under load and in the furnace program
- The verified Cd temperature program spans ash temperatures of 568 °C (sample) and 570 °C (standard) and atomization temperatures of 2100 °C (setpoint), 1577 °C (sample) and 1533 °C (standard); these are program/measurement values, not instrument ratings.
- The method uses 10 µL sample, 5 µL chemical modifier, 2 replicates, and a 2.50 Cd standard solution; the inert gas purity requirement is 99.99 %.
- The supplied facts list no digitized curve points, so no calibration slope or detection-limit behavior can be stated.
Control, installation and operation
- Software is method-driven and guides the user step by step; results are reported on-board as immediate color-coded output.
- The digest describes the workflow as non-destructive multipoint mapping independent of data-collection orientation, with a 45° reflectance interface angle and water matrix.
- No electrical, interface, environmental or compliance specifications were verified for this model; those integration details must come from the site manual.
Integration & Operating Notes
The documented Cd method specifies 99.99 % inert gas purity. Lower-purity argon or nitrogen introduces oxygen and moisture into the graphite tube, affecting ash/atomization behavior and the blank; verify the gas supply certificate before running the temperature program.
The software guides the operator through each step of the method rather than requiring manual program entry. Plan operator training around the method workflow, and confirm that the installed software revision matches the method file used for the grain application.
Selection & Integration Q&A
Choose the 280Z when the method is the documented Zeeman GFAAS grain workflow with GTA 120 atomizer and PSD 120 dispenser. The supplied facts give no differentiating specifications for the 240Z, so compare the two only against verified site requirements, not assumed performance differences.
The verified configuration pairs the 280Z with a GTA 120 Graphite Tube Atomizer and PSD 120 Programmable Sample Dispenser, an UltrAA cadmium hollow cathode lamp run at 4 mA, an Omega graphite tube platform, and 99.99 % inert gas. Electrical and interface requirements are not in the supplied facts.
The supplied facts contain no mounting, clearance, ambient temperature or humidity specifications for this model. The digest only notes that data collection is independent of orientation and describes a 45° reflectance interface angle; confirm installation limits from the site manual before siting.