Agilent Technologies 5300 Fragment Analyzer
Agilent Technologies 5300 Fragment Analyzer — Automated electrophoresis.
The 5300 Fragment Analyzer is a 48-capillary automated electrophoresis system for sizing, quantification and integrity assessment of IVT mRNA drug substances and LNP-encapsulated mRNA drug products. It resolves fragments differing by ~8 bp at 500 bp and sizes DNA from 100 to 6,000 bp, with sensitivity down to 5 pg/µL. It serves as the CQA workhorse between the lower-throughput 5200 and the ultra-high-throughput 5400 in the Fragment Analyzer series.
Agilent Technologies Fragment Analyzer Systems Series — Model Comparison & Selection
| Model | Measurement range | Plate capacity | Average sizing of 2 200 nt ivt mrna, nt | Lower marker size of hs rna kit, nt | Maximum ivt mrna sample size analyzed, nt | Sample volume per well, microliter |
|---|---|---|---|---|---|---|
| 5300 Fragment Analyzer Current | — | — | 2370 | 15 | 6000 | — |
| 5200 Fragment Analyzer | — | — | 2370 | 15 | 6000 | 2 |
| Fragment Analyzer Capillary Arrays | — | 12 | — | — | — | 2 |
| RNA QC, DNA QC, Fragment Analyzer | — | 12 | — | — | — | 2 |
| Ultra-high-throughput fragment analysis 5400 Fragment Analyzer | 0.5 | nine plates | 2370 | 15 | 6000 | — |
Full specifications
| Sensitivity | 5 pg/µL |
| Average Sizing Of 2,200 Nt Ivt Mrna | 2370 nt |
| Lower Marker Size Of Hs Rna Kit | 15 nt |
| Maximum Ivt Mrna Sample Size Analyzed | 6000 nt |
| Resolution | 5 milligram |
| Sample types analyzed mfr | IVT mRNA drug substances and LNP-encapsulated IV |
| Additional sample mfr | 1 |
| Instrument mfr | 5300 system |
| LNP disruption mfr | varying amounts of surfactant surfactant |
| Surfactant levels tested mfr | 20 |
| Sample concentration range mfr | 1 ng/μL |
| Sizing range mfr | 100...5,000 bp |
| Extended method mfr | Method BE BE |
| Dilution ratios tested mfr | 1 |
| Sizing accuracy mfr | 15 |
| Quantitative range, smears mfr | 100...5,000 pg/μL |
| Quantitative range, fragments mfr | 5...500 pg/μL |
| Quantitative accuracy mfr | 25 |
| Quantitative range mfr | 10...1,000 pg/μL |
| DNA sizing range mfr | 100 bp |
| Separation resolution mfr | 8 bp |
| DNA sizing precision mfr | 2 % CV |
| DNA sizing accuracy mfr | 5 better |
| DNA fragment concentration range mfr | 0.005 DNA |
| IVT mRNA drug product sizes analyzed mfr | 2,200 nt |
| Surfactant concentrations tested for LNP disruption mfr | 20 |
| Sample concentration range assessed mfr | 1 ng/μL |
| Dilution ratios assessed with extended method mfr | 1 |
| DNA sizing precision1 mfr | 2 % CV |
| DNA sizing accuracy1 mfr | 5 better |
| Intercalating Dye volume (48 samples) mfr | 2.5 μL |
| Gel volume (48 samples) mfr | 25 mL |
| Intercalating Dye volume (96 samples) mfr | 4.0 μL |
| Gel volume (96 samples) mfr | 40 mL |
| Intercalating Dye volume (144 samples) mfr | 5.5 μL |
| Gel volume (144 samples) mfr | 55 mL |
| Intercalating Dye volume (192 samples) mfr | 7.0 μL |
| Gel volume (192 samples) mfr | 70 mL |
| Intercalating Dye volume (240 samples) mfr | 8.5 μL |
| Gel volume (240 samples) mfr | 85 mL |
| Inlet Buffer fill volume per well mfr | 1.0 mL/well |
| Capillary Storage Solution fill volume per well mfr | 100 μL/well |
| Marker plate fill volume per well mfr | 30 μL/well |
| MDK DNA Ladder volume mfr | 24 μL |
| disruption time mfr | 20 minutes |
| sizing accuracy specification mfr | 15 % error |
| sizing precision specification mfr | 5 % CV |
| HS NGS kit sizing range mfr | 100...6,000 bp |
| HS D5000 ScreenTape sizing range mfr | 100...5,000 bp |
| HS D5000 limit of detection mfr | 5 pg/uL |
| SPRI bead cleanup ratio mfr | 0.8 x |
| spike-in fragment concentration mfr | 50 pg/μL |
| library concentration mfr | 500 pg/μL |
| Peak Width | 40 seconds |
| Sample sizes (nucleotide length) mfr | 2,200 nt |
| minimum peak height mfr | 10 RFU |
| standard sizing upper limit mfr | 6000 nt |
Description
Construction and series positioning
- The 5300 is the 48-capillary configuration of the Fragment Analyzer line; the 5200 is the lower-capillary-count sibling, the 5400 the ultra-high-throughput variant, and capillary arrays are consumable sub-assemblies rather than instruments.
