Agilent Technologies Cold Cathode Gauge Tube 525, High Vacuum (HV) Gauge
Agilent Technologies Cold Cathode Gauge Tube 525, High Vacuum (HV) Gauge — Vacuum technologies.
The Agilent Cold Cathode Gauge Tube 525 is a high-vacuum (HV) cold cathode ionization gauge tube for pressure measurement in the high-vacuum range. It is the HV variant within Agilent's cold cathode gauge family, distinguished from the 531 thermocouple (rough vacuum) and 571/572 Bayard-Alpert (UHV) siblings by its cold cathode discharge principle. It serves as the sensor element in vacuum system pressure monitoring and control loops.
Agilent Technologies Vacuum Transducers Series — Model Comparison & Selection
| Model | Measurement range | Atomic mass unit, grams | Electron charge, coulomb | Molar volume, liters | Max pressure, megapascal | Sensitivity |
|---|---|---|---|---|---|---|
| Cold Cathode Gauge Tube 525, High Vacuum (HV) Gauge Current | — | 1.66 | 1602 | 22.41 | — | — |
| 531 Thermocouple Gauge, Rough Vacuum Pressure Measurement | — | 1.66 | 1602 | 22.41 | — | — |
| 571 Bayard-Alpert Gauge Tube | -3...2 | 1.66 | 1602 | 22.41 | 1.33×10⁻⁴ | 17 |
| 572 Tungsten Bayard-Alpert Gauge | -3...2 | 1.66 | 1602 | 22.41 | -3...2 | — |
| Hot Filament Gauge MBA2-201, Ionization BA Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| IMG-100 Inverted Magnetron Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| IMG-300 UHV Inverted Magnetron Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| UHV-24/UHV-24p | 1 | 1.66 | 1602 | 22.41 | — | 25 |
Full specifications
| Electron Charge | 1.602 coulomb |
| Molar Volume | 22.41 liters |
| Acceleration due to gravity mfr | 9.8066 |
| Angstrom unit mfr | 10 m |
| Avogadro's number mfr | 6.02214076 |
| Boltzmann's constant mfr | 1.38064852 |
| Equivalent of heat mfr | 4.185 |
| Natural log base mfr | 2.7183 |
| Velocity of light mfr | 2.9979 |
| Velocity of sound mfr | 343 |
| Magnetic flux density mfr | 1 |
| Pressure conversion mfr | 1 Torr |
| Pumping speed conversion mfr | 1 L/s |
| Throughput conversion mfr | 1 cc/sec |
| Outgassing rate mfr | 2 |
| Atomic Mass Unit | 1.6605 grams |
| Standard pressure mfr | 101325 Pa |
Description
Construction and series positioning
The 525 is a cold cathode gauge tube, a sensor-only device that requires an external controller for bias voltage and current measurement. Within the Agilent vacuum transducer series, it occupies the high-vacuum slot: the 531 thermocouple gauge covers rough vacuum, the 571/572 Bayard-Alpert tubes are hot-cathode UHV sensors, and the 525 cold cathode tube is the HV-range ionization sensor. No electrical, mechanical, or performance specifications for the 525 itself are present in the verified facts; the matched spec rows are physical constants and the extra specs are conversion factors, not instrument ratings.
Behavior and measurement principle
Cold cathode gauges operate by maintaining a glow discharge in a magnetic field; the discharge current is a function of pressure. Because the discharge is sustained without a hot filament, the tube is not damaged by accidental exposure to higher pressures, unlike hot-cathode Bayard-Alpert tubes. The verified facts contain no curve points, no pressure range, and no calibration data for the 525, so no response behavior can be stated here.
Installation, connection, and control
The document digests cover Agilent's broader vacuum portfolio and a formulas/tables reference booklet; neither contains 525-specific installation, connection, or control facts. The tube must be connected to a compatible cold cathode controller (not included and not identified in the facts) and mounted to the vacuum chamber via the appropriate flange (flange type not stated in the facts). No operating instructions, pinouts, or control settings are available in the verified material.
Integration & Operating Notes
The 525 is a gauge tube only and does not produce a usable output without an external cold cathode controller that supplies the high-voltage discharge and reads the ionization current. The verified facts do not name a compatible controller model, so the controller must be selected from Agilent's cold cathode gauge controller line and confirmed against the tube's connector.
The verified facts do not state the 525's flange type, orientation constraints, or clearance requirements. The mounting interface must be confirmed from the product datasheet or instruction manual before chamber design is frozen, since a mismatch would require a flange adapter or a different tube variant.
Selection & Integration Q&A
Choose the 525 for high-vacuum measurement where the filament-free cold cathode discharge is preferred, e.g. where accidental higher-pressure exposure is possible. The 531 is for rough vacuum; the 571/572 hot-cathode Bayard-Alpert tubes are for UHV. The verified facts give no pressure ranges for the 525, so confirm the overlap with the 571/572 range before selecting.
The 525 is a tube only: it needs a compatible cold cathode controller to supply the discharge voltage and read the ionization current, plus the correct flange and cable. The verified facts do not name a controller model or cable part number, so these must be confirmed from Agilent's cold cathode gauge controller documentation and ordering information.
The verified facts contain no mounting orientation, clearance, temperature, or duty-cycle data for the 525. These limits must be taken from the 525 instruction manual before installation; the general vacuum reference booklet (5994-5366EN) provides only formulas and conversion tables, not instrument-specific limits.
The verified facts list no maintenance interval, spare parts, or included accessories for the 525. Treat the controller, cable, and flange hardware as separate items and confirm the spare-tube and service policy from Agilent's ordering information; the portfolio leaflet 5994-8433EN covers service options only at a general level.