Agilent Technologies Quadrupole Time-of-Flight GC/MS, Mass Screening GC/Q-TOF
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Quadrupole Time-of-Flight GC/MS, Mass Screening GC/Q-TOF

Agilent Technologies Quadrupole Time-of-Flight GC/MS, Mass Screening GC/Q-TOF — Gas chromatography mass spectrometry gc ms.

The Agilent 7250 Series GC/Q-TOF is a quadrupole time-of-flight GC/MS configured for accurate-mass screening (50–950 m/z) with 70 eV EI at a 200 °C source and 150 °C quadrupole. It is distinguished within the GC/MS series by accurate-mass, retention-time-locked library workflows (900+ entries) rather than single-quadrupole or triple-quadrupole targeted analysis. It serves nontargeted and targeted screening of complex extracts in metabolomics, natural-products and E&L work.

Agilent Technologies GC MS Instruments Series — Model Comparison & Selection

Model Pumping speed, m³/hCarrier gasTransfer line temperature, °CSample volume, milliliterIon source temperature, °CAnalysis time, min
Quadrupole Time-of-Flight GC/MS, Mass Screening GC/Q-TOF Current —1.5280———
5977C GC/MSD 1Hydrogen2303×10⁻⁴2307.5
7000E GC/TQ 6×10⁻⁵Helium3000.00228010
7010D GCMS —Helium3000.002280—

Full specifications

Core Performance & Functional Specifications
Carrier gas 1.5 Helium
Electron Energy 70 eV
Spectral Acquisition Rate 50 Hz
Wavelength range 50...1,000 m/z
Column mfr -5 μm
Oven program mfr 50 minutes
Source mode mfr 70 eV
Library entries mfr 900 entries
Library type mfr accurate mass retention time locked EI library l
Compounds identified in mouse tissues mfr 200 compounds
Compounds identified in plasma samples mfr 139...168 compounds
Retention time range mfr 6.48...29.48 min
Match score range mfr 80.3...99.3
Library score range mfr 80...99.9
Modulation period mfr 6 s
Cold jet flow mfr 13 L/min
Hot jet duration mfr 320 ms
Dimensions, Weight & Mechanical Design
Mass range 50...950 m/z
Operating Conditions, Environment & Protection
Quadrupole Temperature 150 °C
Source Temperature 200 °C
Transfer Line Temperature 280 °C
Inlet mfr 310 °C
Transferline mfr 280 °C

Description

Construction and series positioning

Behavior and operating envelope

Installation and operation

Integration & Operating Notes

Cooling & Media
GC×GC operation needs modulator jets set as a matched set

For 2D GC×GC the documented conditions are a 6 s modulation period, 13 L/min cold jet flow, 300 °C hot jet and 320 ms hot jet duration. These are coupled settings; changing the modulation period without re-checking jet flows and durations will degrade peak capacity and library match quality.

Application Note 5994-5468EN, GC×GC conditions

Selection & Integration Q&A

When should I choose this Q-TOF model instead of the 5977C GC/MSD or the 7000E GC/TQ?

Pick the Q-TOF for accurate-mass nontargeted screening and library identification (900+ entry accurate-mass EI library). The 5977C single quadrupole suits routine targeted work; the 7000E and 7010D triple quadrupoles suit high-sensitivity targeted MRM quantitation.

What GC and modulator hardware does the documented GC×GC configuration require?

The application note describes the Q-TOF coupled to an Agilent 7890B GC with a modulator set to a 6 s period, 13 L/min cold jet, 300 °C hot jet and 320 ms hot jet duration. Plan the GC, modulator and jet gas supply as part of the system, not as an accessory.

What is not included in the base delivery according to the supplied documents?

The documents are application notes only; they do not list a base scope. The GC (e.g. 7890B), GC×GC modulator and jet gases, the accurate-mass PCDL library, and consumables such as the -5 µm column are described as separate items and must be ordered and specified separately.