- The 48-capillary array is the format referenced throughout the CRISPR Discovery Gel Kit quick guide, with gel/dye volumes scaled from 48 to 240 samples (2.5 µL dye + 25 mL gel for 48 samples up to 8.5 µL + 85 mL for 240).
- Method selection is array-specific: the CRP-910-(33 or 55) – CRISPR Discovery method is chosen in the Fragment Analyzer software for the 33 or 55 array variant.
Behavior across assays and media
- DNA sizing spans 100–6,000 bp with 8 bp separation resolution at 500 bp on the 33-55 array; sizing precision is 2% CV and accuracy ±5% or better when standards are prepared in 1x TE buffer.
- DNA fragment input range is 0.005–2 ng/µL, adjustable by dilution; IVT mRNA drug substance and LNP-encapsulated drug product are both supported, with LNP disruption achieved by varying surfactant concentration.
- IVT mRNA samples up to 6,000 nt are analyzed; the HS RNA Kit lower marker is 15 nt.
Installation, connection and operation
- Runs are queued from the Fragment Analyzer software by selecting the assay method and entering tray and sample information; one sample well per separation is typically dedicated to the ladder.
- The ladder (MDK DNA Ladder) is loaded undiluted, 24 µL into well D12 or H12, and marker wells receive 30 µL/well plus a mineral oil overlay to prevent evaporation.
- Inlet buffer (1x 930 dsDNA Inlet Buffer) is filled 1.0 mL/well in rows A–D and replaced daily; capillary storage solution is filled 100 µL/well in rows A–D of sample tray 3 and replaced every 2–4 weeks.
Integration & Operating Notes
Samples outside the supported input concentration range must be diluted before loading; the stated sizing precision (2% CV) and accuracy (±5%) are only valid for standards initially prepared in 1x TE buffer, so buffer mismatch will degrade results even when concentration is in range.
The CRP-910-(33 or 55) – CRISPR Discovery method must be selected from the software dropdown to match the 33 or 55 array variant; running the wrong method for the installed array will produce invalid sizing and should be treated as a run-setup interlock before queuing samples.
Gel/dye mixture volumes are tabulated from 48 samples (2.5 µL dye + 25 mL gel) to 240 samples (8.5 µL dye + 85 mL gel); preparing the wrong scale wastes kit reagents or starves the array, and one well per separation is typically reserved for the ladder.
Selection & Integration Q&A
Pick the 5300 when your throughput fits a 48-capillary array and you need IVT mRNA/LNP CQA plus DNA sizing to 6,000 bp at 8 bp resolution near 500 bp. The 5200 suits lower throughput; the 5400 is the ultra-high-throughput variant for larger batch campaigns.
You need the 48-capillary array, the assay kit (e.g., CRISPR Discovery Gel Kit DNF-810 with gel, intercalating dye, inlet buffer, conditioning solution, markers, ladder, dilution buffer, mineral oil), a marker plate with mineral oil overlay, and the matching software method for the 33 or 55 array.
Inlet buffer must be replaced daily and capillary storage solution every 2–4 weeks; marker wells need a mineral oil overlay to prevent evaporation. Gel/dye mixture must be prepared fresh and scaled to sample count, so plan runs around daily buffer refresh rather than multi-day unattended campaigns.
Budget daily inlet buffer replacement (1.0 mL/well, rows A–D), capillary storage solution refresh every 2–4 weeks (100 µL/well, tray 3), and periodic capillary array replacement. The kit lists one item sold separately; the MDK DNA Ladder is used undiluted at 24 µL in well D12 or H12.