Agilent Technologies Compact FTIR Spectrometer, At-side FTIR Analyzer
Agilent Technologies Compact FTIR Spectrometer, At-side FTIR Analyzer — Molecular spectroscopy.
The Agilent 4500 Series FTIR is a rugged portable mid-IR spectrometer in an IP54 housing with an internal four-hour battery, positioned between the 4200 FlexScan and the lab-oriented 5500 Series. It delivers full spectra in under two minutes and connects via USB or Bluetooth, making it suited to at-site identification and nondestructive testing where a benchtop instrument cannot be brought.
Agilent Technologies FTIR Compact Portable Systems Series — Model Comparison & Selection
| Model | Wavelength range | Weight, kg | Analysis time, min | Dimensions, mm | Power supply | Protection rating |
|---|---|---|---|---|---|---|
| Compact FTIR Spectrometer, At-side FTIR Analyzer Current | — | 3.6 | less than two minutes | 203 | battery or mains | 54 |
| 4200 FlexScan | 4000...650 | — | — | — | — | — |
| 4500 Portable FTIR Spectrometer, Rugged Non-Lab Analyzer | — | 3.6 | less than two minutes | 203 | battery or mains | 54 |
| Handheld FTIR, Mobile Nondestructive Testing | — | 2.27 | — | — | — | — |
Full specifications
| Analysis time | less than two minutes |
| Dimensions | 20.3 cm |
| Computer connection mfr | USB or Bluetooth Bluetooth |
| Weight | 3.6 kg |
| Footprint mfr | 4 paper |
| Power supply | battery or mains |
| Battery operating time mfr | four-hour h h |
| Protection rating | 54 |
Description
Construction and series positioning
- The 4500 Series is the field-rugged member of Agilent's portable FTIR family: an IP54-rated enclosure with an internal battery, distinct from the 4200 FlexScan and the 5500 Series, which the source document describes as intended for laboratory, QA/QC and field use rather than as a sealed portable.
- The handheld FTIR variant is a separate sibling; this card covers the 4500 Series portable analyzer only.
Operating behavior
- Analysis time is stated as less than two minutes per measurement, which sets the practical duty cycle for at-site screening: the instrument is not intended for continuous high-throughput laboratory queues.
- The internal battery provides four hours of operating time, so a working session is bounded by that figure unless mains power is available; the unit accepts either battery or mains supply.
Connection and operation
- Computer connection is by USB or Bluetooth. The Bluetooth path removes the cable between instrument and host, which matters for at-site use where the operator moves between sampling points.
- No control software, spectral library or accessory set is specified in the verified facts; these must be confirmed against the full instrument manual before integration.
Integration & Operating Notes
The internal battery is rated for four hours of operation, so a full working day at site requires either mains supply at the measurement location or a planned break for recharging. The instrument accepts battery or mains, but the verified facts do not state charging time, so recharge scheduling must be confirmed against the manual.
The IP54 rating protects against dust ingress and water splashing but does not permit immersion or washdown. At-site deployment near liquid spills or in heavy rain requires the instrument to be shielded; the rating should not be read as a general outdoor or wet-environment qualification.
The instrument offers USB and Bluetooth links to a host computer. The verified facts do not name the control or spectral-analysis software, nor whether Bluetooth pairing is restricted to specific host platforms, so the software stack and host compatibility must be confirmed before the instrument is specified into a workflow.
Selection & Integration Q&A
Pick the 4500 when the measurement must be taken at site: it is the IP54, battery-powered member with a four-hour internal battery. The 5500 Series is described for lab, QA/QC and field use; the 4200 FlexScan is a separate sibling whose specs are not given here, so compare it only against confirmed data.
A host computer linked by USB or Bluetooth; the instrument runs on battery or mains. The verified facts do not name the control software, Bluetooth host restrictions or cable accessories, so these must be confirmed from the manual before the host platform is fixed.
The verified facts list no maintenance schedule, service intervals, cables, software licences or consumables in the base delivery. Battery replacement interval, calibration/service requirements and the accessory set must be obtained from the full 4500/5500 Series manual before commissioning.