Agilent Technologies GPC/SEC Systems, Macromolecular Analysis and Solution
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies GPC/SEC Systems, Macromolecular Analysis and Solution

Agilent Technologies GPC/SEC Systems, Macromolecular Analysis and Solution — Liquid chromatography.

The Agilent GPC/SEC System is a dedicated gel-permeation/size-exclusion chromatography configuration within the InfinityLab HPLC series, built around a 4.6 mm internal-diameter column format and a typical flow rate of 1 mL/min. It is distinguished from analytical HPLC and 2D-LC siblings by its macromolecular-analysis purpose, supporting up to 6144 samples in automated operation with 9 ppm carryover. It serves as the separation engine for polymer molecular-weight distribution and solution-size characterization workflows.

Agilent Technologies HPLC Systems Series — Model Comparison & Selection

Model Max pressure, megapascalCarryover, %Column inner diameter, mmMaximum pressure, barSample capacityTypical flow rate, mL/min
GPC/SEC Systems, Macromolecular Analysis and Solution Current —9×10⁻⁴4.6130061441
2D-LC System 1309×10⁻⁴4.6130061441
Analytical HPLC and UHPLC Systems —9×10⁻⁴4.6130061441
Preparative HPLC Systems, InfinityLab LC Purification Solutions —9×10⁻⁴4.6130061441

Full specifications

Core Performance & Functional Specifications
Carryover 9 ppm
Maximum pressure 1300 bar
Sample Capacity 6144 samples
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Dimensions, Weight & Mechanical Design
Column Inner Diameter 4.6 mm

Description

Construction and series positioning

Behavior and media

Installation, control and operation

Integration & Operating Notes

Process Limits
Carryover budget is 9 ppm between injections

With 9 ppm carryover stated for this configuration, method sequences that quantify trace high-molecular-weight shoulders should include blank injections at the start and end of each batch to confirm the wash performance of the autosampler remains within this budget.

Factory Specification Sheet
Control & I/O
Electrical and interface data are not in the supplied documents

The attached brochures describe the InfinityLab LC portfolio generally and print no model-specific voltage, current, communication protocol or software-version facts for this GPC/SEC system. Obtain these from the model-specific user manual before specifying power, network or controller hardware.

InfinityLab LC brochures (portfolio scope only
Maintenance
No service interval is documented for this exact model

The supplied document digests contain no maintenance schedule, error-code list or consumable part numbers for this GPC/SEC configuration. Service intervals and replacement parts must be taken from the model-specific manual; do not infer them from the 2D-LC, Bio LC or purification brochures.

Document digests, scope statements

Selection & Integration Q&A

When should I choose this GPC/SEC configuration instead of the Analytical HPLC/UHPLC or 2D-LC siblings?

Pick this one for macromolecular/solution SEC work at 4.6 mm column ID and ~1 mL/min with 6144-sample capacity and 9 ppm carryover. Choose the analytical/UHPLC sibling for small-molecule assays, the 2D-LC sibling for orthogonal multidimensional separations, and the Bio HPLC sibling for bio-inert flow paths.

What must adjacent pump, autosampler and detector hardware satisfy for this configuration?

They must support the verified 4.6 mm column format at a typical 1 mL/min and keep system carryover at the stated 9 ppm. The supplied brochures print no voltage, protocol or fitting data for this model, so pump/detector compatibility and connection details must be confirmed against the model-specific manual.

What mounting, environment and duty-cycle limits apply to this system?

The supplied facts and document digests contain no ambient temperature, humidity, bench-load or duty-cycle figures for this GPC/SEC model. The 6144-sample capacity implies long unattended runs, but environmental and continuous-operation limits must be read from the model-specific user manual before installation.

What maintenance and accessories are defined for this model, and what is not included?

No service intervals, error codes, cables or consumable part numbers are documented in the supplied digests; those brochures cover 2D-LC, Bio LC and purification portfolios only. Maintenance schedule and any cables, fittings or columns must be specified from the model-specific manual and ordering information.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent 1260 Infinity II Bio-Inert LC System - Span the Spectrum of Bio LC
Brochure ·2,6 МБ ·16 pp.
View PDF