Agilent Technologies Activated Phycobiliproteins
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Activated Phycobiliproteins

Agilent Technologies Activated Phycobiliproteins — Biomolecules conjugation synthesis purification.

Activated phycobiliproteins are native or cross-linked phycobiliprotein preparations (RPE, APC, cross-linked APC, C-PC, PerCP) supplied in a chemically activated form for direct covalent conjugation to antibodies, proteins, or other ligands. The tetrameric 52 kDa form carries an excitation maximum at 566 nm and emission maximum at 575 nm, with a specific activity of 14.0 U/mg HABA dye and solubility at 50 mg/mL. This modification is selected when the user performs in-house conjugate synthesis rather than purchasing pre-made streptavidin-phycobiliprotein conjugates.

Agilent Technologies Phycobiliprotein Series — Model Comparison & Selection

Model Emission maximum, nmExcitation maximum, nmMolecular weight tetramer size, kDaSolubility concentration, mg/mLSpecific activity haba dye, U/mg
Activated Phycobiliproteins Current 575566525014
Phycobiliproteins 575566525014

Full specifications

Core Performance & Functional Specifications
Emission Maximum 575 nm
Excitation Maximum 566 nm
Solubility Concentration 50 mg/mL
Specific Activity (haba Dye) 14.0 U/mg
Extinction coefficient mfr 240
PJRS301*; PJRS20; PJRS34 mfr Large Large
PJRS25**; PJRS27 mfr Medium Medium
PJ39S mfr Small Small
Streptavidin-Agarose bead size distribution mfr 75...300 microns
Streptavidin-Agarose pH stability range mfr 4...11
Streptavidin-Agarose streptavidin content mfr 1 beads
HRP conjugate stabilizer dilution mfr 1000 fold
AP conjugate stabilizer dilution mfr 1000 fold
RPE conjugation kit antibody capacity mfr 1 mg
RPE conjugation kit minimum scale mfr 50 antibody
RPE conjugation time mfr as little as two hours hours
Dimensions, Weight & Mechanical Design
Molecular Weight (tetramer Size) 52 kDa

Description

Construction and series positioning

Behavior in conjugation chemistry

Installation, connection and operation

Integration & Operating Notes

Process Limits
Do not exceed 50 mg/mL working solubility

The stated solubility of 50 mg/mL is the ceiling for dissolving the activated phycobiliprotein before conjugation; exceeding it risks incomplete dissolution and unreacted activated dye in the final conjugate, which will raise background in the assay.

Factory Specification Sheet
Process Limits
Match excitation source to the 566 nm maximum

The excitation maximum is 566 nm and the emission maximum 575 nm; the illumination or laser line and the emission filter set must be chosen around these values, otherwise the 52 kDa tetramer will be poorly excited and the conjugate signal will be weak.

Factory Specification Sheet
Maintenance
Verify activity against the HABA 14.0 U/mg basis

Specific activity is expressed as 14.0 U/mg HABA dye, the same activity scale used for SA10 native streptavidin and SA26 recombinant streptavidin-plus; when qualifying a lot, run the HABA assay on this basis rather than assuming equivalence to other phycobiliprotein lots.

Agilent streptavidin and phycobiliprotein conjugates product digest
Control & I/O
Conjugation protocol is not in the attached digest

The attached document digest lists the activated phycobiliproteins only as a portfolio item and provides no section-level or actionable engineering facts; the conjugation ratio, buffer and quenching steps must be taken from the full manual or kit instructions, not inferred from this card.

Agilent streptavidin and phycobiliprotein conjugates product digest

Selection & Integration Q&A

When should I choose activated phycobiliproteins instead of the RPE or APC conjugate siblings?

Choose the activated phycobiliprotein when you will attach your own antibody or ligand and need the 566/575 nm tetramer as a building block. Choose RPE Conjugates or Allophycocyanin (APC) Conjugates when a pre-made reagent is acceptable and no in-house conjugation step is wanted.

What adjacent reagents and activity basis must match this activated phycobiliprotein in a conjugate workflow?

The 14.0 U/mg HABA dye activity basis is shared with SA10 native streptavidin and SA26 recombinant streptavidin-plus, so streptavidin partners should be qualified on the same HABA scale. The 50 mg/mL solubility sets the working concentration; keep the 52 kDa tetramer within that limit during coupling.

What mounting and duty-cycle limits apply to this activated phycobiliprotein?

No mounting, environment or duty-cycle limits are stated in the supplied facts; the only operating limits given are the 50 mg/mL solubility and the 566 nm excitation / 575 nm emission maxima. Consult the full manual for storage and handling conditions before use.

What maintenance and accessories are required, and what is not included in base delivery?

The base delivery is the activated phycobiliprotein itself; conjugation kits, streptavidin-HRP/AP conjugates and stabilizers are separate catalog items in the same portfolio. Lot qualification should use the HABA assay at 14.0 U/mg. No service interval is stated in the supplied facts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent Streptavidin, Phycobiliprotein and Conjugate Products
Brochure ·1,8 МБ ·12 pp.
View PDF